Sensitivity and Specificity of New Visual Field Screening Software for Diagnosing Hemianopia.

IF 3.1 Q1 OPHTHALMOLOGY Eye and Brain Pub Date : 2021-08-29 eCollection Date: 2021-01-01 DOI:10.2147/EB.S315403
Supharat Jariyakosol, Patcharaporn Jaru-Ampornpan, Anita Manassakorn, Rath Itthipanichpong, Parima Hirunwiwatkul, Visanee Tantisevi, Thanapong Somkijrungroj, Prin Rojanapongpun
{"title":"Sensitivity and Specificity of New Visual Field Screening Software for Diagnosing Hemianopia.","authors":"Supharat Jariyakosol,&nbsp;Patcharaporn Jaru-Ampornpan,&nbsp;Anita Manassakorn,&nbsp;Rath Itthipanichpong,&nbsp;Parima Hirunwiwatkul,&nbsp;Visanee Tantisevi,&nbsp;Thanapong Somkijrungroj,&nbsp;Prin Rojanapongpun","doi":"10.2147/EB.S315403","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the diagnostic accuracy of visual field results generated by the newly developed software (CU-VF) and the standard automated perimetry (SAP) for detecting hemianopia.</p><p><strong>Patients and methods: </strong>Forty-three subjects with hemianopia and 33 controls were tested with the CU-VF software on a personal computer and SAP. Hemianopia was defined as the presence of a hemianopic field respecting the vertical meridian on SAP with the corresponding neuroimaging pathology as evaluated by 2 neuro-ophthalmologists. Results of CU-VF were independently evaluated by 2 neuro-ophthalmologists, 1 general ophthalmologist, and 1 general practitioner in terms of the presence of hemianopia. Sensitivity, specificity, and kappa coefficient for inter-observer reliability were calculated. Satisfaction and ease of use were evaluated with a visual analog-scale questionnaire and analyzed using paired <i>t</i>-test.</p><p><strong>Results: </strong>The sensitivity (95% CI) and specificity (95% CI) of the CU-VF to detect hemianopia was 74.42% (58.53-85.96) and 93.94% (78.38-99.94). Kappa coefficient between neuro-ophthalmologists versus general ophthalmologist and general practitioner were 0.71 and 0.84, respectively. The mean (SD) test duration was 2.25 (0.002) minutes for the CU-VF and 5.38 (1.34) minutes for SAP (p < 0.001). Subjects reported significantly higher satisfaction and comfort using the CU-VF software compared to SAP.</p><p><strong>Conclusion: </strong>The CU-VF screening software showed good validity and reliability to detect hemianopia, with shorter test duration and higher subject satisfaction compared to SAP.</p>","PeriodicalId":51844,"journal":{"name":"Eye and Brain","volume":"13 ","pages":"231-238"},"PeriodicalIF":3.1000,"publicationDate":"2021-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/99/a8/eb-13-231.PMC8412821.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye and Brain","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/EB.S315403","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: To assess the diagnostic accuracy of visual field results generated by the newly developed software (CU-VF) and the standard automated perimetry (SAP) for detecting hemianopia.

Patients and methods: Forty-three subjects with hemianopia and 33 controls were tested with the CU-VF software on a personal computer and SAP. Hemianopia was defined as the presence of a hemianopic field respecting the vertical meridian on SAP with the corresponding neuroimaging pathology as evaluated by 2 neuro-ophthalmologists. Results of CU-VF were independently evaluated by 2 neuro-ophthalmologists, 1 general ophthalmologist, and 1 general practitioner in terms of the presence of hemianopia. Sensitivity, specificity, and kappa coefficient for inter-observer reliability were calculated. Satisfaction and ease of use were evaluated with a visual analog-scale questionnaire and analyzed using paired t-test.

Results: The sensitivity (95% CI) and specificity (95% CI) of the CU-VF to detect hemianopia was 74.42% (58.53-85.96) and 93.94% (78.38-99.94). Kappa coefficient between neuro-ophthalmologists versus general ophthalmologist and general practitioner were 0.71 and 0.84, respectively. The mean (SD) test duration was 2.25 (0.002) minutes for the CU-VF and 5.38 (1.34) minutes for SAP (p < 0.001). Subjects reported significantly higher satisfaction and comfort using the CU-VF software compared to SAP.

Conclusion: The CU-VF screening software showed good validity and reliability to detect hemianopia, with shorter test duration and higher subject satisfaction compared to SAP.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型视野筛查软件诊断偏视的敏感性和特异性。
目的:评价新开发的软件(CU-VF)和标准自动视距仪(SAP)对偏视的诊断准确性。患者和方法:43名偏视患者和33名对照者使用个人电脑上的CU-VF软件和SAP进行测试。由2名神经眼科医生评估,在SAP上出现偏视视场并伴有相应的神经影像学病理,即为偏视。CU-VF的结果由2名神经眼科医生、1名普通眼科医生和1名全科医生独立评估是否存在偏视。计算观察者间信度的敏感性、特异性和kappa系数。使用视觉模拟量表评估满意度和易用性,并使用配对t检验进行分析。结果:CU-VF检测偏视的灵敏度(95% CI)和特异性(95% CI)分别为74.42%(58.53 ~ 85.96)和93.94%(78.38 ~ 99.94)。神经眼科医生与普通眼科医生和全科医生的Kappa系数分别为0.71和0.84。CU-VF的平均(SD)测试时间为2.25(0.002)分钟,SAP的平均(SD)测试时间为5.38(1.34)分钟(p < 0.001)。结论:与SAP相比,CU-VF筛选软件检测偏视具有较好的效度和信度,测试时间短,受试者满意度高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Eye and Brain
Eye and Brain OPHTHALMOLOGY-
CiteScore
7.90
自引率
2.30%
发文量
12
审稿时长
16 weeks
期刊介绍: Eye and Brain is an international, peer-reviewed, open access journal focusing on basic research, clinical findings, and expert reviews in the field of visual science and neuro-ophthalmology. The journal’s unique focus is the link between two well-known visual centres, the eye and the brain, with an emphasis on the importance of such connections. All aspects of clinical and especially basic research on the visual system are addressed within the journal as well as significant future directions in vision research and therapeutic measures. This unique journal focuses on neurological aspects of vision – both physiological and pathological. The scope of the journal spans from the cornea to the associational visual cortex and all the visual centers in between. Topics range from basic biological mechanisms to therapeutic treatment, from simple organisms to humans, and utilizing techniques from molecular biology to behavior. The journal especially welcomes primary research articles or review papers that make the connection between the eye and the brain. Specific areas covered in the journal include: Physiology and pathophysiology of visual centers, Eye movement disorders and strabismus, Cellular, biochemical, and molecular features of the visual system, Structural and functional organization of the eye and of the visual cortex, Metabolic demands of the visual system, Diseases and disorders with neuro-ophthalmic manifestations, Clinical and experimental neuro-ophthalmology and visual system pathologies, Epidemiological studies.
期刊最新文献
Peripapillary Retinal Nerve Fiber Layer (pRNFL) Thickness - A Novel Biomarker of Neurodegeneration in Late-Infantile CLN2 Disease. Correlations Between Disability Score, Optical Coherence Tomography and Microperimetry in Patients with Multiple Sclerosis. Impact of transcranial Direct Current Stimulation on stereoscopic vision and retinal structure in adult amblyopic rodents. Accuracy of Diagnosing Optic Neuritis Using DANTE T1-SPACE Imaging. Spotlight on Hemorrhagic Destruction of the Brain, Subependymal Calcification, and Congenital Cataracts (HDBSCC).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1