Usability, functionality, and efficacy of a custom myoelectric elbow-wrist-hand orthosis to assist elbow function in individuals with stroke.

IF 2 Q3 ENGINEERING, BIOMEDICAL Journal of Rehabilitation and Assistive Technologies Engineering Pub Date : 2021-08-27 eCollection Date: 2021-01-01 DOI:10.1177/20556683211035057
Shenan Hoppe-Ludwig, Jodi Armitage, Kristi L Turner, Megan K O'Brien, Chaithanya K Mummidisetty, Lori McGee Koch, Masha Kocherginsky, Arun Jayaraman
{"title":"Usability, functionality, and efficacy of a custom myoelectric elbow-wrist-hand orthosis to assist elbow function in individuals with stroke.","authors":"Shenan Hoppe-Ludwig,&nbsp;Jodi Armitage,&nbsp;Kristi L Turner,&nbsp;Megan K O'Brien,&nbsp;Chaithanya K Mummidisetty,&nbsp;Lori McGee Koch,&nbsp;Masha Kocherginsky,&nbsp;Arun Jayaraman","doi":"10.1177/20556683211035057","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>After stroke, upper limb impairment affects independent performance of activities of daily living. We evaluated the usability, functionality, and efficacy of a myoelectric elbow-wrist-hand orthosis to provide support, limit unsafe motion, and enhance the functional motion of paralyzed or weak upper limbs.</p><p><strong>Methods: </strong>Individuals with stroke participated in a single-session study to evaluate the device. Ability to activate the device was tested in supported and unsupported shoulder position, as well as the elbow range of motion, ability to maintain elbow position, and ability to lift and hold a range of weights while using the device.</p><p><strong>Results: </strong>No adverse events were reported. 71% of users were able to operate the device in all three active myoelectric activation modes (Biceps, Triceps, Dual) during testing. Users were able to hold a range of wrist weights (0.5-2 lbs) for 10-120 seconds, with the largest percentage of participants able to hold weights with the device in Biceps Mode.</p><p><strong>Conclusions: </strong>The myoelectric elbow-wrist-hand orthosis improved range of motion during use and was efficacious at remediating upper extremity impairment after stroke. All users could operate the device in at least one mode, and most could lift and hold weights representative of some everyday objects using the device.</p>","PeriodicalId":43319,"journal":{"name":"Journal of Rehabilitation and Assistive Technologies Engineering","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2021-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/97/80/10.1177_20556683211035057.PMC8404626.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rehabilitation and Assistive Technologies Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/20556683211035057","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 1

Abstract

Introduction: After stroke, upper limb impairment affects independent performance of activities of daily living. We evaluated the usability, functionality, and efficacy of a myoelectric elbow-wrist-hand orthosis to provide support, limit unsafe motion, and enhance the functional motion of paralyzed or weak upper limbs.

Methods: Individuals with stroke participated in a single-session study to evaluate the device. Ability to activate the device was tested in supported and unsupported shoulder position, as well as the elbow range of motion, ability to maintain elbow position, and ability to lift and hold a range of weights while using the device.

Results: No adverse events were reported. 71% of users were able to operate the device in all three active myoelectric activation modes (Biceps, Triceps, Dual) during testing. Users were able to hold a range of wrist weights (0.5-2 lbs) for 10-120 seconds, with the largest percentage of participants able to hold weights with the device in Biceps Mode.

Conclusions: The myoelectric elbow-wrist-hand orthosis improved range of motion during use and was efficacious at remediating upper extremity impairment after stroke. All users could operate the device in at least one mode, and most could lift and hold weights representative of some everyday objects using the device.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
自定义肌电肘-腕-手矫形器辅助中风患者肘功能的可用性、功能和功效
中风后,上肢损伤会影响日常生活活动的独立表现。我们评估了肌电肘腕手矫形器的可用性、功能和有效性,以提供支持,限制不安全的运动,并增强瘫痪或虚弱上肢的功能性运动。方法:脑卒中患者参加一项单期研究来评估该装置。测试了在有支撑和无支撑的肩部位置激活设备的能力,以及肘部的运动范围,保持肘部位置的能力,以及在使用设备时举起和握住一系列重物的能力。结果:无不良事件报告。在测试期间,71%的用户能够在所有三种活动肌电激活模式(肱二头肌、肱三头肌、双肌)下操作该设备。用户能够保持手腕重量(0.5-2磅)10-120秒,在肱二头肌模式下能够保持重量的参与者比例最大。结论:肌电肘腕手矫形器改善了使用时的活动范围,对脑卒中后上肢损伤的修复是有效的。所有用户都可以在至少一种模式下操作该设备,大多数用户都可以使用该设备举起和握住代表一些日常物品的重物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
5.00%
发文量
37
期刊最新文献
Artificial intelligence approach for detecting and classifying abnormal behaviour in older adults using wearable sensors. Designing feelings into lower-limb prostheses - A kansei engineering approach to understand lower-limb prosthetic cosmeses. Public opinion on types of voice systems for older adults. Initial feasibility evaluation of the RISES system: An innovative and activity-based closed-loop framework for spinal cord injury rehabilitation and recovery. Inclusive rehabilitation and assistive technologies development: An exploration of considerations, principles, and stakeholder engagement.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1