Complete Endovascular Reconstruction of the Canine Ascending Aorta, Aortic Arch, and Supra-Aortic Vessels by Implanting a New Unibody Outer Double-Branched Stent-Graft.
{"title":"Complete Endovascular Reconstruction of the Canine Ascending Aorta, Aortic Arch, and Supra-Aortic Vessels by Implanting a New Unibody Outer Double-Branched Stent-Graft.","authors":"Weixiao Li, Qiang Li, Jun Li, Mingzhe Cui, Rutao Xu, Shuiting Zhai, Tianxiao Li, Jiangbo Chen, Wenli Zhao","doi":"10.1177/15266028221139194","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We evaluated the feasibility and safety of using a new unibody outer double-branched stent-graft system to reconstruct the canine ascending aorta, aortic arch, and supra-aortic vessels.</p><p><strong>Materials and methods: </strong>The outer-branched stent-graft was a unibody design. The branched stent-graft consisted of a main stent-graft and 2 branches. The introducer system included a tri-channel catheter, 2 detachable sleeves, a front fixing device, a constraining wire, and a curved outer sheath. The branched stent-graft was loaded into the introducer system. Ten adult mongrel dogs underwent general anesthesia, and the branched stent-grafts were deployed into the canine ascending aorta, aortic arch, and supra-aortic vessels by the introducer system. All animals were followed up for 3 months. At the end of the follow-up period, computed tomographic angiography (CTA) was performed to observe the patency of the branched stent-grafts.</p><p><strong>Results: </strong>The mean operation time was 142.7±13.7 minutes. The mean fluoroscopy time was 20.73±2.22 minutes. The mean dosage of contrast agent was 95.9±8.7 mL. During the operation, the tri-channel catheters successfully paralleled the wires in the aorta. All 10 branched stent-grafts were successfully implanted into the canine ascending aorta and aortic arch. There were no symptoms of cerebral embolization and no incision infection during the follow-up period. Computed tomographic angiography and specimens showed that the branched stent-grafts and native vessels were patent, the inner surfaces of the branched stent-grafts were covered by neointima, and there was no retrograde aortic dissection in the ascending aorta.</p><p><strong>Conclusions: </strong>This animal research demonstrated that the unibody outer double-branched stent-graft system could be applied to reconstruct the canine ascending aorta, aortic arch, and supra-aortic vessels.</p><p><strong>Clinical impact: </strong>Thoracic endovascular aortic repair has been the main treatment method for aortic aneurysms or dissections involving the descending thoracic aorta. However, the aortic arch and ascending aorta remain the last segments of the aorta without a validated and routinely used endovascular option. In this research, we designed a new unibody outer branched stent-graft system to reconstruct the distal ascending aorta, aortic arch and supra-aortic vessels. The unibody outer branched stent-graft system could be applied to treat aortic pathologies which involve the middle and distal proximal ascending aorta, aortic arch and proximal descending aorta.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15266028221139194","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/11/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: We evaluated the feasibility and safety of using a new unibody outer double-branched stent-graft system to reconstruct the canine ascending aorta, aortic arch, and supra-aortic vessels.
Materials and methods: The outer-branched stent-graft was a unibody design. The branched stent-graft consisted of a main stent-graft and 2 branches. The introducer system included a tri-channel catheter, 2 detachable sleeves, a front fixing device, a constraining wire, and a curved outer sheath. The branched stent-graft was loaded into the introducer system. Ten adult mongrel dogs underwent general anesthesia, and the branched stent-grafts were deployed into the canine ascending aorta, aortic arch, and supra-aortic vessels by the introducer system. All animals were followed up for 3 months. At the end of the follow-up period, computed tomographic angiography (CTA) was performed to observe the patency of the branched stent-grafts.
Results: The mean operation time was 142.7±13.7 minutes. The mean fluoroscopy time was 20.73±2.22 minutes. The mean dosage of contrast agent was 95.9±8.7 mL. During the operation, the tri-channel catheters successfully paralleled the wires in the aorta. All 10 branched stent-grafts were successfully implanted into the canine ascending aorta and aortic arch. There were no symptoms of cerebral embolization and no incision infection during the follow-up period. Computed tomographic angiography and specimens showed that the branched stent-grafts and native vessels were patent, the inner surfaces of the branched stent-grafts were covered by neointima, and there was no retrograde aortic dissection in the ascending aorta.
Conclusions: This animal research demonstrated that the unibody outer double-branched stent-graft system could be applied to reconstruct the canine ascending aorta, aortic arch, and supra-aortic vessels.
Clinical impact: Thoracic endovascular aortic repair has been the main treatment method for aortic aneurysms or dissections involving the descending thoracic aorta. However, the aortic arch and ascending aorta remain the last segments of the aorta without a validated and routinely used endovascular option. In this research, we designed a new unibody outer branched stent-graft system to reconstruct the distal ascending aorta, aortic arch and supra-aortic vessels. The unibody outer branched stent-graft system could be applied to treat aortic pathologies which involve the middle and distal proximal ascending aorta, aortic arch and proximal descending aorta.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.