Microbial Contamination of Rubber Ducks Floating in Bathtubs of Bathing Facilities, and an Evaluation of Their Washing Methods.

IF 0.9 4区 农林科学 Q4 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Biocontrol science Pub Date : 2021-01-01 DOI:10.4265/bio.26.187
Akiko Edagawa, Norihiro Matsuda, Toru Ogura, Kenichi Uezono, Shinji Izumiyama, Akira Fujii
{"title":"Microbial Contamination of Rubber Ducks Floating in Bathtubs of Bathing Facilities, and an Evaluation of Their Washing Methods.","authors":"Akiko Edagawa,&nbsp;Norihiro Matsuda,&nbsp;Toru Ogura,&nbsp;Kenichi Uezono,&nbsp;Shinji Izumiyama,&nbsp;Akira Fujii","doi":"10.4265/bio.26.187","DOIUrl":null,"url":null,"abstract":"<p><p>Microbiological contamination inside rubber ducks floating in the bathtub at a \"duck bath\" of a bathing facility was analyzed by examining bacterial and amoebic counts. The results of microbial tests, such as standard plate count, heterotrophic plate count and Legionella-LAMP (Loopmediated isothermal amplification) , showed that microbial contamination increased in the rubber ducks over time. When the ducks were washed with sodium hypochlorite, those microbial contaminations were not detected; but when the ducks were washed with an electrolyzed water, the standard plate counts and the heterotrophic plate counts were detected in the amount of 10<sup>3</sup> per duck in the wipe samples. Without proper washing of rubber ducks, bacteria and free-living amoeba can grow and colonize biofilms, and can thereby cause infection in humans. Also, microbial contamination inside ducks may reduce chlorination of the entire bathtub and cause bacterial infection such as Legionellosis from the bathtub water.</p>","PeriodicalId":8777,"journal":{"name":"Biocontrol science","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biocontrol science","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.4265/bio.26.187","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Microbiological contamination inside rubber ducks floating in the bathtub at a "duck bath" of a bathing facility was analyzed by examining bacterial and amoebic counts. The results of microbial tests, such as standard plate count, heterotrophic plate count and Legionella-LAMP (Loopmediated isothermal amplification) , showed that microbial contamination increased in the rubber ducks over time. When the ducks were washed with sodium hypochlorite, those microbial contaminations were not detected; but when the ducks were washed with an electrolyzed water, the standard plate counts and the heterotrophic plate counts were detected in the amount of 103 per duck in the wipe samples. Without proper washing of rubber ducks, bacteria and free-living amoeba can grow and colonize biofilms, and can thereby cause infection in humans. Also, microbial contamination inside ducks may reduce chlorination of the entire bathtub and cause bacterial infection such as Legionellosis from the bathtub water.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
游泳设施浴缸中漂浮橡皮鸭的微生物污染及清洗方法评价。
在一家洗浴设施的“鸭浴”中,通过检测细菌和阿米巴原虫的数量,分析了漂浮在浴缸里的橡皮鸭体内的微生物污染情况。标准平板计数、异养平板计数和军团菌- lamp(环介导等温扩增)等微生物检测结果显示,随着时间的推移,橡胶鸭体内的微生物污染有所增加。当用次氯酸钠清洗鸭子时,没有检测到这些微生物污染;但当用电解水清洗鸭时,在擦拭样品中检测到标准板计数和异养板计数,每只鸭的数量为103个。如果不对橡皮鸭进行适当的清洗,细菌和自由生活的变形虫就会生长并在生物膜上定植,从而导致人类感染。此外,鸭子体内的微生物污染可能会降低整个浴缸的氯化程度,并导致浴缸水中的军团菌病等细菌感染。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biocontrol science
Biocontrol science BIOTECHNOLOGY & APPLIED MICROBIOLOGY-
CiteScore
2.60
自引率
8.30%
发文量
21
审稿时长
>12 weeks
期刊介绍: The Biocontrol Science provides a medium for the publication of original articles, concise notes, and review articles on all aspects of science and technology of biocontrol.
期刊最新文献
Inactivation of SARS-CoV-2 by Commercially Available Disinfectants and Cleaners. Remote Bactericidal Effect of Anatase TiO2 Photocatalytic Nanoparticles Annealed with Low-Temperature O2 Plasma. Simple and Rapid Detection of ESBL blaSHV gene from an Urban River in Tokyo by Loop-Mediated Isothermal Amplification. Use of ATP Bioluminescence Assay to Evaluate Oral Streptococci. The Effectiveness of Neutral Electrolyzed Water for Decontaminating the Spray Nozzles of Electric Tankless and Tank-Type Warm-Water Bidet Toilet Seats.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1