Using Smartphones for Clinical Assessment in Cervical Spondylotic Myelopathy a Feasibility Study.

IF 0.8 4区 医学 Q4 ENGINEERING, BIOMEDICAL Journal of Medical Devices-Transactions of the Asme Pub Date : 2021-12-01 Epub Date: 2021-10-22 DOI:10.1115/1.4052609
Julien Francisco Zaldivar-Jolissaint, François Lechanoine, Bernard Krummenacher, Rivus Ferreira Arruda, Lukas Bobinski, Emmanuel de Schlichting, John Michael Duff
{"title":"Using Smartphones for Clinical Assessment in Cervical Spondylotic Myelopathy a Feasibility Study.","authors":"Julien Francisco Zaldivar-Jolissaint,&nbsp;François Lechanoine,&nbsp;Bernard Krummenacher,&nbsp;Rivus Ferreira Arruda,&nbsp;Lukas Bobinski,&nbsp;Emmanuel de Schlichting,&nbsp;John Michael Duff","doi":"10.1115/1.4052609","DOIUrl":null,"url":null,"abstract":"<p><p>Degenerative cervical myelopathy (DCM) is characterized by a progressive deterioration in spinal cord function. Its evaluation requires subjective clinical examination with wide interobserver variability. Objective quantification of spinal cord function remains imprecise, even though validated myelopathy-grading scales have emerged and are now widely used. We created a Smartphone Application, the N-Outcome App, with the aim of quantifying accurately and reliably spinal cord dysfunction using a 5-minute Test. A patient suffering from DCM was clinically evaluated before surgery, at 3 and 6 months follow-up after surgical decompression of the cervical spinal cord. Standard scores (Nurick grade, modified Japanese Orthopedic Association (mJOA) score) were documented at these time points. A 5-minute motor and proprioceptive performance test aided by a smartphone with the N-outcome App was also performed. Motor performance in rapid alternating movements and finger tapping improved in correlation with improvements in standard grading scale scores. Clinical improvements were seen in maximum reflex acceleration and in Romberg testing which showed less closed/open eyes variation, suggesting pyramidal and proprioceptive function recovery. We demonstrate that using the N-Outcome App as an adjunct to clinical evaluation of compressive myelopathy is feasible and potentially useful. The results correlate with the results of clinical assessment obtained by standard validated myelopathy scores.</p>","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8822463/pdf/med-20-1212_044503.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4052609","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/10/22 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 1

Abstract

Degenerative cervical myelopathy (DCM) is characterized by a progressive deterioration in spinal cord function. Its evaluation requires subjective clinical examination with wide interobserver variability. Objective quantification of spinal cord function remains imprecise, even though validated myelopathy-grading scales have emerged and are now widely used. We created a Smartphone Application, the N-Outcome App, with the aim of quantifying accurately and reliably spinal cord dysfunction using a 5-minute Test. A patient suffering from DCM was clinically evaluated before surgery, at 3 and 6 months follow-up after surgical decompression of the cervical spinal cord. Standard scores (Nurick grade, modified Japanese Orthopedic Association (mJOA) score) were documented at these time points. A 5-minute motor and proprioceptive performance test aided by a smartphone with the N-outcome App was also performed. Motor performance in rapid alternating movements and finger tapping improved in correlation with improvements in standard grading scale scores. Clinical improvements were seen in maximum reflex acceleration and in Romberg testing which showed less closed/open eyes variation, suggesting pyramidal and proprioceptive function recovery. We demonstrate that using the N-Outcome App as an adjunct to clinical evaluation of compressive myelopathy is feasible and potentially useful. The results correlate with the results of clinical assessment obtained by standard validated myelopathy scores.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用智能手机进行脊髓型颈椎病临床评估的可行性研究。
退行性脊髓型颈椎病(DCM)以脊髓功能进行性恶化为特征。它的评价需要主观的临床检查和广泛的观察者之间的差异。脊髓功能的客观量化仍然不精确,即使有效的脊髓病分级量表已经出现,现在广泛使用。我们创建了一个智能手机应用程序,N-Outcome应用程序,目的是通过5分钟的测试准确可靠地量化脊髓功能障碍。对1例DCM患者术前、颈脊髓减压术后随访3个月和6个月进行临床评估。在这些时间点记录标准评分(Nurick评分,修改的日本骨科协会(mJOA)评分)。在带有N-outcome App的智能手机的辅助下,还进行了5分钟的运动和本体感觉性能测试。快速交替运动和手指敲击的运动表现与标准评分量表得分的提高相关。在最大反射加速和Romberg测试中观察到临床改善,闭/睁眼变化较少,表明锥体和本体感觉功能恢复。我们证明,使用N-Outcome App作为临床评估压缩性脊髓病的辅助手段是可行的,并且可能有用。结果与通过标准验证的脊髓病评分获得的临床评估结果相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.80
自引率
11.10%
发文量
56
审稿时长
6-12 weeks
期刊介绍: The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.
期刊最新文献
A Novel Design Method for the Knee Joint of the Exoskeleton Based On the Modular Wearable Sensor Experimental Investigation of the Calcified Plaque Material Removal Rate in Coronary Rotational Atherectomy Assessment of a Novel Application of the Capture-Trap-Terminate Approach for Treating Aerosol Products During Dental Procedures Development And Mechanical Testing Of Implant For Cranial Reconstruction After Burr Hole Trepanation In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1