Trial Tibial Inserts May Result in Different Knee Kinematics from Final Poly Inserts in Total Knee Arthroplasty.

IF 1.7 Q2 ORTHOPEDICS Orthopedic Research and Reviews Pub Date : 2021-06-28 eCollection Date: 2021-01-01 DOI:10.2147/ORR.S309995
Sahil Prabhnoor Sidhu, Brent Lanting, Paul Kelly, Edward Vasarhelyi, Ryan Willing
{"title":"Trial Tibial Inserts May Result in Different Knee Kinematics from Final Poly Inserts in Total Knee Arthroplasty.","authors":"Sahil Prabhnoor Sidhu,&nbsp;Brent Lanting,&nbsp;Paul Kelly,&nbsp;Edward Vasarhelyi,&nbsp;Ryan Willing","doi":"10.2147/ORR.S309995","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Trialling is a key step in total knee arthroplasty (TKA) and helps the surgeon assess for adequate balancing, range of motion, and stability. Despite this, there are no studies investigating knee kinematics when using trial versus final polyethylene tibial inserts.</p><p><strong>Materials and methods: </strong>Fourteen fresh frozen cadaveric specimens were cycled in a VIVO joint motion simulator. Using both simple compression and simulated muscle loads, joints were tested after TKA with a trial insert or a final tibial poly insert. Anterior/posterior (AP), internal/external (IE), and varus/valgus (VV) kinematics and laxities were analyzed.</p><p><strong>Results: </strong>Knees with trial poly inserts had significantly greater AP hysteresis (difference between flexion and extension motion) than those with final poly inserts (p=0.001). There was no significant difference in IE (p=0.563) or VV (p=0.580) hysteresis. There was no difference in AP, IE, or VV motion or laxities when considering the flexion path alone. Prosthetic joints followed different paths in flexion versus extension.</p><p><strong>Conclusion: </strong>While trial tibial inserts impart valuable information, they may not accurately reproduce the same joint kinematics as final inserts. Balancing of the knee at specific degrees of flexion may depend on the path taken to get there.</p>","PeriodicalId":19608,"journal":{"name":"Orthopedic Research and Reviews","volume":"13 ","pages":"81-88"},"PeriodicalIF":1.7000,"publicationDate":"2021-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/5b/5f/orr-13-81.PMC8253892.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopedic Research and Reviews","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/ORR.S309995","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Trialling is a key step in total knee arthroplasty (TKA) and helps the surgeon assess for adequate balancing, range of motion, and stability. Despite this, there are no studies investigating knee kinematics when using trial versus final polyethylene tibial inserts.

Materials and methods: Fourteen fresh frozen cadaveric specimens were cycled in a VIVO joint motion simulator. Using both simple compression and simulated muscle loads, joints were tested after TKA with a trial insert or a final tibial poly insert. Anterior/posterior (AP), internal/external (IE), and varus/valgus (VV) kinematics and laxities were analyzed.

Results: Knees with trial poly inserts had significantly greater AP hysteresis (difference between flexion and extension motion) than those with final poly inserts (p=0.001). There was no significant difference in IE (p=0.563) or VV (p=0.580) hysteresis. There was no difference in AP, IE, or VV motion or laxities when considering the flexion path alone. Prosthetic joints followed different paths in flexion versus extension.

Conclusion: While trial tibial inserts impart valuable information, they may not accurately reproduce the same joint kinematics as final inserts. Balancing of the knee at specific degrees of flexion may depend on the path taken to get there.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在全膝关节置换术中,试用胫骨植入物可能会导致膝关节运动学与最终的Poly植入物不同。
引言:试验是全膝关节置换术(TKA)的关键步骤,有助于外科医生评估是否有足够的平衡、运动范围和稳定性。尽管如此,在使用试验与最终聚乙烯胫骨插入物时,还没有研究膝关节运动学。材料和方法:14具新鲜冷冻尸体标本在VIVO关节运动模拟器中循环。使用简单的压缩和模拟的肌肉负荷,在TKA后用试验插入物或最终的胫骨多聚插入物测试关节。分析了前/后(AP)、内/外(IE)和内翻/外翻(VV)的运动学和松弛度。结果:与最终植入poly的膝关节相比,植入试验poly的关节具有更大的AP滞后(屈曲和伸展运动之间的差异)(p=0.001)。IE(p=0.563)或VV(p=0.580)滞后没有显著差异。单独考虑屈曲路径时,AP、IE或VV运动或松弛度没有差异。人工关节在屈曲和伸展时遵循不同的路径。结论:虽然试验性胫骨插入物提供了有价值的信息,但它们可能无法准确再现与最终插入物相同的关节运动学。膝盖在特定屈曲度下的平衡可能取决于到达那里的路径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Orthopedic Research and Reviews
Orthopedic Research and Reviews Medicine-Orthopedics and Sports Medicine
CiteScore
2.80
自引率
0.00%
发文量
51
审稿时长
16 weeks
期刊介绍: Orthopedic Research and Reviews is an international, peer-reviewed, open-access journal focusing on the patho-physiology of the musculoskeletal system, trauma, surgery and other corrective interventions to restore mobility and function. Advances in new technologies, materials, techniques and pharmacological agents will be particularly welcome. Specific topics covered in the journal include: Patho-physiology and bioengineering, Technologies and materials science, Surgical techniques, including robotics, Trauma management and care, Treatment including pharmacological and non-pharmacological, Rehabilitation and Multidisciplinarian care approaches, Patient quality of life, satisfaction and preference, Health economic evaluations. The journal welcomes submitted papers covering original research, basic science and technology, clinical studies, reviews and evaluations, guidelines, expert opinion and commentary, case reports and extended reports.
期刊最新文献
Current Status of Vertebral Body Tethering for Adolescent Idiopathic Scoliosis: An Umbrella Review. Injection of Amniotic Membrane and Umbilical Cord Particulate for Muscle and Ligament Tears in Collegiate Football Athletes: A Single-Center, Retrospective Study. Exploring Musculoskeletal Injuries and Personalized Recovery Management in Athletes [Response to Letter]. Ultrasound-Guided Suprainguinal Fascia Iliaca Compartment Block in Combination with Sciatic Nerve Block for Pain Reduction in Total Hip Arthroplasty: A Prospective Randomized Controlled Study. Bilateral Stress Fractures of Amputated Tibial Stumps in the Setting of Chronic Compartment Syndrome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1