{"title":"Clinical and radiographic results after ACL reconstruction using an adjustable-loop device","authors":"Youngji Kim ,&nbsp;Mitsuaki Kubota ,&nbsp;Keisuke Muramoto ,&nbsp;Takuya Kunii ,&nbsp;Taisuke Sato ,&nbsp;Tetsuya Inui ,&nbsp;Ryuichi Ohno ,&nbsp;Muneaki Ishijima","doi":"10.1016/j.asmart.2021.07.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>The femoral cortical suspension device such as fixed loop devices (FLD) and adjustable-loop device (ALD) are used for ACLR technique in recent days. However, there was few studies of clinical and radiographic results for ACLR using ALD. This study was conducted to clarify the clinical and radiographic results, stability and bone tunnel enlargement after ACLR using a ToggleLoc with a zip loop as ALD.</p></div><div><h3>Methods</h3><p>80 patients who had data available from the most recent follow-up at ≥2 years since ACLR were evaluated both clinical and radiographic results. They were divided into single bundle reconstruction group (SBR) and double bundle reconstruction group (DBR). Clinical scores were included subjective scores and objective scores at pre- and postoperatively 2 years. The subjective scores were the Cincinnati knee rating system, Knee injury and Osteoarthritis Outcome Score (KOOS), Lysholm score, Tegner activity score, Visual Analog Scale (VAS) and ACL-Return to Sport after Injury (RSI) scale. The objective scores were the isokinetic muscle strength, side-to-side difference in anterior instability and single hop test. In radiographical assessment, femoral and tibial tunnel enlargement was evaluated by three-dimensional computed tomography.</p></div><div><h3>Results</h3><p>In both SBR and DBR group, the postoperative subjective scores were significantly improved compared to the preoperative values, except for the Tegner activity score. Similarly, the side-to-side differences in muscle strength, anterior instability and single hop test were significantly improved after surgery. The changes in the femoral and tibial tunnel maximum cross section areas of SBR were 104.3 % ± 21.2 % and 89.2 % ± 15.2 %, respectively, at 2 years post-operatively. In DBR, in the femoral bone volume change of the antero medial (AM) and postero lateral (PL) bundle were 107.0 ± 3.5 % and 108.1 ± 3.3, and in the tibial bone volume change of AM and PL bundle were 90.6 ± 3.3 % and 87.0 ± 4.2 %. At the femoral site, the rate of tunnel enlargement increased for the first 12 months and then decreased through 24 months postoperatively. At the tibial site, by contrast, the rate of tunnel enlargement decreased consistently over the two-year postoperative follow-up.</p></div><div><h3>Conclusion</h3><p>This is the first study to include clinical data on ACLR using a ToggleLoc with a zip loop device. ACLR using these devices as ALDs resulted in good clinical outcomes and provided good stability of the knee with relatively little bone tunnel enlargement in both SBR and DBR group.</p></div>","PeriodicalId":44283,"journal":{"name":"Asia-Pacific Journal of Sport Medicine Arthroscopy Rehabilitation and Technology","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.asmart.2021.07.002","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia-Pacific Journal of Sport Medicine Arthroscopy Rehabilitation and Technology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214687321000182","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 4

Abstract

Background

The femoral cortical suspension device such as fixed loop devices (FLD) and adjustable-loop device (ALD) are used for ACLR technique in recent days. However, there was few studies of clinical and radiographic results for ACLR using ALD. This study was conducted to clarify the clinical and radiographic results, stability and bone tunnel enlargement after ACLR using a ToggleLoc with a zip loop as ALD.

Methods

80 patients who had data available from the most recent follow-up at ≥2 years since ACLR were evaluated both clinical and radiographic results. They were divided into single bundle reconstruction group (SBR) and double bundle reconstruction group (DBR). Clinical scores were included subjective scores and objective scores at pre- and postoperatively 2 years. The subjective scores were the Cincinnati knee rating system, Knee injury and Osteoarthritis Outcome Score (KOOS), Lysholm score, Tegner activity score, Visual Analog Scale (VAS) and ACL-Return to Sport after Injury (RSI) scale. The objective scores were the isokinetic muscle strength, side-to-side difference in anterior instability and single hop test. In radiographical assessment, femoral and tibial tunnel enlargement was evaluated by three-dimensional computed tomography.

Results

In both SBR and DBR group, the postoperative subjective scores were significantly improved compared to the preoperative values, except for the Tegner activity score. Similarly, the side-to-side differences in muscle strength, anterior instability and single hop test were significantly improved after surgery. The changes in the femoral and tibial tunnel maximum cross section areas of SBR were 104.3 % ± 21.2 % and 89.2 % ± 15.2 %, respectively, at 2 years post-operatively. In DBR, in the femoral bone volume change of the antero medial (AM) and postero lateral (PL) bundle were 107.0 ± 3.5 % and 108.1 ± 3.3, and in the tibial bone volume change of AM and PL bundle were 90.6 ± 3.3 % and 87.0 ± 4.2 %. At the femoral site, the rate of tunnel enlargement increased for the first 12 months and then decreased through 24 months postoperatively. At the tibial site, by contrast, the rate of tunnel enlargement decreased consistently over the two-year postoperative follow-up.

Conclusion

This is the first study to include clinical data on ACLR using a ToggleLoc with a zip loop device. ACLR using these devices as ALDs resulted in good clinical outcomes and provided good stability of the knee with relatively little bone tunnel enlargement in both SBR and DBR group.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用可调环装置重建前交叉韧带的临床和影像学结果
近年来,股骨皮质悬吊装置如固定环装置(FLD)和可调环装置(ALD)被用于ACLR技术。然而,关于ALD治疗ACLR的临床和影像学结果的研究很少。本研究旨在阐明ACLR后使用带拉链环的ToggleLoc作为ALD的临床和影像学结果、稳定性和骨隧道扩大情况。方法对80例ACLR术后≥2年的最新随访患者进行临床和影像学结果评估。分为单束重建组(SBR)和双束重建组(DBR)。临床评分包括术前和术后2年的主观评分和客观评分。主观评分为辛辛那提膝关节评分系统、膝关节损伤和骨关节炎结局评分(oos)、Lysholm评分、Tegner活动评分、视觉模拟量表(VAS)和伤后恢复运动量表(RSI)。客观评分为等速肌力、前路不稳定性侧对侧差异和单跳测试。在放射学评估中,通过三维计算机断层扫描评估股骨和胫骨隧道的扩大。结果SBR组和DBR组除Tegner活动评分外,术后主观评分均较术前有显著提高。同样,手术后肌肉力量、前路不稳定性和单跳试验的侧对侧差异也明显改善。术后2年,SBR股骨和胫骨隧道最大横截面积的变化分别为104.3%±21.2%和89.2%±15.2%。在DBR中,股骨前内侧束(AM)和后外侧束(PL)的体积变化分别为107.0±3.5%和108.1±3.3%,胫骨AM和PL束的体积变化分别为90.6±3.3%和87.0±4.2%。在股骨部位,前12个月隧道扩大率增加,术后24个月隧道扩大率下降。相比之下,在胫骨部位,隧道扩张率在两年的术后随访中持续下降。结论:这是第一个包括使用togglloc与拉链环装置ACLR临床数据的研究。在SBR和DBR组中,使用这些装置作为ald的ACLR获得了良好的临床结果,并提供了良好的膝关节稳定性和相对较小的骨隧道扩大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.80
自引率
0.00%
发文量
21
审稿时长
98 days
期刊介绍: The Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology (AP-SMART) is the official peer-reviewed, open access journal of the Asia-Pacific Knee, Arthroscopy and Sports Medicine Society (APKASS) and the Japanese Orthopaedic Society of Knee, Arthroscopy and Sports Medicine (JOSKAS). It is published quarterly, in January, April, July and October, by Elsevier. The mission of AP-SMART is to inspire clinicians, practitioners, scientists and engineers to work towards a common goal to improve quality of life in the international community. The Journal publishes original research, reviews, editorials, perspectives, and letters to the Editor. Multidisciplinary research with collaboration amongst clinicians and scientists from different disciplines will be the trend in the coming decades. AP-SMART provides a platform for the exchange of new clinical and scientific information in the most precise and expeditious way to achieve timely dissemination of information and cross-fertilization of ideas.
期刊最新文献
Factors affecting the therapeutic effects of multiple intra-articular injections of platelet-rich-plasma for knee osteoarthritis Early intervention of extracorporeal shockwave therapy sustained positive long-term effect on rotator cuff healing: A randomized controlled trial with 3-year follow-up The residual laxity of medial collateral ligament after magic point pie crusting MCL released in arthroscopic management of medial meniscus Fast rehabilitation does not worsen clinical, radiological, and arthroscopic outcomes after medial meniscus posterior root repair: A retrospective comparative study ACL injury characteristics in badminton : A registry study with prospectively collected data on sports related epidemiology and injury mechanism of 539 badminton players
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1