Performance of a Convolutional Neural Network- Based Artificial Intelligence Algorithm for Automatic Cephalometric Landmark Detection.

IF 0.8 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Turkish Journal of Orthodontics Pub Date : 2022-06-01 DOI:10.5152/TurkJOrthod.2022.22026
Mehmet Uğurlu
{"title":"Performance of a Convolutional Neural Network- Based Artificial Intelligence Algorithm for Automatic Cephalometric Landmark Detection.","authors":"Mehmet Uğurlu","doi":"10.5152/TurkJOrthod.2022.22026","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of this study is to develop an artificial intelligence model to detect cephalometric landmark automatically en- abling the automatic analysis of cephalometric radiographs which have a very important place in dental practice and is used routinely in the diagnosis and treatment of dental and skeletal disorders.</p><p><strong>Methods: </strong>In this study, 1620 lateral cephalograms were obtained and 21 landmarks were included. The coordinates of all landmarks in the 1620 films were obtained to establish a labeled data set: 1360 were used as a training set, 140 as a validation set, and 180 as a testing set. A convolutional neural network-based artificial intelligence algorithm for automatic cephalometric landmark detection was developed. Mean radial error and success detection rate within the range of 2 mm, 2.5 mm, 3 mm, and 4 mm were used to eval- uate the performance of the model.</p><p><strong>Results: </strong>Presented artificial intelligence system (CranioCatch, Eskişehir, Turkey) could detect 21 anatomic landmarks in a lateral ceph- alometric radiograph. The highest success detection rate scores of 2 mm, 2.5 mm, 3 mm, and 4 mm were obtained from the sella point as 98.3, 99.4, 99.4, and 99.4, respectively. The mean radial error ± standard deviation value of the sella point was found as 0.616 ± 0.43. The lowest success detection rate scores of 2 mm, 2.5 mm, 3 mm, and 4 mm were obtained from the Gonion point as 48.3, 62.8, 73.9, and 87.2, respectively. The mean radial error ± standard deviation value of Gonion point was found as 8.304 ± 2.98.</p><p><strong>Conclusion: </strong>Although the success of the automatic landmark detection using the developed artificial intelligence model was not in- sufficient for clinical use, artificial intelligence-based cephalometric analysis systems seem promising to cephalometric analysis which provides a basis for diagnosis, treatment planning, and following-up in clinical orthodontics practice.</p>","PeriodicalId":37013,"journal":{"name":"Turkish Journal of Orthodontics","volume":"35 2","pages":"94-100"},"PeriodicalIF":0.8000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9450082/pdf/tjo-35-2-94.pdf","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5152/TurkJOrthod.2022.22026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 3

Abstract

Objective: The aim of this study is to develop an artificial intelligence model to detect cephalometric landmark automatically en- abling the automatic analysis of cephalometric radiographs which have a very important place in dental practice and is used routinely in the diagnosis and treatment of dental and skeletal disorders.

Methods: In this study, 1620 lateral cephalograms were obtained and 21 landmarks were included. The coordinates of all landmarks in the 1620 films were obtained to establish a labeled data set: 1360 were used as a training set, 140 as a validation set, and 180 as a testing set. A convolutional neural network-based artificial intelligence algorithm for automatic cephalometric landmark detection was developed. Mean radial error and success detection rate within the range of 2 mm, 2.5 mm, 3 mm, and 4 mm were used to eval- uate the performance of the model.

Results: Presented artificial intelligence system (CranioCatch, Eskişehir, Turkey) could detect 21 anatomic landmarks in a lateral ceph- alometric radiograph. The highest success detection rate scores of 2 mm, 2.5 mm, 3 mm, and 4 mm were obtained from the sella point as 98.3, 99.4, 99.4, and 99.4, respectively. The mean radial error ± standard deviation value of the sella point was found as 0.616 ± 0.43. The lowest success detection rate scores of 2 mm, 2.5 mm, 3 mm, and 4 mm were obtained from the Gonion point as 48.3, 62.8, 73.9, and 87.2, respectively. The mean radial error ± standard deviation value of Gonion point was found as 8.304 ± 2.98.

Conclusion: Although the success of the automatic landmark detection using the developed artificial intelligence model was not in- sufficient for clinical use, artificial intelligence-based cephalometric analysis systems seem promising to cephalometric analysis which provides a basis for diagnosis, treatment planning, and following-up in clinical orthodontics practice.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种基于卷积神经网络的人工智能算法的自动头侧标记检测性能。
目的:本研究的目的是开发一种人工智能模型来自动检测头影测量标志,从而实现头影测量X线片的自动分析。头影测量x线片在牙科实践中具有非常重要的地位,并在牙科和骨骼疾病的诊断和治疗中常规使用。方法:本研究共获得1620张侧位头影,包括21个标志。获得1620张胶片中所有地标的坐标,以建立标记数据集:1360张用作训练集,140张用作验证集,180张用作测试集。开发了一种基于卷积神经网络的人工智能算法,用于自动头影测量界标检测。使用2 mm、2.5 mm、3 mm和4 mm范围内的平均径向误差和成功检测率来评估模型的性能。结果:所提出的人工智能系统(CranioCatch,Eskişehir,土耳其)可以在侧位ceph-alometric射线照片中检测到21个解剖标志。鞍点2 mm、2.5 mm、3 mm和4 mm的最高成功检测率得分分别为98.3、99.4、99.4和99.4。鞍点的平均径向误差±标准偏差值为0.616±0.43。从Gonion点获得的2 mm、2.5 mm、3 mm和4 mm的最低成功检测率得分分别为48.3、62.8、73.9和87.2。Gonion点的平均径向误差±标准偏差值为8.304±2.98,治疗计划和临床正畸实践的跟进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Turkish Journal of Orthodontics
Turkish Journal of Orthodontics Dentistry-Orthodontics
CiteScore
2.10
自引率
9.10%
发文量
34
期刊最新文献
Accuracy of 3D Printer Technologies Using Digital Dental Models. Comparing the Impact of Titanium and Stainless Steel Retainers on Lower Incisor Stability, Periodontal Health, and Retainer Survival: A Preliminary Study. Comparison of the Effects of Fixed and Removable Functional Orthodontic Treatment on the Mandibular Trabecular Bone in Fractal Analysis. Effects of Emotional States on Reproducibilities of Rest Position, Social and Spontaneous Smiles, and Speech. Erratum.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1