Psychiatric Disorders and Genotoxicity Following Primary Metal on Polyethylene Total Hip Arthroplasty and Their Correlation to Cobalt/Chromium Levels.

IF 2.2 Q2 HEALTH CARE SCIENCES & SERVICES Drug, Healthcare and Patient Safety Pub Date : 2022-07-18 eCollection Date: 2022-01-01 DOI:10.2147/DHPS.S360643
Omaima I Abdel Hamid, Mohamed E Attia, Jon M Hirshon, Mohamed El-Shinawi, Moustafa El-Hussaini, Maged El-Setouhy
{"title":"Psychiatric Disorders and Genotoxicity Following Primary Metal on Polyethylene Total Hip Arthroplasty and Their Correlation to Cobalt/Chromium Levels.","authors":"Omaima I Abdel Hamid, Mohamed E Attia, Jon M Hirshon, Mohamed El-Shinawi, Moustafa El-Hussaini, Maged El-Setouhy","doi":"10.2147/DHPS.S360643","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Hip arthroplasty (HA) using implantable metal components is among the commonest orthopedic interventions. However, it can be followed by several complications following corrosion and the release of metal ions. Several studies proved that damaged genomic DNA may contribute to the pathophysiology of mental disorders.</p><p><strong>Aim: </strong>The current work aims to evaluate the psychiatric disorders in metal on polyethylene hip arthroplasty (MOP-HA) patients and its correlation to cobalt/chromium (Co/Cr) levels and genotoxicity.</p><p><strong>Methods: </strong>The work was a longitudinal follow-up study including 34 adults with unilateral primary MOP-HA meeting the inclusion and exclusion criteria. Preoperatively, 6, 12-months-postoperatively, patients were examined for cognitive impairment using mini-mental-state-examination (MMSE), depression using major-depressive-inventory (MDI), and blood samples were collected for estimation of Co/Cr, detection of genotoxicity by single-cell-gel-electrophoresis (comet assay) and serum 8-hydroxy-2'-deoxyguanosine (8-OHdG).</p><p><strong>Results: </strong>Cognitive impairment was reported in 18.5% and 14.8% at 6-months, and 12-months postoperative, respectively. Depressive disorder was recorded in 22.2% at 6-months and 14.8% at 12-months postoperative. The marginal homogeneity tests proved a non-significant difference. There was a non-significant difference in preoperative, 6-months, 12-months postoperative MMSE, and MDI scores. There were significantly increased Co/Cr levels at 6-months postoperative. The levels decreased at 12-months postoperative, however, still significantly higher than preoperative values. There was a significant increase in serum 8-OHdG and the levels were positively correlated to cobalt levels at both 6 and 12-months-postoperative. There was a non-significant difference among preoperative, 6-months, and 12-months postoperative comet assay measurements.</p><p><strong>Conclusion: </strong>From previous findings, we can conclude that will-functioning MOP hip arthroplasty can induce increased ion levels and positively correlated increase in biochemical markers of genotoxicity (8-OHdG).</p>","PeriodicalId":11377,"journal":{"name":"Drug, Healthcare and Patient Safety","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2022-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/74/2f/dhps-14-97.PMC9308046.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug, Healthcare and Patient Safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/DHPS.S360643","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Hip arthroplasty (HA) using implantable metal components is among the commonest orthopedic interventions. However, it can be followed by several complications following corrosion and the release of metal ions. Several studies proved that damaged genomic DNA may contribute to the pathophysiology of mental disorders.

Aim: The current work aims to evaluate the psychiatric disorders in metal on polyethylene hip arthroplasty (MOP-HA) patients and its correlation to cobalt/chromium (Co/Cr) levels and genotoxicity.

Methods: The work was a longitudinal follow-up study including 34 adults with unilateral primary MOP-HA meeting the inclusion and exclusion criteria. Preoperatively, 6, 12-months-postoperatively, patients were examined for cognitive impairment using mini-mental-state-examination (MMSE), depression using major-depressive-inventory (MDI), and blood samples were collected for estimation of Co/Cr, detection of genotoxicity by single-cell-gel-electrophoresis (comet assay) and serum 8-hydroxy-2'-deoxyguanosine (8-OHdG).

Results: Cognitive impairment was reported in 18.5% and 14.8% at 6-months, and 12-months postoperative, respectively. Depressive disorder was recorded in 22.2% at 6-months and 14.8% at 12-months postoperative. The marginal homogeneity tests proved a non-significant difference. There was a non-significant difference in preoperative, 6-months, 12-months postoperative MMSE, and MDI scores. There were significantly increased Co/Cr levels at 6-months postoperative. The levels decreased at 12-months postoperative, however, still significantly higher than preoperative values. There was a significant increase in serum 8-OHdG and the levels were positively correlated to cobalt levels at both 6 and 12-months-postoperative. There was a non-significant difference among preoperative, 6-months, and 12-months postoperative comet assay measurements.

Conclusion: From previous findings, we can conclude that will-functioning MOP hip arthroplasty can induce increased ion levels and positively correlated increase in biochemical markers of genotoxicity (8-OHdG).

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
聚乙烯原生金属全髋关节置换术后的精神障碍和遗传毒性及其与钴/铬水平的相关性。
导言:使用植入式金属组件进行髋关节置换术(HA)是最常见的矫形手术之一。然而,随着金属离子的腐蚀和释放,可能会出现多种并发症。几项研究证明,基因组DNA受损可能会导致精神障碍的病理生理学。目的:目前的研究旨在评估聚乙烯金属髋关节置换术(MOP-HA)患者的精神障碍及其与钴/铬(Co/Cr)水平和遗传毒性的相关性:该研究是一项纵向随访研究,包括 34 名符合纳入和排除标准的单侧原发性 MOP-HA 患者。在术前、术后 6 个月和 12 个月,使用迷你精神状态检查(MMSE)对患者进行认知障碍检查,使用重度抑郁清单(MDI)对患者进行抑郁检查,并采集血液样本以估算钴/铬含量,使用单细胞凝胶电泳(彗星试验)和血清 8-羟基-2'-脱氧鸟苷(8-OHdG)检测遗传毒性:术后 6 个月和 12 个月分别有 18.5%和 14.8%的患者出现认知障碍。在术后 6 个月和 12 个月,分别有 22.2% 和 14.8% 的患者出现抑郁障碍。边际同质性检验证明差异不显著。术前、术后 6 个月、术后 12 个月的 MMSE 和 MDI 评分差异不显著。术后 6 个月,Co/Cr 水平明显升高。术后 12 个月,Co/Cr 水平有所下降,但仍明显高于术前值。术后 6 个月和 12 个月时,血清 8-OHdG 均明显增加,且与钴水平呈正相关。术前、术后 6 个月和术后 12 个月的彗星测定结果差异不明显:根据之前的研究结果,我们可以得出结论,功能性澳门葡京娱乐网址髋关节置换术会导致离子水平升高,并与遗传毒性生化指标(8-OHdG)的升高呈正相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Drug, Healthcare and Patient Safety
Drug, Healthcare and Patient Safety HEALTH CARE SCIENCES & SERVICES-
CiteScore
4.10
自引率
0.00%
发文量
24
审稿时长
16 weeks
期刊最新文献
The Impact of Sacubitril/Valsartan on Heart Failure Patient with Reduced Left Ventricular Ejection Fraction: Single Center Retrospective Study in Saudi Arabia. Adverse Events Following Immunization with Novel Oral Polio Vaccine Type 2, and the Experience and Challenges of Reporting in Sierra Leone [Response to Letter]. Baloxavir Resistance Markers in Influenza A and B Viruses in the Americas. Adverse Events Following Immunization with Novel Oral Polio Vaccine Type 2, and the Experience and Challenges of Reporting in Sierra Leone [Letter]. Adverse Drug Reactions Related with Antibiotic Medicines in Malawi: A Retrospective Analysis of Prevalence and Associated Factors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1