{"title":"Bond Strengths of Universal Adhesives to Dentin Contaminated with a Hemostatic Agent.","authors":"Sawaphon Noppawong, Jaikaew Pratabsingha, Chanida Thamsoonthorn, Weeranun Vichathai, Pipop Saikaew","doi":"10.3290/j.jad.b3601769","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the microtensile bond strength (µTBS) of three universal adhesives to dentin contaminated with a hemostatic agent.</p><p><strong>Materials and methods: </strong>Ninety-six human premolars were cut to expose mid-coronal dentin. The teeth were randomly divided into a control group (uncontaminated dentin) and an experimental group in which a hemostatic agent was applied (contaminated dentin). Each group was further divided into 6 subgroups according to universal adhesives - SBU (Single Bond Universal), OPU (OptiBond Universal), CBQ (Clearfil Universal Bond Quick) - and etching mode, either etch-and-rinse (ER) or self-etch (SE). Following adhesive application, composite was placed in two increments and light cured. The specimens were stored in distilled water at 37°C for 24 h. The µTBS test was performed using a universal testing machine. Failure mode was assessed using a light microscope. The data were statistically analyzed using three-way ANOVA followed by Scheffe's test (p < 0.05). The resin-dentin interface was observed using scanning electron microscopy.</p><p><strong>Results: </strong>Significantly lower bond strength was observed when the universal adhesives were bonded to contaminated dentin in SE mode (p < 0.05). In contrast, the µTBS of the universal adhesives in ER mode was not affected by contamination (p > 0.05). The µTBS of CBQ to contaminated dentin was significantly lower than that of the other adhesives. Observation of the resin-dentin interface revealed limited resin penetration when the universal adhesive was applied in SE mode on contaminated dentin.</p><p><strong>Conclusion: </strong>Contaminating the dentin with a hemostatic agent significantly reduced the µTBS of the universal adhesives in SE mode. However, this adverse effect was not found when the universal adhesives were used in ER mode.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":" ","pages":"421-426"},"PeriodicalIF":4.7000,"publicationDate":"2022-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11734302/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3290/j.jad.b3601769","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate the microtensile bond strength (µTBS) of three universal adhesives to dentin contaminated with a hemostatic agent.
Materials and methods: Ninety-six human premolars were cut to expose mid-coronal dentin. The teeth were randomly divided into a control group (uncontaminated dentin) and an experimental group in which a hemostatic agent was applied (contaminated dentin). Each group was further divided into 6 subgroups according to universal adhesives - SBU (Single Bond Universal), OPU (OptiBond Universal), CBQ (Clearfil Universal Bond Quick) - and etching mode, either etch-and-rinse (ER) or self-etch (SE). Following adhesive application, composite was placed in two increments and light cured. The specimens were stored in distilled water at 37°C for 24 h. The µTBS test was performed using a universal testing machine. Failure mode was assessed using a light microscope. The data were statistically analyzed using three-way ANOVA followed by Scheffe's test (p < 0.05). The resin-dentin interface was observed using scanning electron microscopy.
Results: Significantly lower bond strength was observed when the universal adhesives were bonded to contaminated dentin in SE mode (p < 0.05). In contrast, the µTBS of the universal adhesives in ER mode was not affected by contamination (p > 0.05). The µTBS of CBQ to contaminated dentin was significantly lower than that of the other adhesives. Observation of the resin-dentin interface revealed limited resin penetration when the universal adhesive was applied in SE mode on contaminated dentin.
Conclusion: Contaminating the dentin with a hemostatic agent significantly reduced the µTBS of the universal adhesives in SE mode. However, this adverse effect was not found when the universal adhesives were used in ER mode.
期刊介绍:
ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications.
The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.