Comparison of the Thickness of the Fiber Layer of the Retinal Nerves in Spectral Domain Optical Coherence Tomography in Normal Eyes Older Than 40 Years.

IF 0.8 4区 医学 Q4 OPHTHALMOLOGY Klinische Monatsblatter fur Augenheilkunde Pub Date : 2024-07-01 Epub Date: 2021-09-15 DOI:10.1055/a-1554-5663
Medine Gündogan, Soner Kiliç
{"title":"Comparison of the Thickness of the Fiber Layer of the Retinal Nerves in Spectral Domain Optical Coherence Tomography in Normal Eyes Older Than 40 Years.","authors":"Medine Gündogan, Soner Kiliç","doi":"10.1055/a-1554-5663","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare measurements of the thickness of the retinal nerve fibre layer (RNFL) and assess the agreement between three different devices for spectral domain optical coherence tomography.</p><p><strong>Material and methods: </strong>The RNFL thickness of both eyes of 23 normal subjects older than 40 years was measured using Canon HS100, Topcon Maestro, and NIDEK RS-3000 devices. Both eyes of each subject were scanned in random order. All scans were completed on the same day in the morning. The average and four quadrants (superior, inferior, nasal, and temporal) of RNFL thickness were measured. To determine the differences in RNFL thickness, analysis of variance for repeated measurements was performed. A Bland-Altman plot was plotted, and coefficients of determination were calculated.</p><p><strong>Results: </strong>A total of 46 eyes of 23 subjects were enrolled in this study. The average RNFL thickness as determined by the three OCT devices was correlated (p < 0.001), but differed significantly between the three devices, as most were quadrant measurements. The mean average RNFL thickness was 98.5 ± 6.6 µm as measured by Canon HS100, 108.5 ± 8.8 µm as measured by Topcon Maestro, and 104.9 ± 9.0 µm as measured by NIDEK RS-3000. Topcon Maestro showed the highest average RNFL thickness value. Bland-Altman plots revealed considerable agreement among the three devices, except for the inferior quadrants between Topcon Maestro and NIDEK RS-3000 measurements. All three devices reveal considerable coefficients of determination values for mean RNFL thickness (0.917 - 0.127).</p><p><strong>Conclusion: </strong>Although the peripapillary RNFL thickness measurements taken with Canon HS100, Topcon Maestro, and NIDEK RS-3000 were in good agreement, they were not interchangeable in clinical practice, as the values differed significantly.</p>","PeriodicalId":17904,"journal":{"name":"Klinische Monatsblatter fur Augenheilkunde","volume":" ","pages":"813-818"},"PeriodicalIF":0.8000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Klinische Monatsblatter fur Augenheilkunde","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-1554-5663","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/9/15 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare measurements of the thickness of the retinal nerve fibre layer (RNFL) and assess the agreement between three different devices for spectral domain optical coherence tomography.

Material and methods: The RNFL thickness of both eyes of 23 normal subjects older than 40 years was measured using Canon HS100, Topcon Maestro, and NIDEK RS-3000 devices. Both eyes of each subject were scanned in random order. All scans were completed on the same day in the morning. The average and four quadrants (superior, inferior, nasal, and temporal) of RNFL thickness were measured. To determine the differences in RNFL thickness, analysis of variance for repeated measurements was performed. A Bland-Altman plot was plotted, and coefficients of determination were calculated.

Results: A total of 46 eyes of 23 subjects were enrolled in this study. The average RNFL thickness as determined by the three OCT devices was correlated (p < 0.001), but differed significantly between the three devices, as most were quadrant measurements. The mean average RNFL thickness was 98.5 ± 6.6 µm as measured by Canon HS100, 108.5 ± 8.8 µm as measured by Topcon Maestro, and 104.9 ± 9.0 µm as measured by NIDEK RS-3000. Topcon Maestro showed the highest average RNFL thickness value. Bland-Altman plots revealed considerable agreement among the three devices, except for the inferior quadrants between Topcon Maestro and NIDEK RS-3000 measurements. All three devices reveal considerable coefficients of determination values for mean RNFL thickness (0.917 - 0.127).

Conclusion: Although the peripapillary RNFL thickness measurements taken with Canon HS100, Topcon Maestro, and NIDEK RS-3000 were in good agreement, they were not interchangeable in clinical practice, as the values differed significantly.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
光谱域光学相干断层扫描中 40 岁以上正常眼视网膜神经纤维层厚度的比较。
目的:比较视网膜神经纤维层(RNFL)厚度的测量结果,并评估光谱域光学相干断层扫描三种不同设备之间的一致性:使用佳能 HS100、Topcon Maestro 和 NIDEK RS-3000 设备测量 23 名 40 岁以上正常受试者双眼的 RNFL 厚度。每位受试者的双眼均按随机顺序扫描。所有扫描均在同一天上午完成。测量RNFL厚度的平均值和四个象限(上、下、鼻、颞)。为确定 RNFL 厚度的差异,进行了重复测量的方差分析。绘制了布兰德-阿尔特曼图,并计算了决定系数:结果:共有 23 名受试者的 46 只眼睛参与了这项研究。三种 OCT 设备测定的平均 RNFL 厚度具有相关性(P尽管佳能 HS100、Topcon Maestro 和 NIDEK RS-3000 所测得的瞳孔周围 RNFL 厚度具有很好的一致性,但在临床实践中它们并不能互换,因为它们的值相差很大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
235
审稿时长
4-8 weeks
期刊介绍: -Konzentriertes Fachwissen aus Klinik und Praxis: Die entscheidenden Ergebnisse der internationalen Forschung - für Sie auf den Punkt gebracht und kritisch kommentiert, Übersichtsarbeiten zu den maßgeblichen Themen der täglichen Praxis, Top informiert - breite klinische Berichterstattung. -CME-Punkte sammeln mit dem Refresher: Effiziente, CME-zertifizierte Fortbildung, mit dem Refresher, 3 CME-Punkte pro Ausgabe - bis zu 36 CME-Punkte im Jahr!. -Aktuelle Rubriken mit echtem Nutzwert: Kurzreferate zu den wichtigsten Artikeln internationaler Zeitschriften, Schwerpunktthema in jedem Heft: Ausführliche Übersichtsarbeiten zu den wichtigsten Themen der Ophthalmologie – so behalten Sie das gesamte Fach im Blick!, Originalien mit den neuesten Entwicklungen, Übersichten zu den relevanten Themen.
期刊最新文献
Corneal stress distribution under Goldmann applanation tonometry procedure tested on a human cornea model. Cat eyes - iris capture as unusual complication after phakic posterior chamber intraocular lens implantation. Zum Vergleich verschiedener Selbsttonometriegeräte mit der Goldmann-Applanationstonometrie unter besonderer Berücksichtigung der biomechanischen Hornhauteigenschaften. Diabetic Macular Oedema - Patient Characteristics and the Reality of Treatment in a German University Hospital. Case Report: Periocular Steroid Injection Combined Vemurafenib Therapy in the Long-term Management of Orbital Involvement of Erdheim-Chester Disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1