[Radiotherapy Dosimeter Calibration for Absorbed Dose to Water Using Medical Accelerators].

Morihito Shimizu
{"title":"[Radiotherapy Dosimeter Calibration for Absorbed Dose to Water Using Medical Accelerators].","authors":"Morihito Shimizu","doi":"10.11323/jjmp.41.3_134","DOIUrl":null,"url":null,"abstract":"<p><p>A calibration service using a medical accelerator has been launched to calibrate a radiotherapy dosimeter in terms of an absorbed dose to water. The radiotherapy dosimeter calibrated by the calibration service can measure the absorbed dose to water without a beam quality conversion factor. In this paper, an overview of the calibration service for a high-energy photon beam and a high-energy electron beam was described, as well as methods of absorbed dose measurement and cross-calibration using the calibrated radiotherapy dosimeter. And the development status of a dose standard for a particle beam was reported.</p>","PeriodicalId":13394,"journal":{"name":"Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics","volume":"41 3","pages":"134-142"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11323/jjmp.41.3_134","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A calibration service using a medical accelerator has been launched to calibrate a radiotherapy dosimeter in terms of an absorbed dose to water. The radiotherapy dosimeter calibrated by the calibration service can measure the absorbed dose to water without a beam quality conversion factor. In this paper, an overview of the calibration service for a high-energy photon beam and a high-energy electron beam was described, as well as methods of absorbed dose measurement and cross-calibration using the calibrated radiotherapy dosimeter. And the development status of a dose standard for a particle beam was reported.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[利用医用加速器校准放射治疗剂量计对水的吸收剂量]。
本署已推出一项使用医用加速器的校正服务,以水的吸收剂量来校正放射治疗剂量计。由校正服务校正的放射治疗剂量计可以测量吸收到水中的剂量,而无需光束质量转换因子。本文概述了高能光子束和高能电子束的校准服务,以及使用校准放射剂量计进行吸收剂量测量和交叉校准的方法。并介绍了粒子束剂量标准的制定情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Technical Report: Quality Assurance for 125I Seed Sources in Permanent Prostate Brachytherapy]. [INTRODUCTION OF AWARDS OF RPT IN 2021]. [EDITOR'S NOTE]. [Effects of sample size and data augmentation on U-Net-based automatic segmentation of various organs].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1