Design of a New "U"-shaped Staple and Its Clinical Application in Postoperative Ankle Valgus of Congenital Pseudarthrosis of the Tibia in Children.

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2022-09-01 Epub Date: 2022-07-20 DOI:10.1111/os.13381
Xiongke Hu, Anping Li, Kun Liu, Jiangyan Wu, Haibo Mei
{"title":"Design of a New \"U\"-shaped Staple and Its Clinical Application in Postoperative Ankle Valgus of Congenital Pseudarthrosis of the Tibia in Children.","authors":"Xiongke Hu,&nbsp;Anping Li,&nbsp;Kun Liu,&nbsp;Jiangyan Wu,&nbsp;Haibo Mei","doi":"10.1111/os.13381","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>There has been a lack of suitable epiphysis blocking materials due to the characteristics of less tissue coverage and narrow epiphysis in children's distal tibial medial malleolus. Therefore, this study is to investigate the clinical efficacy and safety of a new \"U\"-shaped staple in the treatment of postoperative ankle valgus of congenital pseudarthrosis of the tibia (CPT).</p><p><strong>Method: </strong>According to the inclusion and exclusion criteria, 33 patients with postoperative ankle valgus of CPT were treated with new \"U\"-shaped staples from May 2013 to September 2019. The deformity of ankle valgus was gradually corrected by implanting a new \"U\"-shaped staple on the medial side of the distal tibia. Clinical indexes such as the operation time, intraoperative bleeding and hospital stay were observed. Tibiotalar angle was selected as the evaluation index of ankle valgus. American Orthopedic Foot & Ankle Society (AOFAS) scale was used for clinical evaluation of ankle function. The tibiotalar angle, deformity correction rate and complications were evaluated by preoperative, postoperative and last follow-up imaging data. Student's t-test was used for statistical analysis.</p><p><strong>Results: </strong>Thirty-three patients, including 12 males and 21 females were included. All the patients were followed up for at least 14 months, with an average of 35 months. The average operation time was 23 (15-40) min, the average amount of intraoperative bleeding was 7.5 (4-10) mL, and the average hospital stay was 4.2 (3-6) days. The intraoperative tibiotalar angles of all patients were 74.2° ± 4.6°, the tibiotalar angle were 86.8° ± 4.9° when internal fixation was removed, and the tibiotalar angles at the last follow-up were 84.3° ± 5.9°. The average orthopedic rate was 0.68° per month. No patients suffered from serious complications such as screw prolapse, osteomyelitis, wound infection, etc. Postoperative wound pain complications occurred in two patients, which were relieved after conservative treatment. The AOFAS score improved from 46.2 ± 9.4 before the operation to 74.6 ± 5.7 at the last follow-up (P < 0.01). The ankle movement was good without joint stiffness. There was no epiphyseal plate injury after the removal of internal fixation.</p><p><strong>Conclusion: </strong>The new \"U\"-shaped staple is characterized by simple implantation, low notch, lower risk of fixation failure and close fitting with cortical bone. It is a safe and effective internal fixation system for the treatment of ankle valgus in children.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":" ","pages":"1981-1988"},"PeriodicalIF":16.4000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9483067/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/os.13381","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/7/20 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: There has been a lack of suitable epiphysis blocking materials due to the characteristics of less tissue coverage and narrow epiphysis in children's distal tibial medial malleolus. Therefore, this study is to investigate the clinical efficacy and safety of a new "U"-shaped staple in the treatment of postoperative ankle valgus of congenital pseudarthrosis of the tibia (CPT).

Method: According to the inclusion and exclusion criteria, 33 patients with postoperative ankle valgus of CPT were treated with new "U"-shaped staples from May 2013 to September 2019. The deformity of ankle valgus was gradually corrected by implanting a new "U"-shaped staple on the medial side of the distal tibia. Clinical indexes such as the operation time, intraoperative bleeding and hospital stay were observed. Tibiotalar angle was selected as the evaluation index of ankle valgus. American Orthopedic Foot & Ankle Society (AOFAS) scale was used for clinical evaluation of ankle function. The tibiotalar angle, deformity correction rate and complications were evaluated by preoperative, postoperative and last follow-up imaging data. Student's t-test was used for statistical analysis.

Results: Thirty-three patients, including 12 males and 21 females were included. All the patients were followed up for at least 14 months, with an average of 35 months. The average operation time was 23 (15-40) min, the average amount of intraoperative bleeding was 7.5 (4-10) mL, and the average hospital stay was 4.2 (3-6) days. The intraoperative tibiotalar angles of all patients were 74.2° ± 4.6°, the tibiotalar angle were 86.8° ± 4.9° when internal fixation was removed, and the tibiotalar angles at the last follow-up were 84.3° ± 5.9°. The average orthopedic rate was 0.68° per month. No patients suffered from serious complications such as screw prolapse, osteomyelitis, wound infection, etc. Postoperative wound pain complications occurred in two patients, which were relieved after conservative treatment. The AOFAS score improved from 46.2 ± 9.4 before the operation to 74.6 ± 5.7 at the last follow-up (P < 0.01). The ankle movement was good without joint stiffness. There was no epiphyseal plate injury after the removal of internal fixation.

Conclusion: The new "U"-shaped staple is characterized by simple implantation, low notch, lower risk of fixation failure and close fitting with cortical bone. It is a safe and effective internal fixation system for the treatment of ankle valgus in children.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型“U”型钉的设计及其在儿童先天性胫骨假关节术后踝关节外翻中的临床应用。
目的:儿童胫骨内踝远端骨骺覆盖面积小,骨骺狭窄,一直缺乏合适的骨骺封堵材料。因此,本研究旨在探讨一种新型“U”型钉治疗先天性胫骨假关节(CPT)术后踝关节外翻的临床疗效和安全性。方法:2013年5月至2019年9月,对33例CPT术后踝关节外翻患者采用新型“U”型钉治疗。通过在胫骨远端内侧植入新的“U”形钉,逐渐矫正踝关节外翻畸形。观察手术时间、术中出血量、住院时间等临床指标。选择胫距角作为踝关节外翻的评价指标。采用美国骨科足踝学会(AOFAS)量表对踝关节功能进行临床评价。通过术前、术后及最后随访影像资料评估胫距角、畸形矫正率及并发症。采用学生t检验进行统计分析。结果:共纳入33例患者,其中男性12例,女性21例。所有患者均随访至少14个月,平均35个月。平均手术时间23 (15 ~ 40)min,平均术中出血量7.5 (4 ~ 10)mL,平均住院时间4.2 (3 ~ 6)d。术中所有患者的胫距角为74.2°±4.6°,拆除内固定时胫距角为86.8°±4.9°,末次随访时胫距角为84.3°±5.9°。平均矫形率为每月0.68°。未发生螺钉脱垂、骨髓炎、伤口感染等严重并发症。术后2例出现创面疼痛并发症,经保守治疗后缓解。术后AOFAS评分由术前的46.2±9.4分提高至末次随访时的74.6±5.7分(P)。结论:新型“U”型钉具有植入简单、切口小、固定失败风险低、与皮质骨贴合紧密等特点。它是治疗儿童踝关节外翻安全有效的内固定系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Laryngeal Cancer With Lung Metastases Showing Long-Term Complete Response and Delayed Immune-Related Adverse Event After Nivolumab Discontinuation. Lung Adenocarcinoma Metastasis to the Vocal Cord. Effects of Hyaluronic Acid/Collagen Resorbable Gel Use in Endoscopic Dacryocystorhinostomy. Thyroglossal duct cyst with hoarseness as the sole symptom and an intralaryngeal extension masquerading as a laryngeal mass: Clinical experience and literature review. Fourth branchial cleft anomaly in a 7-month-old infant: A case report and literature review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1