Miguel Mayo-Yáñez, Irma Cabo-Varela, Christian Calvo-Henríquez, Carlos Chiesa-Estomba, Jesús Herranz González-Botas
{"title":"Prevention of periprosthetic leakage with double flange voice prosthesis: a systematic review and management protocol proposal.","authors":"Miguel Mayo-Yáñez, Irma Cabo-Varela, Christian Calvo-Henríquez, Carlos Chiesa-Estomba, Jesús Herranz González-Botas","doi":"10.1080/14015439.2022.2042595","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To conduct a systematic review of the use and results of the Provox<sup>®</sup>Vega<sup>TM</sup>XtraSeal<sup>TM</sup> in the prevention of periprosthetic leakage and to propose a management protocol for this voice prosthesis.</p><p><strong>Methods: </strong>Systematic search based on the PRISMA Statement during February 2020. Keywords were double flange, periprosthetic leakage, voice prosthesis, and laryngectomy.</p><p><strong>Results: </strong>Four articles with 315 voice prosthesis (94 XtraSeal and 221 controls) in 55 patients were found. The XtraSeal mean duration was 114.28 ± 73.2 (CI 95%, 98.29-130.26) days compared to 102.98 ± 17.74 (CI 95%, 100.62-105.35) days of the control group. Out of 266 replacements, endoprosthetic leakage was the most frequent cause in both groups (62.41%). Periprosthetic leaks were less frequent in the XtraSeal (9.62%) than in the control group (22.43%).</p><p><strong>Conclusions: </strong>The XtraSeal could be effective in preventing periprosthetic leakage and lengthening the time between replacements. Studies with a robust methodology are necessary to confirm these results. Managing voice prosthesis is complex and requires a multidisciplinary and systematic approach by experienced professionals to reduce replacements and complications. Incorrect placement of the XtraSeal could cause a foreign body reaction and consequently inflammation, extrusion, or pressure lesions. The Tower of Hercules protocol: (1) Measurement of the tracheoesophageal fistula using the Provox<sup>®</sup> Measure, (2) Minimization of XtraSeal slack by avoiding the complete visualization of the prosthesis' blue ring, (3) Nasofibroscopic examination of the oesophageal wall confirming both flanges are in correct position; could prevent or minimize complications derived from the use of the XtraSeal.</p>","PeriodicalId":49903,"journal":{"name":"Logopedics Phoniatrics Vocology","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Logopedics Phoniatrics Vocology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/14015439.2022.2042595","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/2/25 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 4
Abstract
Objective: To conduct a systematic review of the use and results of the Provox®VegaTMXtraSealTM in the prevention of periprosthetic leakage and to propose a management protocol for this voice prosthesis.
Methods: Systematic search based on the PRISMA Statement during February 2020. Keywords were double flange, periprosthetic leakage, voice prosthesis, and laryngectomy.
Results: Four articles with 315 voice prosthesis (94 XtraSeal and 221 controls) in 55 patients were found. The XtraSeal mean duration was 114.28 ± 73.2 (CI 95%, 98.29-130.26) days compared to 102.98 ± 17.74 (CI 95%, 100.62-105.35) days of the control group. Out of 266 replacements, endoprosthetic leakage was the most frequent cause in both groups (62.41%). Periprosthetic leaks were less frequent in the XtraSeal (9.62%) than in the control group (22.43%).
Conclusions: The XtraSeal could be effective in preventing periprosthetic leakage and lengthening the time between replacements. Studies with a robust methodology are necessary to confirm these results. Managing voice prosthesis is complex and requires a multidisciplinary and systematic approach by experienced professionals to reduce replacements and complications. Incorrect placement of the XtraSeal could cause a foreign body reaction and consequently inflammation, extrusion, or pressure lesions. The Tower of Hercules protocol: (1) Measurement of the tracheoesophageal fistula using the Provox® Measure, (2) Minimization of XtraSeal slack by avoiding the complete visualization of the prosthesis' blue ring, (3) Nasofibroscopic examination of the oesophageal wall confirming both flanges are in correct position; could prevent or minimize complications derived from the use of the XtraSeal.
期刊介绍:
Logopedics Phoniatrics Vocology is an amalgamation of the former journals Scandinavian Journal of Logopedics & Phoniatrics and VOICE.
The intention is to cover topics related to speech, language and voice pathology as well as normal voice function in its different aspects. The Journal covers a wide range of topics, including:
Phonation and laryngeal physiology
Speech and language development
Voice disorders
Clinical measurements of speech, language and voice
Professional voice including singing
Bilingualism
Cleft lip and palate
Dyslexia
Fluency disorders
Neurolinguistics and psycholinguistics
Aphasia
Motor speech disorders
Voice rehabilitation of laryngectomees
Augmentative and alternative communication
Acoustics
Dysphagia
Publications may have the form of original articles, i.e. theoretical or methodological studies or empirical reports, of reviews of books and dissertations, as well as of short reports, of minor or ongoing studies or short notes, commenting on earlier published material. Submitted papers will be evaluated by referees with relevant expertise.