A Comparison of the Performance between the 60- and 120-Second Conditions of the Korean-Color Word Stroop Test: Color Reading (K-CWST: CR).

Dementia and neurocognitive disorders Pub Date : 2021-10-01 Epub Date: 2021-10-21 DOI:10.12779/dnd.2021.20.4.62
Sun Hwa Lee, Yeonwook Kang, Minji Song, Geon Ha Kim, Jee Hyang Jeong
{"title":"A Comparison of the Performance between the 60- and 120-Second Conditions of the Korean-Color Word Stroop Test: Color Reading (K-CWST: CR).","authors":"Sun Hwa Lee,&nbsp;Yeonwook Kang,&nbsp;Minji Song,&nbsp;Geon Ha Kim,&nbsp;Jee Hyang Jeong","doi":"10.12779/dnd.2021.20.4.62","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>The Korean-Color Word Stroop Test: Color Reading (K-CWST: CR) included in the Seoul Neuropsychological Screening Battery, 2nd Edition (SNSB-II) examines inhibitory control deficit. It provides normative data for both 60- and 120-second conditions, but the validity of the 60-second condition has not yet been proven. This study examined the validity of the 60-second condition by observing concordance between the performances in cognitively normal, MCI, and mild dementia groups.</p><p><strong>Methods: </strong>There were 1,336 patients performed the SNSB-II, including the K-CWST: CR. Based on the cognitive test results, activities of daily living, and clinical interview, the patients were assigned to normal cognition (n=104), MCI (n=884), or mild dementia (n=348) groups. Abnormal performance on the K-CWST: CR was operationally defined as 1SD below the normative mean. The receiver operating characteristic curve analyses were conducted to compare the discriminability between the 60- and 120-second conditions.</p><p><strong>Results: </strong>The percentages of abnormal performance in the MCI group were 41.5% and 42.3%, and those in the mild dementia group were 82.7% and 82.4% for the 60- and 120-second conditions, respectively. The areas under the curve for the 60- and 120-seconds were as follows; 0.80 and 0.81 in differentiating normal from MCI; 0.95 and 0.96 in normal from mild dementia; and 0.77 and 0.77 in MCI from mild dementia.</p><p><strong>Conclusions: </strong>The 60-second condition of the K-CWST showed very similar results, not statistically different from the 120-second condition. Therefore, the 60-second condition could be used interchangeably with the 120-second condition in a clinical setting.</p>","PeriodicalId":72779,"journal":{"name":"Dementia and neurocognitive disorders","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/fb/70/dnd-20-62.PMC8585531.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dementia and neurocognitive disorders","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12779/dnd.2021.20.4.62","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/10/21 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose: The Korean-Color Word Stroop Test: Color Reading (K-CWST: CR) included in the Seoul Neuropsychological Screening Battery, 2nd Edition (SNSB-II) examines inhibitory control deficit. It provides normative data for both 60- and 120-second conditions, but the validity of the 60-second condition has not yet been proven. This study examined the validity of the 60-second condition by observing concordance between the performances in cognitively normal, MCI, and mild dementia groups.

Methods: There were 1,336 patients performed the SNSB-II, including the K-CWST: CR. Based on the cognitive test results, activities of daily living, and clinical interview, the patients were assigned to normal cognition (n=104), MCI (n=884), or mild dementia (n=348) groups. Abnormal performance on the K-CWST: CR was operationally defined as 1SD below the normative mean. The receiver operating characteristic curve analyses were conducted to compare the discriminability between the 60- and 120-second conditions.

Results: The percentages of abnormal performance in the MCI group were 41.5% and 42.3%, and those in the mild dementia group were 82.7% and 82.4% for the 60- and 120-second conditions, respectively. The areas under the curve for the 60- and 120-seconds were as follows; 0.80 and 0.81 in differentiating normal from MCI; 0.95 and 0.96 in normal from mild dementia; and 0.77 and 0.77 in MCI from mild dementia.

Conclusions: The 60-second condition of the K-CWST showed very similar results, not statistically different from the 120-second condition. Therefore, the 60-second condition could be used interchangeably with the 120-second condition in a clinical setting.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
韩文颜色词Stroop测验:颜色阅读(K-CWST: CR) 60秒和120秒条件下的表现比较
背景与目的:首尔神经心理筛查手册第二版(SNSB-II)中包含的韩文颜色单词Stroop测试:颜色阅读(K-CWST: CR)用于检测抑制控制缺陷。它提供了60秒和120秒条件的规范性数据,但60秒条件的有效性尚未得到证实。本研究通过观察认知正常组、轻度认知障碍组和轻度痴呆组的表现之间的一致性来检验60秒条件的有效性。方法:对1336例患者进行包括K-CWST: CR在内的SNSB-II测试,根据认知测试结果、日常生活活动情况和临床访谈将患者分为认知正常组(104例)、轻度认知障碍组(884例)和轻度痴呆组(348例)。在K-CWST: CR上的异常表现在操作上定义为低于规范平均值1SD。对受试者工作特征曲线进行分析,比较60秒和120秒条件下的可判别性。结果:在60秒和120秒条件下,MCI组的表现异常率分别为41.5%和42.3%,轻度痴呆组的表现异常率分别为82.7%和82.4%。60秒和120秒的曲线下面积如下:正常与轻度认知损伤的鉴别分别为0.80和0.81;从轻度痴呆到正常痴呆分别为0.95和0.96;轻度痴呆的MCI分别为0.77和0.77。结论:60秒条件下的K-CWST结果非常相似,与120秒条件下无统计学差异。因此,在临床环境中,60秒条件可以与120秒条件互换使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Comparison of Item Characteristics and Test Information Between the K-MMSE~2:SV and K-MMSE. Assessing the Impact of Defacing Algorithms on Brain Volumetry Accuracy in MRI Analyses. Discriminative Power of Seoul Cognitive Status Test in Differentiating Subjective Cognitive Decline, Amnestic Mild Cognitive Impairment, and Dementia Based on CERAD-K Standards. Shunt-Responsive Idiopathic Normal Pressure Hydrocephalus Patient With Parkinson's Disease-Compatible Findings on Dopamine Transporter Scans. Speech Emotion Recognition in People at High Risk of Dementia.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1