CaRotid Artery Filtering Technique (CRAFT): A Technique for Carotid Artery Stenting with Intrinsic Embolic Protection.

IF 1.2 Q4 CLINICAL NEUROLOGY Neurointervention Pub Date : 2021-11-01 Epub Date: 2021-10-25 DOI:10.5469/neuroint.2021.00353
Michelle Foo, Yifan Ren, Jay Gajera, Christen D Barras, Hong Kuan Kok, Ashu Jhamb, Hussein Abbouchie, Julian Maingard, Duncan Mark Brooks, Hamed Asadi
{"title":"CaRotid Artery Filtering Technique (CRAFT): A Technique for Carotid Artery Stenting with Intrinsic Embolic Protection.","authors":"Michelle Foo,&nbsp;Yifan Ren,&nbsp;Jay Gajera,&nbsp;Christen D Barras,&nbsp;Hong Kuan Kok,&nbsp;Ashu Jhamb,&nbsp;Hussein Abbouchie,&nbsp;Julian Maingard,&nbsp;Duncan Mark Brooks,&nbsp;Hamed Asadi","doi":"10.5469/neuroint.2021.00353","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Carotid artery stenting (CAS) is an established treatment for symptomatic carotid artery stenosis as an alternative to carotid endarterectomy. A variety of techniques and devices have been devised to minimise periprocedural stroke risk using either proximal or distal embolic protection. This study presents a method of embolic protection during CAS-the CaRotid Artery Filtering Technique (CRAFT).</p><p><strong>Materials and methods: </strong>The CRAFT technique employs aspects of both proximal and distal embolic protection. The CASPER RX stent (MicroVention, Tustin, CA, USA), which is a double-layered, closed-cell, micromesh nitinol stent, is deployed across the carotid artery stenosis with the assistance of a FlowGate balloon guide catheter (Stryker Neurovascular, Fremont, CA, USA). The partially deployed stent acts as a distal filter while the balloon guide is deflated midway during stent deployment to prevent distal plaque embolisation, followed by completion of stent deployment and angioplasty.</p><p><strong>Results: </strong>A total of 94 patients underwent CAS using the CRAFT technique between June 2016 and March 2021. Successful stent deployment was achieved in all patients. Preliminary results demonstrated acute stent occlusion in 6 patients (6.4%) and distal embolic stroke in 5 patients (5.3%). The median procedural fluoroscopy time was 34 minutes with an interquartile range of 22 to 55 minutes.</p><p><strong>Conclusion: </strong>The CRAFT technique of CAS presented by this study can be applied in the treatment of symptomatic carotid artery stenosis in both emergency and elective procedure settings with a high technical success and low distal embolic stroke risk.</p>","PeriodicalId":19140,"journal":{"name":"Neurointervention","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/58/59/neuroint-2021-00353.PMC8561041.pdf","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurointervention","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5469/neuroint.2021.00353","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/10/25 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 3

Abstract

Purpose: Carotid artery stenting (CAS) is an established treatment for symptomatic carotid artery stenosis as an alternative to carotid endarterectomy. A variety of techniques and devices have been devised to minimise periprocedural stroke risk using either proximal or distal embolic protection. This study presents a method of embolic protection during CAS-the CaRotid Artery Filtering Technique (CRAFT).

Materials and methods: The CRAFT technique employs aspects of both proximal and distal embolic protection. The CASPER RX stent (MicroVention, Tustin, CA, USA), which is a double-layered, closed-cell, micromesh nitinol stent, is deployed across the carotid artery stenosis with the assistance of a FlowGate balloon guide catheter (Stryker Neurovascular, Fremont, CA, USA). The partially deployed stent acts as a distal filter while the balloon guide is deflated midway during stent deployment to prevent distal plaque embolisation, followed by completion of stent deployment and angioplasty.

Results: A total of 94 patients underwent CAS using the CRAFT technique between June 2016 and March 2021. Successful stent deployment was achieved in all patients. Preliminary results demonstrated acute stent occlusion in 6 patients (6.4%) and distal embolic stroke in 5 patients (5.3%). The median procedural fluoroscopy time was 34 minutes with an interquartile range of 22 to 55 minutes.

Conclusion: The CRAFT technique of CAS presented by this study can be applied in the treatment of symptomatic carotid artery stenosis in both emergency and elective procedure settings with a high technical success and low distal embolic stroke risk.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
颈动脉过滤技术(CRAFT):一种具有内在栓塞保护的颈动脉支架植入术。
目的:颈动脉支架植入术(CAS)是一种治疗症状性颈动脉狭窄的替代方法。已经设计了各种技术和设备来使用近端或远端栓塞保护来最小化围手术期卒中风险。本研究提出了一种cas术中栓塞保护的方法——颈动脉过滤技术(CRAFT)。材料和方法:CRAFT技术采用近端和远端栓塞保护。CASPER RX支架(MicroVention, Tustin, CA, USA)是一种双层、闭细胞、微孔镍钛诺支架,在FlowGate球囊引导导管(Stryker Neurovascular, Fremont, CA, USA)的帮助下穿过颈动脉狭窄。部分部署的支架作为远端过滤器,而在支架部署期间中途放气球囊导管,以防止远端斑块栓塞,随后完成支架部署和血管成形术。结果:在2016年6月至2021年3月期间,共有94例患者使用CRAFT技术进行了CAS。所有患者均成功置放支架。初步结果显示急性支架闭塞6例(6.4%),远端栓塞性卒中5例(5.3%)。中位透视时间为34分钟,四分位数范围为22至55分钟。结论:本研究提出的CRAFT技术可应用于急诊和择期手术治疗症状性颈动脉狭窄,技术成功率高,远端栓塞性卒中风险低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
34
审稿时长
12 weeks
期刊最新文献
First-Line Aspiration Thrombectomy of M2 Occlusions with a Novel Reperfusion Catheter (REDTM 62): Real-World Experience from Two Tertiary Comprehensive Stroke Centers. Coil Embolization of a Ruptured Anterior Spinal Artery Aneurysm Associated with Spinal Cord Arteriovenous Malformation. Delayed Pontomesencephalic and Cervical Cord Venous Drainage Followed by Contralateral Carotid-Cavernous Fistula after Craniofacial Fractures: A Case Report. Endovascular Treatment of Scalp Arteriovenous Fistula: Transvenous Onyx Embolization with Balloon Occlusion. Efficacy of Endovascular Glue Embolization in Treating Ruptured Intracranial Mycotic Aneurysms: A Single Center Experience.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1