Biodegradable polymer Biolimus-eluting stent (Nobori®) for the treatment of coronary artery lesions: review of concept and clinical results.

IF 1.3 Q4 ENGINEERING, BIOMEDICAL Medical Devices-Evidence and Research Pub Date : 2014-02-27 eCollection Date: 2014-01-01 DOI:10.2147/MDER.S44051
Guillaume Schurtz, Cédric Delhaye, Christopher Hurt, Henri Thieuleux, Gilles Lemesle
{"title":"Biodegradable polymer Biolimus-eluting stent (Nobori®) for the treatment of coronary artery lesions: review of concept and clinical results.","authors":"Guillaume Schurtz,&nbsp;Cédric Delhaye,&nbsp;Christopher Hurt,&nbsp;Henri Thieuleux,&nbsp;Gilles Lemesle","doi":"10.2147/MDER.S44051","DOIUrl":null,"url":null,"abstract":"<p><p>First-generation drug-eluting stents have raised concerns regarding the risk of late and very late stent thrombosis compared with bare metal stents and require prolonged dual antiplatelet therapy. Despite extensive investigations, the physiopathology of these late events remains incompletely understood. Aside from patient- and lesion-related risk factors, stent polymer has been cited as one of the potential causes. In fact, the persistence of durable polymer after complete drug release has been shown to be responsible for local hypersensitivity and inflammatory reactions. Third-generation drug-eluting stents with more biocompatible or biodegradable polymers have subsequently been developed to address this problem. In this article, we evaluate and discuss the concept and clinical results (safety and efficacy) of a third-generation drug-eluting stent with biodegradable polymer: the Nobori® stent. </p>","PeriodicalId":47140,"journal":{"name":"Medical Devices-Evidence and Research","volume":" ","pages":"35-43"},"PeriodicalIF":1.3000,"publicationDate":"2014-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2147/MDER.S44051","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Devices-Evidence and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/MDER.S44051","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2014/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 13

Abstract

First-generation drug-eluting stents have raised concerns regarding the risk of late and very late stent thrombosis compared with bare metal stents and require prolonged dual antiplatelet therapy. Despite extensive investigations, the physiopathology of these late events remains incompletely understood. Aside from patient- and lesion-related risk factors, stent polymer has been cited as one of the potential causes. In fact, the persistence of durable polymer after complete drug release has been shown to be responsible for local hypersensitivity and inflammatory reactions. Third-generation drug-eluting stents with more biocompatible or biodegradable polymers have subsequently been developed to address this problem. In this article, we evaluate and discuss the concept and clinical results (safety and efficacy) of a third-generation drug-eluting stent with biodegradable polymer: the Nobori® stent.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于治疗冠状动脉病变的可生物降解聚合物biolimus洗脱支架(Nobori®):概念和临床结果的回顾
与裸金属支架相比,第一代药物洗脱支架引起了对晚期和极晚期支架血栓形成风险的担忧,并且需要长时间的双重抗血小板治疗。尽管进行了广泛的调查,但这些晚期事件的生理病理机制仍不完全清楚。除了患者和病变相关的危险因素外,支架聚合物也被认为是潜在的原因之一。事实上,持久聚合物在药物完全释放后的持续存在已被证明是局部过敏和炎症反应的原因。第三代药物洗脱支架具有更多的生物相容性或可生物降解的聚合物,随后被开发来解决这个问题。在本文中,我们评估和讨论了第三代生物可降解聚合物药物洗脱支架的概念和临床结果(安全性和有效性):Nobori®支架。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Medical Devices-Evidence and Research
Medical Devices-Evidence and Research ENGINEERING, BIOMEDICAL-
CiteScore
2.80
自引率
0.00%
发文量
41
审稿时长
16 weeks
期刊最新文献
Initial Validation of the NOL Nociception Level Index® Monitoring System in Black and Multiracial People. Potential of Aluminum Drug Packages with Press-Through Packaging Considering Usability for a Wide Range of Users. The Application Effect of Fine Management Combined with Man-Machine Fixation Mode in Reducing the Attrition Rate of Laparoscopic Instruments-A Non-Randomized, Concurrent Controlled Study. Patients with Growth-Related Disorders and Caregivers Prefer the Somapacitan Device to the Somatrogon Device: Results from a Randomized Crossover Study Assessing Device Preference and Ease of Use Following Simulated Injections. May Glymphatic Drainage Improve Life Quality in Progressive Multiple Sclerosis Outpatients?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1