A One-pot-synthesized Double-layered Anticoagulant Hydrogel Tube.

IF 3.1 4区 化学 Q2 CHEMISTRY, MULTIDISCIPLINARY Chemical Research in Chinese Universities Pub Date : 2021-01-01 Epub Date: 2021-09-04 DOI:10.1007/s40242-021-1267-3
Di Sun, Wenqing Gao, Peng Wu, Jie Liu, Shengmei Li, Shilin Li, Meili Yu, Meng Ning, Ru Bai, Tong Li, Ying Liu, Chunying Chen
{"title":"A One-pot-synthesized Double-layered Anticoagulant Hydrogel Tube.","authors":"Di Sun,&nbsp;Wenqing Gao,&nbsp;Peng Wu,&nbsp;Jie Liu,&nbsp;Shengmei Li,&nbsp;Shilin Li,&nbsp;Meili Yu,&nbsp;Meng Ning,&nbsp;Ru Bai,&nbsp;Tong Li,&nbsp;Ying Liu,&nbsp;Chunying Chen","doi":"10.1007/s40242-021-1267-3","DOIUrl":null,"url":null,"abstract":"<p><p><b>E</b>xtracorporeal membrane oxygenation(ECMO) has emerged as a viable treatment in severe cases of acute respiratory distress syndrome, acute respiratory failure, and adult respiratory distress syndrome. However, thromboembolic events stemming from the use of ECMO devices results in significant morbidity and mortality rates; the inner surface of the ECMO tubing comes into contact with the blood and can readily initiate coagulation. In addition, the tubing needs to be continually replaced due to thromboses on the inner tube wall, which not only increases the risk of infection but also the economic burden. Despite considerable effort, a surface modification strategy that effectively addresses these challenges has not yet been realized. In this study, we developed an integrated hollow core-shell-shell hydrogel tube of gelatin/alginate/acrylamide-bacterial nanocellulose(GAA) that meets the anticoagulant requirements for the inner tubing layer as well as the highly elastic soft material needed for the outer layer. Using static blood from healthy volunteers, we confirmed that the platelets or coagulation is not stimulated by the GAA tubing. Importantly, experiments with dynamic blood also demonstrated that the inner layer of the tubing does not elicit blood clotting. The one-pot-synthesized process may provide guidance for the design of anticoagulation tubes used clinically.</p><p><strong>Electronic supplementary material: </strong>Supplementary material is available in the online version of this article at 10.1007/s40242-021-1267-3.</p>","PeriodicalId":9785,"journal":{"name":"Chemical Research in Chinese Universities","volume":"37 5","pages":"1085-1091"},"PeriodicalIF":3.1000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8418287/pdf/","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical Research in Chinese Universities","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s40242-021-1267-3","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/9/4 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 4

Abstract

Extracorporeal membrane oxygenation(ECMO) has emerged as a viable treatment in severe cases of acute respiratory distress syndrome, acute respiratory failure, and adult respiratory distress syndrome. However, thromboembolic events stemming from the use of ECMO devices results in significant morbidity and mortality rates; the inner surface of the ECMO tubing comes into contact with the blood and can readily initiate coagulation. In addition, the tubing needs to be continually replaced due to thromboses on the inner tube wall, which not only increases the risk of infection but also the economic burden. Despite considerable effort, a surface modification strategy that effectively addresses these challenges has not yet been realized. In this study, we developed an integrated hollow core-shell-shell hydrogel tube of gelatin/alginate/acrylamide-bacterial nanocellulose(GAA) that meets the anticoagulant requirements for the inner tubing layer as well as the highly elastic soft material needed for the outer layer. Using static blood from healthy volunteers, we confirmed that the platelets or coagulation is not stimulated by the GAA tubing. Importantly, experiments with dynamic blood also demonstrated that the inner layer of the tubing does not elicit blood clotting. The one-pot-synthesized process may provide guidance for the design of anticoagulation tubes used clinically.

Electronic supplementary material: Supplementary material is available in the online version of this article at 10.1007/s40242-021-1267-3.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一罐合成双层抗凝水凝胶管。
体外膜氧合(ECMO)已成为急性呼吸窘迫综合征,急性呼吸衰竭和成人呼吸窘迫综合征重症病例的可行治疗方法。然而,使用ECMO装置引起的血栓栓塞事件导致显著的发病率和死亡率;ECMO管的内表面与血液接触,很容易引发凝血。此外,由于内壁有血栓形成,需要不断更换导管,这不仅增加了感染的风险,而且增加了经济负担。尽管付出了巨大的努力,但有效解决这些挑战的表面改性策略尚未实现。在本研究中,我们开发了一种由明胶/海藻酸盐/丙烯酰胺-细菌纳米纤维素(GAA)组成的一体化中空核-壳-壳水凝胶管,既满足内层的抗凝要求,又满足外层所需的高弹性软质材料。使用健康志愿者的静态血液,我们确认GAA管不会刺激血小板或凝血。重要的是,动态血液实验也表明,管内层不会引起血液凝固。该工艺可为临床使用的抗凝管设计提供指导。电子补充资料:本文的在线版本为10.1007/s40242-021-1267-3。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.30
自引率
6.50%
发文量
152
审稿时长
3.0 months
期刊介绍: The journal publishes research articles, letters/communications and reviews written by faculty members, researchers and postgraduates in universities, colleges and research institutes all over China and overseas. It reports the latest and most creative results of important fundamental research in all aspects of chemistry and of developments with significant consequences across subdisciplines. Main research areas include (but are not limited to): Organic chemistry (synthesis, characterization, and application); Inorganic chemistry (bio-inorganic chemistry, inorganic material chemistry); Analytical chemistry (especially chemometrics and the application of instrumental analysis and spectroscopy); Physical chemistry (mechanisms, catalysis, thermodynamics and dynamics); Polymer chemistry and polymer physics (mechanisms, material, catalysis, thermodynamics and dynamics); Quantum chemistry (quantum mechanical theory, quantum partition function, quantum statistical mechanics); Biochemistry; Biochemical engineering; Medicinal chemistry; Nanoscience (nanochemistry, nanomaterials).
期刊最新文献
Zeolite-confined Fe-site Catalysts for the Hydrogenation of CO2 to Produce High-value Chemicals Fatigue-resistant Hydrogels Discovery of Novel Anthranilic Diamide Derivatives Bearing Sulfoximine Group as Potent Insecticide Candidates Strategy for Detecting Systemic Treatment Sensitivity of Primary Liver Cancer Based on a Novel Infrared-emissive Organic Nanoparticle Engineering the Interface Between Au Nanoparticles and CoO-Ov to Enhance the Catalytic Performance of 5-Hydroxymethylfurfural (HMF) to 2,5-Dimethylfuran (DMF)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1