Effect of Amplifier Gain on Photoacoustic SNR (Signal to Noise Ratio) in an LED-based Photoacoustic Imaging System.

Q2 Medicine Laser therapy Pub Date : 2020-07-17 Epub Date: 2020-11-18 DOI:10.5978/islsm.20-OR-09
Toshitaka Agano, Kunio Awazu
{"title":"Effect of Amplifier Gain on Photoacoustic SNR (Signal to Noise Ratio) in an LED-based Photoacoustic Imaging System.","authors":"Toshitaka Agano, Kunio Awazu","doi":"10.5978/islsm.20-OR-09","DOIUrl":null,"url":null,"abstract":"The possibility of using photoacoustic imaging for functional diagnosis has attracted much attention especially in the clinical field. Among such imaging systems, a system, which offers real-time imaging using compact and low-priced LEDs as a light source, has appeared. Compared to solid state lasers, the LED pulse energy was extremely small, so it had been thought that imaging would be extremely difficult, but by adding a pre-amplifier, real time photoacoustic imaging became possible. However the signal-to-noise ratio (SNR) and the amplifier gain needed for making real time imaging possible have remained unclear. The present study was designed to clarify these data. The results showed that, using a tissue phantom and human fingers, an SNR > 4 and amplifier gain > 80dB were required, and demonstrated why making an image without a pre-amplifier had proved difficult.","PeriodicalId":17981,"journal":{"name":"Laser therapy","volume":"29 1","pages":"77-85"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8246327/pdf/islsm-29-77.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laser therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5978/islsm.20-OR-09","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/11/18 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

The possibility of using photoacoustic imaging for functional diagnosis has attracted much attention especially in the clinical field. Among such imaging systems, a system, which offers real-time imaging using compact and low-priced LEDs as a light source, has appeared. Compared to solid state lasers, the LED pulse energy was extremely small, so it had been thought that imaging would be extremely difficult, but by adding a pre-amplifier, real time photoacoustic imaging became possible. However the signal-to-noise ratio (SNR) and the amplifier gain needed for making real time imaging possible have remained unclear. The present study was designed to clarify these data. The results showed that, using a tissue phantom and human fingers, an SNR > 4 and amplifier gain > 80dB were required, and demonstrated why making an image without a pre-amplifier had proved difficult.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
放大器增益对基于led光声成像系统光声信噪比的影响。
利用光声成像进行功能诊断的可能性已经引起了人们的广泛关注,特别是在临床领域。在这些成像系统中,已经出现了一种使用紧凑且价格低廉的led作为光源提供实时成像的系统。与固态激光器相比,LED脉冲能量非常小,因此人们认为成像非常困难,但通过添加前置放大器,实时光声成像成为可能。然而,实现实时成像所需的信噪比(SNR)和放大器增益仍然不清楚。本研究旨在澄清这些数据。结果表明,使用组织假体和人的手指,需要信噪比> 4和放大器增益> 80dB,并证明了为什么在没有前置放大器的情况下制作图像是困难的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Laser therapy
Laser therapy Medicine-Surgery
CiteScore
2.80
自引率
0.00%
发文量
0
期刊最新文献
Evaluating the effectiveness of two wavelengths of 810 and 980 nm Diode laser with two different beam profiles on tooth discoloration in bleaching: an experimental study Low-intensity laser-assisted antimicrobial photodynamic therapy and intravascular laser irradiation of blood in oncology: systematic review and a brief report Biomechanical changes after keratorefractive lenticule extraction with CLEAR and after femtosecond LASIK, correlated with optical coherence tomography findings Frequency-doubled neodymium yttrium aluminum garnet (Nd:YAG) laser trabeculoplasty as adjuvant therapy for open-angle glaucomas Pre-prosthetic atraumatic laser-assisted mandibular rehabilitation: Er,Cr:YSGG 2780 nm for alveoloplasty and mucocele removal. A case report
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1