{"title":"Clinical and radiographic results after ACL reconstruction using an adjustable-loop device","authors":"Youngji Kim , Mitsuaki Kubota , Keisuke Muramoto , Takuya Kunii , Taisuke Sato , Tetsuya Inui , Ryuichi Ohno , Muneaki Ishijima","doi":"10.1016/j.asmart.2021.07.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>The femoral cortical suspension device such as fixed loop devices (FLD) and adjustable-loop device (ALD) are used for ACLR technique in recent days. However, there was few studies of clinical and radiographic results for ACLR using ALD. This study was conducted to clarify the clinical and radiographic results, stability and bone tunnel enlargement after ACLR using a ToggleLoc with a zip loop as ALD.</p></div><div><h3>Methods</h3><p>80 patients who had data available from the most recent follow-up at ≥2 years since ACLR were evaluated both clinical and radiographic results. They were divided into single bundle reconstruction group (SBR) and double bundle reconstruction group (DBR). Clinical scores were included subjective scores and objective scores at pre- and postoperatively 2 years. The subjective scores were the Cincinnati knee rating system, Knee injury and Osteoarthritis Outcome Score (KOOS), Lysholm score, Tegner activity score, Visual Analog Scale (VAS) and ACL-Return to Sport after Injury (RSI) scale. The objective scores were the isokinetic muscle strength, side-to-side difference in anterior instability and single hop test. In radiographical assessment, femoral and tibial tunnel enlargement was evaluated by three-dimensional computed tomography.</p></div><div><h3>Results</h3><p>In both SBR and DBR group, the postoperative subjective scores were significantly improved compared to the preoperative values, except for the Tegner activity score. Similarly, the side-to-side differences in muscle strength, anterior instability and single hop test were significantly improved after surgery. The changes in the femoral and tibial tunnel maximum cross section areas of SBR were 104.3 % ± 21.2 % and 89.2 % ± 15.2 %, respectively, at 2 years post-operatively. In DBR, in the femoral bone volume change of the antero medial (AM) and postero lateral (PL) bundle were 107.0 ± 3.5 % and 108.1 ± 3.3, and in the tibial bone volume change of AM and PL bundle were 90.6 ± 3.3 % and 87.0 ± 4.2 %. At the femoral site, the rate of tunnel enlargement increased for the first 12 months and then decreased through 24 months postoperatively. At the tibial site, by contrast, the rate of tunnel enlargement decreased consistently over the two-year postoperative follow-up.</p></div><div><h3>Conclusion</h3><p>This is the first study to include clinical data on ACLR using a ToggleLoc with a zip loop device. ACLR using these devices as ALDs resulted in good clinical outcomes and provided good stability of the knee with relatively little bone tunnel enlargement in both SBR and DBR group.</p></div>","PeriodicalId":44283,"journal":{"name":"Asia-Pacific Journal of Sport Medicine Arthroscopy Rehabilitation and Technology","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.asmart.2021.07.002","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia-Pacific Journal of Sport Medicine Arthroscopy Rehabilitation and Technology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214687321000182","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 4
Abstract
Background
The femoral cortical suspension device such as fixed loop devices (FLD) and adjustable-loop device (ALD) are used for ACLR technique in recent days. However, there was few studies of clinical and radiographic results for ACLR using ALD. This study was conducted to clarify the clinical and radiographic results, stability and bone tunnel enlargement after ACLR using a ToggleLoc with a zip loop as ALD.
Methods
80 patients who had data available from the most recent follow-up at ≥2 years since ACLR were evaluated both clinical and radiographic results. They were divided into single bundle reconstruction group (SBR) and double bundle reconstruction group (DBR). Clinical scores were included subjective scores and objective scores at pre- and postoperatively 2 years. The subjective scores were the Cincinnati knee rating system, Knee injury and Osteoarthritis Outcome Score (KOOS), Lysholm score, Tegner activity score, Visual Analog Scale (VAS) and ACL-Return to Sport after Injury (RSI) scale. The objective scores were the isokinetic muscle strength, side-to-side difference in anterior instability and single hop test. In radiographical assessment, femoral and tibial tunnel enlargement was evaluated by three-dimensional computed tomography.
Results
In both SBR and DBR group, the postoperative subjective scores were significantly improved compared to the preoperative values, except for the Tegner activity score. Similarly, the side-to-side differences in muscle strength, anterior instability and single hop test were significantly improved after surgery. The changes in the femoral and tibial tunnel maximum cross section areas of SBR were 104.3 % ± 21.2 % and 89.2 % ± 15.2 %, respectively, at 2 years post-operatively. In DBR, in the femoral bone volume change of the antero medial (AM) and postero lateral (PL) bundle were 107.0 ± 3.5 % and 108.1 ± 3.3, and in the tibial bone volume change of AM and PL bundle were 90.6 ± 3.3 % and 87.0 ± 4.2 %. At the femoral site, the rate of tunnel enlargement increased for the first 12 months and then decreased through 24 months postoperatively. At the tibial site, by contrast, the rate of tunnel enlargement decreased consistently over the two-year postoperative follow-up.
Conclusion
This is the first study to include clinical data on ACLR using a ToggleLoc with a zip loop device. ACLR using these devices as ALDs resulted in good clinical outcomes and provided good stability of the knee with relatively little bone tunnel enlargement in both SBR and DBR group.
期刊介绍:
The Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology (AP-SMART) is the official peer-reviewed, open access journal of the Asia-Pacific Knee, Arthroscopy and Sports Medicine Society (APKASS) and the Japanese Orthopaedic Society of Knee, Arthroscopy and Sports Medicine (JOSKAS). It is published quarterly, in January, April, July and October, by Elsevier. The mission of AP-SMART is to inspire clinicians, practitioners, scientists and engineers to work towards a common goal to improve quality of life in the international community. The Journal publishes original research, reviews, editorials, perspectives, and letters to the Editor. Multidisciplinary research with collaboration amongst clinicians and scientists from different disciplines will be the trend in the coming decades. AP-SMART provides a platform for the exchange of new clinical and scientific information in the most precise and expeditious way to achieve timely dissemination of information and cross-fertilization of ideas.