Recent Advances and Applications in Paper-Based Devices for Point-of-Care Testing.

IF 7 3区 化学 Q1 CHEMISTRY, ANALYTICAL Journal of Analysis and Testing Pub Date : 2022-01-01 Epub Date: 2022-01-13 DOI:10.1007/s41664-021-00204-w
Yue Hou, Cong-Cong Lv, Yan-Li Guo, Xiao-Hu Ma, Wei Liu, Yan Jin, Bao-Xin Li, Min Yang, Shi-Yin Yao
{"title":"Recent Advances and Applications in Paper-Based Devices for Point-of-Care Testing.","authors":"Yue Hou,&nbsp;Cong-Cong Lv,&nbsp;Yan-Li Guo,&nbsp;Xiao-Hu Ma,&nbsp;Wei Liu,&nbsp;Yan Jin,&nbsp;Bao-Xin Li,&nbsp;Min Yang,&nbsp;Shi-Yin Yao","doi":"10.1007/s41664-021-00204-w","DOIUrl":null,"url":null,"abstract":"<p><p>Point-of-care testing (POCT), as a portable and user-friendly technology, can obtain accurate test results immediately at the sampling point. Nowadays, microfluidic paper-based analysis devices (μPads) have attracted the eye of the public and accelerated the development of POCT. A variety of detection methods are combined with μPads to realize precise, rapid and sensitive POCT. This article mainly introduced the development of electrochemistry and optical detection methods on μPads for POCT and their applications on disease analysis, environmental monitoring and food control in the past 5 years. Finally, the challenges and future development prospects of μPads for POCT were discussed.</p>","PeriodicalId":14935,"journal":{"name":"Journal of Analysis and Testing","volume":"6 3","pages":"247-273"},"PeriodicalIF":7.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8755517/pdf/","citationCount":"46","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analysis and Testing","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s41664-021-00204-w","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 46

Abstract

Point-of-care testing (POCT), as a portable and user-friendly technology, can obtain accurate test results immediately at the sampling point. Nowadays, microfluidic paper-based analysis devices (μPads) have attracted the eye of the public and accelerated the development of POCT. A variety of detection methods are combined with μPads to realize precise, rapid and sensitive POCT. This article mainly introduced the development of electrochemistry and optical detection methods on μPads for POCT and their applications on disease analysis, environmental monitoring and food control in the past 5 years. Finally, the challenges and future development prospects of μPads for POCT were discussed.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于纸张的即时检测设备的最新进展和应用。
POCT (point -of-care testing)作为一种便携、用户友好的检测技术,可以在采样点立即获得准确的检测结果。目前,基于纸张的微流控分析装置(μPads)引起了公众的关注,加速了POCT的发展。多种检测方法与μ pad相结合,实现了精确、快速、灵敏的POCT。本文主要介绍了近5年来POCT μ pad电化学和光学检测方法的发展及其在疾病分析、环境监测和食品控制等方面的应用。最后,讨论了用于POCT的μ pad面临的挑战和未来的发展前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Analysis and Testing
Journal of Analysis and Testing CHEMISTRY, ANALYTICAL-
CiteScore
7.40
自引率
8.50%
发文量
43
期刊介绍: Journal of Analysis and Testing is a peer-reviewed journal devoted to providing an international academic platform for the publication of original research papers, rapid communications and critical reviews addressing all aspects of fundamental and applied analytical chemistry.The journal publishes original papers including but not limited to the following fields: Bioanalysis NanoanalysisMass spectrometrySpectroscopyChromatography ElectrochemistryEnvironmental analysisSurface and interface analysisMicroTASInstrumentation
期刊最新文献
Carbon Dots as “On–Off–On” Fluorescence Sensors for Selective and Consecutive Detection of 4-Nitrophenol and Cerium(IV) in Water Samples Design of a Novel Electrochemical Aptasensor Based on Molybdenum Disulfide Nanosheets for Lysozyme Detection Review of Electrochemical Sensors and Biosensors Based on First-Row Transition Metals, Their Oxides, and Noble Metals Nanoparticles Bifunctional Silicon Quantum Dots for Antibacterial Application and Highly Sensitive Detection of Tetracycline Development and Validation of an Impedimetric Sensor Modified with Molecularly Imprinted Polymer for Direct Determination of Bisphenol A in Bioanalytics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1