Comparison of Anterior Segment Measurements with a New Multifunctional Unit and Five Other Devices.

Q3 Medicine Korean Journal of Ophthalmology : KJO Pub Date : 2022-08-01 Epub Date: 2022-06-15 DOI:10.3341/kjo.2022.0025
Bo Yi Kim, Ikhyun Jun
{"title":"Comparison of Anterior Segment Measurements with a New Multifunctional Unit and Five Other Devices.","authors":"Bo Yi Kim,&nbsp;Ikhyun Jun","doi":"10.3341/kjo.2022.0025","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the clinical availability of a multifunctional ocular biometric unit, MR-6000, for simultaneous keratometry, tonometry, topography, and pachymetry evaluation, and compare anterior segment measurements with five other devices: autokeratometer (KR-1), Scheimpflug camera (Pentacam HR), swept-source optical coherence tomography (IOLMaster 700), Placido disk scanning-slit topography (Orbscan II), and noncontact tonometry (FT-1000).</p><p><strong>Methods: </strong>Thirty eyes from thirty patients who visited Severance Hospital for cataract surgery were examined using MR6000 and the other devices. The mean keratometry, central corneal thickness (CCT), white-to-white (WTW) distance, and intraocular pressure (IOP) values were compared. Repeated measures analysis of variance, Wilcoxon signed-rank test, intraclass correlation coefficient (ICC), and Bland-Altman plot were used to assess the correlation and agreement between devices.</p><p><strong>Results: </strong>Thirty eyes of thirty patients were evaluated. Statistically significant differences in mean keratometry between MR6000, KR-1, Pentacam HR, and IOLMaster 700 were not observed (p > 0.05). All five devices, including Orbscan II, had almost perfect agreement in measuring keratometry (ICC > 0.80, p < 0.05). CCT measured by MR-6000 was significantly different from that of Pentacam HR and Orbscan II measurements (p < 0.05) but correlated with that of Pentacam HR and Orbscan II measurements (ICC > 0.60, p < 0.05). The WTW distance measured by MR-6000 was not significantly different from that measured by IOLMaster 700 but was different from that measured by Orbscan II. IOP measured by MR-6000 was not correlated with FT-1000.</p><p><strong>Conclusions: </strong>Keratometric values obtained through MR-6000 can be used interchangeably with other devices based on good correlation and agreement. However, the CCT, WTW, and IOP values were not interchangeable with a single multifunctional unit for cataract surgery preoperative examination.</p>","PeriodicalId":17883,"journal":{"name":"Korean Journal of Ophthalmology : KJO","volume":" ","pages":"338-349"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/f4/f9/kjo-2022-0025.PMC9388890.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Ophthalmology : KJO","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3341/kjo.2022.0025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/6/15 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: To evaluate the clinical availability of a multifunctional ocular biometric unit, MR-6000, for simultaneous keratometry, tonometry, topography, and pachymetry evaluation, and compare anterior segment measurements with five other devices: autokeratometer (KR-1), Scheimpflug camera (Pentacam HR), swept-source optical coherence tomography (IOLMaster 700), Placido disk scanning-slit topography (Orbscan II), and noncontact tonometry (FT-1000).

Methods: Thirty eyes from thirty patients who visited Severance Hospital for cataract surgery were examined using MR6000 and the other devices. The mean keratometry, central corneal thickness (CCT), white-to-white (WTW) distance, and intraocular pressure (IOP) values were compared. Repeated measures analysis of variance, Wilcoxon signed-rank test, intraclass correlation coefficient (ICC), and Bland-Altman plot were used to assess the correlation and agreement between devices.

Results: Thirty eyes of thirty patients were evaluated. Statistically significant differences in mean keratometry between MR6000, KR-1, Pentacam HR, and IOLMaster 700 were not observed (p > 0.05). All five devices, including Orbscan II, had almost perfect agreement in measuring keratometry (ICC > 0.80, p < 0.05). CCT measured by MR-6000 was significantly different from that of Pentacam HR and Orbscan II measurements (p < 0.05) but correlated with that of Pentacam HR and Orbscan II measurements (ICC > 0.60, p < 0.05). The WTW distance measured by MR-6000 was not significantly different from that measured by IOLMaster 700 but was different from that measured by Orbscan II. IOP measured by MR-6000 was not correlated with FT-1000.

Conclusions: Keratometric values obtained through MR-6000 can be used interchangeably with other devices based on good correlation and agreement. However, the CCT, WTW, and IOP values were not interchangeable with a single multifunctional unit for cataract surgery preoperative examination.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种新型多功能装置与其他五种装置测量前段的比较。
目的:评估多功能眼生物测量设备MR-6000的临床可用性,用于同时进行角膜测量、眼压测量、地形测量和视厚测量评估,并将前段测量与其他五种设备进行比较:自动角膜测量仪(dr -1)、Scheimpflug相机(Pentacam HR)、扫描源光学相干断层扫描(IOLMaster 700)、Placido盘扫描-裂隙地形扫描(Orbscan II)和非接触式眼压测量仪(FT-1000)。方法:对30例在Severance医院行白内障手术的患者30只眼进行MR6000及其他仪器检查。比较平均角膜度数、角膜中央厚度(CCT)、白到白(WTW)距离和眼压(IOP)值。使用重复测量方差分析、Wilcoxon符号秩检验、类内相关系数(ICC)和Bland-Altman图来评估设备之间的相关性和一致性。结果:对30例患者的30只眼进行了检查。MR6000、KR-1、Pentacam HR和IOLMaster 700的平均角膜密度测定无统计学差异(p > 0.05)。包括Orbscan II在内的五种仪器在测量角膜度数方面几乎完全一致(ICC > 0.80, p < 0.05)。MR-6000测量的CCT与Pentacam HR和Orbscan II测量值差异有统计学意义(p < 0.05),但与Pentacam HR和Orbscan II测量值相关(ICC > 0.60, p < 0.05)。MR-6000测量的WTW距离与IOLMaster 700测量的WTW距离差异不显著,但与Orbscan II测量的WTW距离差异不显著。MR-6000测量的IOP与FT-1000无相关性。结论:MR-6000获得的角膜测量值与其他仪器具有良好的相关性和一致性,可互换使用。然而,CCT、WTW和IOP值在白内障手术术前检查中不能与单一多功能装置互换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Korean Journal of Ophthalmology : KJO
Korean Journal of Ophthalmology : KJO Medicine-Ophthalmology
CiteScore
2.40
自引率
0.00%
发文量
84
期刊最新文献
Restoration of Corneal Transparency in a Patient with Corneal Scarring Using Mesenchyme Stem Cells: A Case Report. One-Year Outcomes of Ab Externo XEN45 Gel Stent Implantation with an Open Conjunctiva Approach in Patients with Open-Angle Glaucoma. Comparison of Accuracy of Six Modern Intraocular Lens Power Calculation Formulas. Clinical Outcomes of Descemet Membrane Endothelial Keratoplasty Using a Preloaded Imported Graft. Short-term Efficacy and Safety of Intravitreal Brolucizumab Injection for Treatment-Naive Exudate Age-related Macular Degeneration: A Multicenter Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1