James T Isaacs, Philip J Almeter, Bradley S Henderson, Aaron N Hunter, Thomas L Platt, Robert A Lodder
{"title":"Spectrometric Analysis of Process Variations in Remifentanil.","authors":"James T Isaacs, Philip J Almeter, Bradley S Henderson, Aaron N Hunter, Thomas L Platt, Robert A Lodder","doi":"10.6084/m9.figshare.21109093","DOIUrl":null,"url":null,"abstract":"<p><p>ULTIVA® (remifentanil hydrochloride) is a sterile, nonpyrogenic, preservative-free, white to off-white lyophilized powder for intravenous (IV) administration after reconstitution and dilution. Each vial contains 1, 2, or 5 mg of remifentanil base; 15 mg glycine; and hydrochloric acid to buffer the solutions to a nominal pH of 3 after reconstitution. ULTIVA® is a μ-opioid agonist with rapid onset and peak effect, and short duration of action. Intra-lot and inter-lot variability in the spectra of ULTIVA® was measured in the Drug Quality Study (DQS) using Fourier transform near-infrared spectrometry (FTNIR). In 6 vials sampled, 1 came from lot 220453F while 5 came from lot 30020BF. The 1 vial sampled from lot 220453F appeared 122 multidimensional SDs from the other vials from lot 30020BF, suggesting that it represents a different formulation or material. Consequently, additional spectra from other lots were analyzed. Spectra of 90 vials from 9 lots in the spectral library contained vials that were outside the main group (50.3 SDs using a subcluster detection test), suggesting that the 35 library vials (39% of the total) contain different materials from the other 55 vials.</p>","PeriodicalId":72698,"journal":{"name":"Contact in context","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9520611/pdf/nihms-1836546.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contact in context","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6084/m9.figshare.21109093","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/9/14 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
ULTIVA® (remifentanil hydrochloride) is a sterile, nonpyrogenic, preservative-free, white to off-white lyophilized powder for intravenous (IV) administration after reconstitution and dilution. Each vial contains 1, 2, or 5 mg of remifentanil base; 15 mg glycine; and hydrochloric acid to buffer the solutions to a nominal pH of 3 after reconstitution. ULTIVA® is a μ-opioid agonist with rapid onset and peak effect, and short duration of action. Intra-lot and inter-lot variability in the spectra of ULTIVA® was measured in the Drug Quality Study (DQS) using Fourier transform near-infrared spectrometry (FTNIR). In 6 vials sampled, 1 came from lot 220453F while 5 came from lot 30020BF. The 1 vial sampled from lot 220453F appeared 122 multidimensional SDs from the other vials from lot 30020BF, suggesting that it represents a different formulation or material. Consequently, additional spectra from other lots were analyzed. Spectra of 90 vials from 9 lots in the spectral library contained vials that were outside the main group (50.3 SDs using a subcluster detection test), suggesting that the 35 library vials (39% of the total) contain different materials from the other 55 vials.