The association of ultrasound assessment of gallbladder wall thickness with dengue fever severity.

IF 3.4 Q2 Medicine Ultrasound Journal Pub Date : 2022-03-24 DOI:10.1186/s13089-022-00262-w
Mohd Anwar Ibrahim, Siti Suhaila Hamzah, Julina Md Noor, Mohamad Iqhbal Kunji Mohamad, Mohd Fazrul Mokhtar, Mohamad Rodi Isa, Mohammed Fauzi Abdul Rani
{"title":"The association of ultrasound assessment of gallbladder wall thickness with dengue fever severity.","authors":"Mohd Anwar Ibrahim,&nbsp;Siti Suhaila Hamzah,&nbsp;Julina Md Noor,&nbsp;Mohamad Iqhbal Kunji Mohamad,&nbsp;Mohd Fazrul Mokhtar,&nbsp;Mohamad Rodi Isa,&nbsp;Mohammed Fauzi Abdul Rani","doi":"10.1186/s13089-022-00262-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the association between ultrasound assessment of gallbladder wall thickness (GBWT) among severe dengue patients and dengue patients with warning signs to their clinical outcomes.</p><p><strong>Methods: </strong>A prospective, cross-sectional study involving adult dengue patients presented to our emergency department between March until September 2018. The patients were classified based on WHO classification. A gallbladder wall scan was performed on all patients.</p><p><strong>Results: </strong>A total of 44 patients were enrolled into the study; majority of the patients with GBWT had severe dengue, significantly more than the dengue patients with warning signs (90.5% sensitivity; 69.6% specificity). The sensitivity of GBWT in determining admission to critical care areas or general ward was 100% with a specificity of 62.1%. Our analysis showed that the two variables significant in determining the severity of dengue were age (p = 0.045) and GBWT (p < 0.001). Both factors together gave 81.0% sensitivity and 78.3% specificity in predicting patients for severe dengue. The receiver operator characteristic curve revealed that using variable GBWT status can discriminate 87.1% (95%CI 66.3, 93.7%) of having severe dengue or dengue with warning signs.</p><p><strong>Conclusion: </strong>The finding of GBWT when consolidated with other clinical parameters may assist clinicians to perform risk stratification in the emergency department and become another adjunct to the assessment of severe dengue.</p>","PeriodicalId":36911,"journal":{"name":"Ultrasound Journal","volume":" ","pages":"13"},"PeriodicalIF":3.4000,"publicationDate":"2022-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8948308/pdf/","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13089-022-00262-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

Abstract

Objectives: To evaluate the association between ultrasound assessment of gallbladder wall thickness (GBWT) among severe dengue patients and dengue patients with warning signs to their clinical outcomes.

Methods: A prospective, cross-sectional study involving adult dengue patients presented to our emergency department between March until September 2018. The patients were classified based on WHO classification. A gallbladder wall scan was performed on all patients.

Results: A total of 44 patients were enrolled into the study; majority of the patients with GBWT had severe dengue, significantly more than the dengue patients with warning signs (90.5% sensitivity; 69.6% specificity). The sensitivity of GBWT in determining admission to critical care areas or general ward was 100% with a specificity of 62.1%. Our analysis showed that the two variables significant in determining the severity of dengue were age (p = 0.045) and GBWT (p < 0.001). Both factors together gave 81.0% sensitivity and 78.3% specificity in predicting patients for severe dengue. The receiver operator characteristic curve revealed that using variable GBWT status can discriminate 87.1% (95%CI 66.3, 93.7%) of having severe dengue or dengue with warning signs.

Conclusion: The finding of GBWT when consolidated with other clinical parameters may assist clinicians to perform risk stratification in the emergency department and become another adjunct to the assessment of severe dengue.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声评估胆囊壁厚度与登革热严重程度的关系。
目的:探讨重症登革热患者超声胆囊壁厚度(GBWT)与有警示体征的登革热患者临床预后的关系。方法:一项前瞻性横断面研究,纳入2018年3月至9月期间在急诊科就诊的成年登革热患者。根据WHO分类对患者进行分类。所有患者均行胆囊壁扫描。结果:共有44例患者入组;绝大多数GBWT患者为重度登革热,显著高于有警示体征的登革热患者(敏感性90.5%;特异性69.6%)。GBWT在确定是否入住重症监护区或普通病房方面的敏感性为100%,特异性为62.1%。我们的分析显示,确定登革热严重程度的两个重要变量是年龄(p = 0.045)和GBWT (p)。结论:GBWT的发现与其他临床参数结合后,可以帮助临床医生在急诊科进行风险分层,并成为评估登革热严重程度的另一个辅助因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ultrasound Journal
Ultrasound Journal Health Professions-Radiological and Ultrasound Technology
CiteScore
6.80
自引率
2.90%
发文量
45
审稿时长
22 weeks
期刊最新文献
Quantitative valve motion assessment in adolescents using point-of-care ultrasound: short communication. A framework for flow time measured by Doppler ultrasound. Exploring the adoption of diaphragm and lung ultrasound (DLUS) by physiotherapists, physical therapists, and respiratory therapists: an updated scoping review. Comparison of two point-of-care lung ultrasound techniques and their associated outcomes for bronchiolitis in the pediatric emergency department. Evaluation of a modified venous excess ultrasound (VExUS) protocol for estimation of venous congestion: a cohort study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1