Evaluation of the degradation of two bioabsorbable interference screws: an in-vivo study in sheep.

IF 1.1 4区 医学 Q3 SURGERY Acta cirurgica brasileira Pub Date : 2022-06-27 eCollection Date: 2022-01-01 DOI:10.1590/acb370405
Paulo Sérgio Scorsato, Sheila Canevese Rahal, Tania Mary Cestari, Maria Jaqueline Mamprim, Danuta Pulz Doiche, Daniel de Bortoli Teixeira, Rafael Cerântola Siqueira, Marcílio Felix
{"title":"Evaluation of the degradation of two bioabsorbable interference screws: an in-vivo study in sheep.","authors":"Paulo Sérgio Scorsato,&nbsp;Sheila Canevese Rahal,&nbsp;Tania Mary Cestari,&nbsp;Maria Jaqueline Mamprim,&nbsp;Danuta Pulz Doiche,&nbsp;Daniel de Bortoli Teixeira,&nbsp;Rafael Cerântola Siqueira,&nbsp;Marcílio Felix","doi":"10.1590/acb370405","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate in-vivo degradation of two bioabsorbable interference screws.</p><p><strong>Methods: </strong>Twenty-two crossbred Santa Inês ewes were used. A poly-DL-lactide (PDLLA) screw (70%/30%) was inserted in the right pelvic limb, and a PDLLA screw (70%) + β-tri-calcium phosphate (β-TCP) (30%) in the left pelvic limb. Animals were euthanized at one, four, seven and a half and 18 months after surgery. Plain radiography, computed tomography (CT), microCT, and histological analysis were accomplished.</p><p><strong>Results: </strong>PDLLA screw was hypodense at all evaluation moments, but with progressive density increase along the central axis, whereas PDLLA/β-TCP was initially hyperdense and progressively lost this characteristic. No adverse reactions were observed on histological evaluation.</p><p><strong>Conclusions: </strong>The inclusion of β-TCP favors screw degradation since the PDLLA/β-TCP screws evidenced a more intense degradation process than the PDLLA screws at the last evaluation. PDLLA screws showed higher bone production, evident around the screw thread, inside the lateral perforations, and in the central canal, whereas the PDLLA/β-TCP screws presented less bone tissue at the implantation site.</p>","PeriodicalId":6992,"journal":{"name":"Acta cirurgica brasileira","volume":"37 4","pages":"e370405"},"PeriodicalIF":1.1000,"publicationDate":"2022-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9239560/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta cirurgica brasileira","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/acb370405","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate in-vivo degradation of two bioabsorbable interference screws.

Methods: Twenty-two crossbred Santa Inês ewes were used. A poly-DL-lactide (PDLLA) screw (70%/30%) was inserted in the right pelvic limb, and a PDLLA screw (70%) + β-tri-calcium phosphate (β-TCP) (30%) in the left pelvic limb. Animals were euthanized at one, four, seven and a half and 18 months after surgery. Plain radiography, computed tomography (CT), microCT, and histological analysis were accomplished.

Results: PDLLA screw was hypodense at all evaluation moments, but with progressive density increase along the central axis, whereas PDLLA/β-TCP was initially hyperdense and progressively lost this characteristic. No adverse reactions were observed on histological evaluation.

Conclusions: The inclusion of β-TCP favors screw degradation since the PDLLA/β-TCP screws evidenced a more intense degradation process than the PDLLA screws at the last evaluation. PDLLA screws showed higher bone production, evident around the screw thread, inside the lateral perforations, and in the central canal, whereas the PDLLA/β-TCP screws presented less bone tissue at the implantation site.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评价两种生物可吸收干扰螺钉的降解:绵羊体内研究。
目的:评价两种生物可吸收干扰螺钉的体内降解情况。方法:选用杂交Santa Inês母羊22只。右侧骨盆肢体置入聚乳酸(PDLLA)螺钉(70%/30%),左侧骨盆肢体置入PDLLA螺钉(70%)+ β-三磷酸钙(β-TCP)(30%)。动物分别在手术后1个月、4个月、7个半月和18个月被安乐死。平片、计算机断层扫描(CT)、微CT和组织学分析完成。结果:PDLLA螺钉在所有评估时刻均为低密度,但密度沿中轴逐渐增加,而PDLLA/β-TCP最初为高密度,并逐渐丧失这种特征。组织学检查未见不良反应。结论:β-TCP的加入有利于螺钉降解,因为PDLLA/β-TCP螺钉的降解过程比PDLLA螺钉的降解过程更强烈。PDLLA螺钉的成骨量较高,在螺纹周围、外侧孔内和中央管中表现明显,而PDLLA/β-TCP螺钉在种植部位的骨组织较少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.90
自引率
9.10%
发文量
60
审稿时长
3-8 weeks
期刊介绍: Information not localized
期刊最新文献
Associations of DNA-methylation measures of biological aging with social disparities in child and adolescent mental health. Tridimensional models and radiographic study of dorsal laminectomy and thoracolumbar hemilaminectomy in dogs. Pancreatic cancer orthotopic graft in a murine model. ERRATA. Protective effect of Guanxin Danshen formula on myocardial ischemiareperfusion injury in rats.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1