Application of Semipermanent Cements and Conventional Cement with Modified Cementing Technique in Dental Implantology.

IF 1.4 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Acta Stomatologica Croatica Pub Date : 2021-12-01 DOI:10.15644/asc55/4/4
Valentina Veselinović, Saša Marin, Zoran Tatić, Nataša Trtić, Olivera Dolić, Tijana Adamović, Radmila Arbutina, Miodrag Šćepanović, Aleksandar Todorović
{"title":"Application of Semipermanent Cements and Conventional Cement with Modified Cementing Technique in Dental Implantology.","authors":"Valentina Veselinović,&nbsp;Saša Marin,&nbsp;Zoran Tatić,&nbsp;Nataša Trtić,&nbsp;Olivera Dolić,&nbsp;Tijana Adamović,&nbsp;Radmila Arbutina,&nbsp;Miodrag Šćepanović,&nbsp;Aleksandar Todorović","doi":"10.15644/asc55/4/4","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of this study was to evaluate the influence of artificial ageing on the retention force of original semipermanent cements, as well as the possibility of using conventional cements for semipermanent cementation with adequate modification of the cementing protocol.</p><p><strong>Materials and methods: </strong>Forty CoCrMo alloy crowns were divided in four groups (each group n=10) and fixed with two semipermanent cements (resin-based and glass ionomer-based cements) and one conventional (zinc phosphate), using conventional and modified cementation techniques on titanium abutments. The samples were stored in humid conditions for 24 hours at 37°C and subjected to thermocycling (500 cycles) and mechanical cyclic loading (7 days, 3, 6, 9 and 12 months function simulation). The cast crowns were removed and the retention force was recorded.</p><p><strong>Results: </strong>The highest initial retention force measured was for zinc-phosphate cement - conventional cementing (198,00±61,90 N), followed in descending order by zinc-phosphate cement - modified cementing technique (152,00±45,42 N), long term temporary cement - GC Fuji Temp LT (57,70±20,40 N), and semipermanent cement - Telio CS Cem Implant (56,10±18,68 N). After 12 months, the highest retention force measured was for zinc-phosphate cement - conventional cementing (88, 90±14, 45 N), followed by zinc-phosphate cement - modified cementing (48, 15±14,41N), semipermanent cement GC Fuji Temp LT (16,55±3,88 N) and Telio CS Cem Implant (15,55±5,52 N).</p><p><strong>Conclusions: </strong>Zinc-phosphate cement - modified cementing technique and original semipermanent cements can be recommended for conditional permanent cementing of implant supported crowns.</p><p><strong>Clinical relevance: </strong>The use of semipermanenet cements and zinc-phosphate cement - modified cementing technique provides a predictable retrievability of implant-supported crowns.</p>","PeriodicalId":7154,"journal":{"name":"Acta Stomatologica Croatica","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/1d/34/ASC_55(4)_367-379.PMC8734451.pdf","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Stomatologica Croatica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15644/asc55/4/4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 3

Abstract

Objectives: The aim of this study was to evaluate the influence of artificial ageing on the retention force of original semipermanent cements, as well as the possibility of using conventional cements for semipermanent cementation with adequate modification of the cementing protocol.

Materials and methods: Forty CoCrMo alloy crowns were divided in four groups (each group n=10) and fixed with two semipermanent cements (resin-based and glass ionomer-based cements) and one conventional (zinc phosphate), using conventional and modified cementation techniques on titanium abutments. The samples were stored in humid conditions for 24 hours at 37°C and subjected to thermocycling (500 cycles) and mechanical cyclic loading (7 days, 3, 6, 9 and 12 months function simulation). The cast crowns were removed and the retention force was recorded.

Results: The highest initial retention force measured was for zinc-phosphate cement - conventional cementing (198,00±61,90 N), followed in descending order by zinc-phosphate cement - modified cementing technique (152,00±45,42 N), long term temporary cement - GC Fuji Temp LT (57,70±20,40 N), and semipermanent cement - Telio CS Cem Implant (56,10±18,68 N). After 12 months, the highest retention force measured was for zinc-phosphate cement - conventional cementing (88, 90±14, 45 N), followed by zinc-phosphate cement - modified cementing (48, 15±14,41N), semipermanent cement GC Fuji Temp LT (16,55±3,88 N) and Telio CS Cem Implant (15,55±5,52 N).

Conclusions: Zinc-phosphate cement - modified cementing technique and original semipermanent cements can be recommended for conditional permanent cementing of implant supported crowns.

Clinical relevance: The use of semipermanenet cements and zinc-phosphate cement - modified cementing technique provides a predictable retrievability of implant-supported crowns.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
半永久骨水泥、常规骨水泥及改良骨水泥技术在种植牙中的应用。
目的:本研究的目的是评估人工老化对原始半永久性骨水泥固位力的影响,以及在适当修改骨水泥方案的情况下使用传统骨水泥进行半永久性骨水泥的可能性。材料和方法:40个CoCrMo合金冠分为四组(每组n=10),分别使用两种半永久性骨水泥(树脂基和玻璃离子基骨水泥)和一种常规骨水泥(磷酸锌)固定,在钛基基上使用常规和改良的骨水泥技术。样品在37°C潮湿条件下保存24小时,并进行热循环(500个循环)和机械循环加载(7天、3、6、9和12个月的功能模拟)。取出铸冠,记录固位力。结果:初始固位力最高的是磷酸锌水泥-常规固井(198,000±61,90 N),其次是磷酸锌水泥-改良固井技术(152,000±45,42 N),长期临时水泥- GC Fuji Temp LT(57,70±20,40 N),半永久性水泥- Telio CS Cem Implant(56,10±18,68 N)。12个月后,测得的固位力最高的是磷酸锌水泥-常规固井(88,90±14,45 N)。其次为磷酸锌水泥改良骨水泥(48,15±14,41N),半永久骨水泥GC Fuji Temp LT(16,55±3,88 N)和Telio CS Cem Implant(15,55±5,52 N)。结论:磷酸锌水泥改良骨水泥技术和原始半永久骨水泥可推荐用于种植体支撑冠的有条件永久骨水泥。临床意义:半永久性骨水泥和磷酸锌骨水泥改良骨水泥技术的应用提供了可预测的种植体支撑冠的可修复性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Acta Stomatologica Croatica
Acta Stomatologica Croatica DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.40
自引率
28.60%
发文量
32
审稿时长
12 weeks
期刊介绍: The Acta Stomatologica Croatica (ASCRO) is a leading scientific non-profit journal in the field of dental, oral and cranio-facial sciences during the past 44 years in Croatia. ASCRO publishes original scientific and clinical papers, preliminary communications, case reports, book reviews, letters to the editor and news. Review articles are published by invitation from the Editor-in-Chief by acclaimed professionals in distinct fields of dental medicine. All manuscripts are subjected to peer review process.
期刊最新文献
Assessment of Tooth Shade Measurement Precision and Consistency with Digital Photography Calibration System. Clinical Survival of Reduced-Thickness Monolithic Lithium-Disilicate Crowns: A 3-Year Randomized Controlled Trial. Dental Anxiety Among Students of the University of Rijeka, Croatia. Evaluation of Sella Turcica Variations in Lateral Cephalometric Radiographs and its Association with Malocclusion. Micro-Computed Tomography Analysis of Resin and Calcium Silicate Based Sealers Removal in Mandibular Molars Curved Canals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1