Tomographic Analysis of Positioning of Reverse Baseplates Positioning.

Journal of shoulder and elbow arthroplasty Pub Date : 2021-02-15 eCollection Date: 2021-01-01 DOI:10.1177/2471549220987714
Alexandre Almeida, Daniel C Agostini, Pietro Ft Nesello, Nayvaldo C de Almeida, Rafael Mioso, Ana Paula Agostini
{"title":"Tomographic Analysis of Positioning of Reverse Baseplates Positioning.","authors":"Alexandre Almeida,&nbsp;Daniel C Agostini,&nbsp;Pietro Ft Nesello,&nbsp;Nayvaldo C de Almeida,&nbsp;Rafael Mioso,&nbsp;Ana Paula Agostini","doi":"10.1177/2471549220987714","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To verify whether reverse baseplate positioning without the support of intraoperative three-dimensional technology is within the acceptable parameters in the literature and whether glenoid bone deformity (GBD) compromises this positioning.</p><p><strong>Methods: </strong>Sixty-nine reverse shoulder arthroplasties were evaluated with volumetric computed tomography (CT). Two radiologists performed blinded CT scan analysis and evaluated baseplate position within 2mm of the inferior glenoid; the inclination and version of the baseplate in relation to the Friedman line; and upper and lower screw and baseplate metallic peg end point positionings. The patients were divided according to the presence of GBD for statistical analyses.</p><p><strong>Results: </strong>The two radiologists concurred reasonably in their interpretations of the following analyzed parameters: baseplate position within 2mm of the inferior glenoid rim (97.1% and 95.7%), baseplate inclination (82.6% and 81.2%), baseplate version (69.6% and 56.5%), the upper screw reaching the base of the coracoid process (71% and 79.7%), the inferior screw remaining inside the scapula (88.4% and 84.1%), and the metallic peg of the baseplate considered intraosseous (88.4% and 72.5%).</p><p><strong>Conclusion: </strong>Reverse baseplate positioning without intraoperative three-dimensional technology is within the acceptable parameters of the literature, except for baseplate version and upper screw position. GBD did not interfere with baseplate positioning in reverse shoulder arthroplasty.</p>","PeriodicalId":73942,"journal":{"name":"Journal of shoulder and elbow arthroplasty","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/2471549220987714","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of shoulder and elbow arthroplasty","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/2471549220987714","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Objective: To verify whether reverse baseplate positioning without the support of intraoperative three-dimensional technology is within the acceptable parameters in the literature and whether glenoid bone deformity (GBD) compromises this positioning.

Methods: Sixty-nine reverse shoulder arthroplasties were evaluated with volumetric computed tomography (CT). Two radiologists performed blinded CT scan analysis and evaluated baseplate position within 2mm of the inferior glenoid; the inclination and version of the baseplate in relation to the Friedman line; and upper and lower screw and baseplate metallic peg end point positionings. The patients were divided according to the presence of GBD for statistical analyses.

Results: The two radiologists concurred reasonably in their interpretations of the following analyzed parameters: baseplate position within 2mm of the inferior glenoid rim (97.1% and 95.7%), baseplate inclination (82.6% and 81.2%), baseplate version (69.6% and 56.5%), the upper screw reaching the base of the coracoid process (71% and 79.7%), the inferior screw remaining inside the scapula (88.4% and 84.1%), and the metallic peg of the baseplate considered intraosseous (88.4% and 72.5%).

Conclusion: Reverse baseplate positioning without intraoperative three-dimensional technology is within the acceptable parameters of the literature, except for baseplate version and upper screw position. GBD did not interfere with baseplate positioning in reverse shoulder arthroplasty.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
反底板定位的层析成像分析。
目的:验证无术中三维技术支持的反向底板定位是否在文献可接受的参数范围内,以及关节盂骨畸形(GBD)是否影响这种定位。方法:对69例肩关节置换术患者进行体积计算机断层扫描(CT)评价。两名放射科医生进行盲法CT扫描分析并评估下关节盂2mm内的底板位置;底板相对于弗里德曼线的倾斜度和版本;以及上下螺丝与底板金属钉的端点定位。根据是否存在GBD进行分组,进行统计学分析。结果:两名放射科医师对以下分析参数的解释一致,其中:底板位置距下盂缘2mm以内(97.1%和95.7%)、底板倾角(82.6%和81.2%)、底板版本(69.6%和56.5%)、上螺钉到达喙突基部(71%和79.7%)、下螺钉留在肩胛骨内(88.4%和84.1%)、底板金属钉认为是骨内(88.4%和72.5%)。结论:除基板版本和上钉位置外,术中无三维技术的反向基板定位均在文献可接受的参数范围内。在反向肩关节置换术中,GBD不影响底板定位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
10 weeks
期刊最新文献
Locked Stem Reverse Total Shoulder Arthroplasty for Complex Proximal Humerus Fracture in the Elderly: Clinical and Radiological Short-Term Results. Corticosteroid Infiltration to Treat Shoulder Stiffness After Rotator Cuff Repair. Modified Weaver Dunn Versus Ligamentous Reconstruction Grafts in Chronic Acromioclavicular Joint Dislocation: A Systematic Review and Meta-Analysis of Comparative Studies. Short-Term Radiographic Outcomes of Bone Versus Metallic Augmented, Central Screw Type Baseplate in Reverse Total Shoulder Arthroplasty: Matched Case-Control Study. Distal Clavicular Resection Worsens Outcomes in Rotator Cuff Repair: A National Database Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1