Evaluation of Fiber Post Adhesion to Root Dentin Achieved with Different Composite Cements: 1-year In Vitro Results.

IF 4.7 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2022-03-24 DOI:10.3290/j.jad.b2838131
Uros Josic, Claudia Mazzitelli, Tatjana Maravic, Allegra Comba, Eric Mayer-Santos, Federica Florenzano, Lorenzo Breschi, Annalisa Mazzoni
{"title":"Evaluation of Fiber Post Adhesion to Root Dentin Achieved with Different Composite Cements: 1-year In Vitro Results.","authors":"Uros Josic, Claudia Mazzitelli, Tatjana Maravic, Allegra Comba, Eric Mayer-Santos, Federica Florenzano, Lorenzo Breschi, Annalisa Mazzoni","doi":"10.3290/j.jad.b2838131","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate push-out bond strength (PBS) and interfacial nanoleakage (NL) of adhesively luted fiber posts using different composite cements and polymerization protocols.</p><p><strong>Material and methods: </strong>100 premolars were endodontically treated and assigned to the following groups (n=10): RelyX Universal light-cure (3M Oral Care); RelyX Universal self-cure (3M Oral Care); Maxcem Elite Chroma light-cure (Kerr); Maxcem Elite Chroma self-cure (Kerr); Calibra Universal light-cure (Dentsply Sirona); Calibra Universal self-cure (Dentsply Sirona); Multilink Automix light cure (Ivoclar Vivadent); Multilink Automix self-cure (Ivoclar Vivadent); Luxacore Z Dual light-cure (DMG); Luxacore Z Dual self-cure (DMG). Half of the teeth from each group were subjected to the PBS test after 24 h (T0), while the other half was tested after 12 months (T12) of artificial saliva aging. An additional 4 teeth per group were prepared for NL expression. PBS values were analyzed using multivariate ANOVA and Tukey's post-hoc test. NL scores were analyzed using chi-squared tests (α = 0.05).</p><p><strong>Results: </strong>Statistical analysis revealed that the variables \"cement\" and \"aging\" significantly influenced PBS (p < 0.05), but not \"polymerization\" and \"root region\" (p > 0.05). Significantly lower PBS values (p < 0.05) were detected for the Calibra Universal groups compared to other cements, while the RelyX Universal groups performed equally well (p > 0.05) or better than other cements (p < 0.05). At T12, PBS values increased in the majority of groups, irrespective of root region (p < 0.05). Differences in NL expression were present at T0, and in general, the aging process increased marginal infiltration.</p><p><strong>Conclusion: </strong>Aging and choice of composite cement influenced PBS, while root region and polymerization protocol seemed to have no influence on posts' resistance to dislodgment.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":" ","pages":"95-104"},"PeriodicalIF":4.7000,"publicationDate":"2022-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11734297/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3290/j.jad.b2838131","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate push-out bond strength (PBS) and interfacial nanoleakage (NL) of adhesively luted fiber posts using different composite cements and polymerization protocols.

Material and methods: 100 premolars were endodontically treated and assigned to the following groups (n=10): RelyX Universal light-cure (3M Oral Care); RelyX Universal self-cure (3M Oral Care); Maxcem Elite Chroma light-cure (Kerr); Maxcem Elite Chroma self-cure (Kerr); Calibra Universal light-cure (Dentsply Sirona); Calibra Universal self-cure (Dentsply Sirona); Multilink Automix light cure (Ivoclar Vivadent); Multilink Automix self-cure (Ivoclar Vivadent); Luxacore Z Dual light-cure (DMG); Luxacore Z Dual self-cure (DMG). Half of the teeth from each group were subjected to the PBS test after 24 h (T0), while the other half was tested after 12 months (T12) of artificial saliva aging. An additional 4 teeth per group were prepared for NL expression. PBS values were analyzed using multivariate ANOVA and Tukey's post-hoc test. NL scores were analyzed using chi-squared tests (α = 0.05).

Results: Statistical analysis revealed that the variables "cement" and "aging" significantly influenced PBS (p < 0.05), but not "polymerization" and "root region" (p > 0.05). Significantly lower PBS values (p < 0.05) were detected for the Calibra Universal groups compared to other cements, while the RelyX Universal groups performed equally well (p > 0.05) or better than other cements (p < 0.05). At T12, PBS values increased in the majority of groups, irrespective of root region (p < 0.05). Differences in NL expression were present at T0, and in general, the aging process increased marginal infiltration.

Conclusion: Aging and choice of composite cement influenced PBS, while root region and polymerization protocol seemed to have no influence on posts' resistance to dislodgment.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估使用不同复合材料粘结剂实现的纤维桩与牙根的粘附性:一年的体外结果
目的:评估使用不同复合树脂和聚合方案的粘结纤维桩的推出粘结强度(PBS)和界面纳米渗漏(NL)。材料和方法:对100颗前臼齿进行根管治疗,并将其分配到以下组别(n=10):RelyX Universal光固化(3M口腔护理公司);RelyX Universal自固化(3M口腔护理公司);Maxcem Elite Chroma光固化(Kerr公司);Maxcem Elite Chroma自固化(Kerr公司);Calibra Universal光固化(Dentsply Sirona公司);Calibra Universal 光固化(Dentsply Sirona);Multilink Automix 光固化(Ivoclar Vivadent);Multilink Automix 自固化(Ivoclar Vivadent);Luxacore Z 双光固化(DMG);Luxacore Z 双自固化(DMG)。每组一半的牙齿在 24 小时后(T0)进行 PBS 测试,另一半在人工唾液老化 12 个月后(T12)进行测试。每组另外准备 4 颗牙齿用于 NL 表达。PBS值采用多元方差分析和Tukey's事后检验进行分析。NL 评分采用卡方检验(α = 0.05)进行分析:统计分析显示,"水门汀 "和 "老化 "这两个变量对 PBS 有显著影响(p < 0.05),但 "聚合 "和 "根区 "这两个变量对 PBS 没有显著影响(p > 0.05)。与其他水门汀相比,Calibra Universal 组的 PBS 值明显较低(p < 0.05),而 RelyX Universal 组的表现与其他水门汀相当(p > 0.05)或更好(p < 0.05)。在 T12 期,大多数组的 PBS 值都有所增加,与根区无关(p < 0.05)。T0时NL的表达存在差异,总的来说,老化过程增加了边缘浸润:结论:老化和选择的复合材料粘接剂会影响 PBS,而根区和聚合方案似乎对桩体的抗脱落性没有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊介绍: ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.
期刊最新文献
Pullulan Coating Preserves High Conductivity in Cable Bacteria Wires. Polypyrrole-Coated Microneedle Platform for Offline Electrochemical Detection of Interferon-Alpha in Interstitial Fluid. 2D MXene-Based Mesoporous Silica Nanoplatform for Autophagy Inhibition and Enhanced Photothermal Therapy of Hepatoblastoma. Chia Seed Mucilage-Based Bilayer Sponges Containing Zinc Oxide Nanoparticles for Wound Dressing. Quaternized Chitosan-Ferulic Acid-Based Nanomicelles for Dimethoxycurcumin Delivery and Synergistic Colorectal Adenocarcinoma Therapy with 5-Fluorouracil.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1