{"title":"Assessment of a Cationic Emulsion to Control the Tear Film Evaporation Rate.","authors":"Ali Abusharha","doi":"10.2147/OPTO.S328787","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the effect of a single application of cationic emulsion in controlling tear film evaporation and improving tear quality and quantity.</p><p><strong>Materials a methods: </strong>Twenty male subjects diagnosed with DE were enrolled in the study with an average age of 45.8 ± 6.37 years. The tear film parameters were observed at several time points post-instillation of the cationic emulsion (10, 20, 30, and 60 min). The tear evaporation rate (TER) was measured with a VapoMeter. Noninvasive tear break-up time and meniscus height were assessed using OCULUS Keratograph.</p><p><strong>Results: </strong>TER decreased by more than 20% at 20, 30, and 60 minutes time points after instillation of single drop of cationic emulsion. Also, a significant improvement in tear film stability was found at all time points following the instillation of cationic emulsion eye drops. The mean tear break-up time increased from 5.55 ± 2.87 to 6.6 ± 4.2 sec at 60 minutes. The maximum increase in tear break-up time occurred at 30 minutes time point. The TMH was also significantly higher post-instillation of oil emulsion eye drops. There was a significant increase in the TMH post-therapy with oil drop at all time points.</p><p><strong>Conclusion: </strong>The overall study findings of this study illustrate that the single application of a cationic emulsion effectively controls tear film evaporation in patients with mild to moderate DEs. The cationic emulsion efficiently enhanced both the tear film stability and the tear meniscus volume.</p>","PeriodicalId":43701,"journal":{"name":"Clinical Optometry","volume":"13 ","pages":"243-248"},"PeriodicalIF":1.4000,"publicationDate":"2021-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/04/26/opto-13-243.PMC8364913.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Optometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTO.S328787","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To investigate the effect of a single application of cationic emulsion in controlling tear film evaporation and improving tear quality and quantity.
Materials a methods: Twenty male subjects diagnosed with DE were enrolled in the study with an average age of 45.8 ± 6.37 years. The tear film parameters were observed at several time points post-instillation of the cationic emulsion (10, 20, 30, and 60 min). The tear evaporation rate (TER) was measured with a VapoMeter. Noninvasive tear break-up time and meniscus height were assessed using OCULUS Keratograph.
Results: TER decreased by more than 20% at 20, 30, and 60 minutes time points after instillation of single drop of cationic emulsion. Also, a significant improvement in tear film stability was found at all time points following the instillation of cationic emulsion eye drops. The mean tear break-up time increased from 5.55 ± 2.87 to 6.6 ± 4.2 sec at 60 minutes. The maximum increase in tear break-up time occurred at 30 minutes time point. The TMH was also significantly higher post-instillation of oil emulsion eye drops. There was a significant increase in the TMH post-therapy with oil drop at all time points.
Conclusion: The overall study findings of this study illustrate that the single application of a cationic emulsion effectively controls tear film evaporation in patients with mild to moderate DEs. The cationic emulsion efficiently enhanced both the tear film stability and the tear meniscus volume.
期刊介绍:
Clinical Optometry is an international, peer-reviewed, open access journal focusing on clinical optometry. All aspects of patient care are addressed within the journal as well as the practice of optometry including economic and business analyses. Basic and clinical research papers are published that cover all aspects of optics, refraction and its application to the theory and practice of optometry. Specific topics covered in the journal include: Theoretical and applied optics, Delivery of patient care in optometry practice, Refraction and correction of errors, Screening and preventative aspects of eye disease, Extended clinical roles for optometrists including shared care and provision of medications, Teaching and training optometrists, International aspects of optometry, Business practice, Patient adherence, quality of life, satisfaction, Health economic evaluations.