Deborah K Glencross, Leanne Swart, Melanie Pretorius, Denise Lawrie
{"title":"Evaluation of fixed-panel, multicolour ClearLLab 10C at an academic flow cytometry laboratory in Johannesburg, South Africa.","authors":"Deborah K Glencross, Leanne Swart, Melanie Pretorius, Denise Lawrie","doi":"10.4102/ajlm.v11i1.1458","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Flow cytometric immunophenotyping is well established for the diagnosis of haematological neoplasms. New commercially available systems offer fixed, pre-aliquoted multi-parameter analysis to simplify sample preparation and standardise data analysis.</p><p><strong>Objective: </strong>The Beckman Coulter (BC) ClearLLab™ 10C (4-tube) system was evaluated against an existing laboratory developed test (LDT).</p><p><strong>Methods: </strong>Peripheral blood and bone marrow aspirates (<i>n</i> = 101), tested between August 2019 and November 2019 at an academic pathology laboratory in Johannesburg, South Africa, were analysed. Following daily instrument quality control, samples were prepared for LDT (using > 20 2-4-colour in-house panels and an extensive liquid monoclonal reagent repertoire) or ClearLLab 10C, and respectively analysed using in-house protocols on a Becton Dickinson FACSCalibur, or manufacturer-directed protocols on a BC Navios. Becton Dickinson Paint-a-Gate or BC Kaluza C software facilitated data interpretation. Diagnostic accuracy (concordance) was established by calculating sensitivity and specificity outcomes.</p><p><strong>Results: </strong>Excellent agreement (clinical diagnostic concordance) with 100% specificity and sensitivity was established between LDT and ClearLLab 10C in 67 patients with a haematological neoplasm and 34 participants with no haematological disease. Similar acceptable diagnostic concordance (97%) was noted when comparing ClearLLab 10C to clinicopathological outcomes. Additionally, the ClearLLab 10C panels, analysed with Kaluza C software, enabled simultaneous discrimination of disease and concurrent background myeloid and lymphoid haematological populations, including assessing stages of maturation or sub-populations.</p><p><strong>Conclusion: </strong>ClearLLab 10C panels provide excellent agreement to existing LDTs and may reliably be used for immunophenotyping of haematological neoplasms, simplifying and standardising sample preparation and data acquisition.</p>","PeriodicalId":45412,"journal":{"name":"African Journal of Laboratory Medicine","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2022-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9350555/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Journal of Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4102/ajlm.v11i1.1458","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Flow cytometric immunophenotyping is well established for the diagnosis of haematological neoplasms. New commercially available systems offer fixed, pre-aliquoted multi-parameter analysis to simplify sample preparation and standardise data analysis.
Objective: The Beckman Coulter (BC) ClearLLab™ 10C (4-tube) system was evaluated against an existing laboratory developed test (LDT).
Methods: Peripheral blood and bone marrow aspirates (n = 101), tested between August 2019 and November 2019 at an academic pathology laboratory in Johannesburg, South Africa, were analysed. Following daily instrument quality control, samples were prepared for LDT (using > 20 2-4-colour in-house panels and an extensive liquid monoclonal reagent repertoire) or ClearLLab 10C, and respectively analysed using in-house protocols on a Becton Dickinson FACSCalibur, or manufacturer-directed protocols on a BC Navios. Becton Dickinson Paint-a-Gate or BC Kaluza C software facilitated data interpretation. Diagnostic accuracy (concordance) was established by calculating sensitivity and specificity outcomes.
Results: Excellent agreement (clinical diagnostic concordance) with 100% specificity and sensitivity was established between LDT and ClearLLab 10C in 67 patients with a haematological neoplasm and 34 participants with no haematological disease. Similar acceptable diagnostic concordance (97%) was noted when comparing ClearLLab 10C to clinicopathological outcomes. Additionally, the ClearLLab 10C panels, analysed with Kaluza C software, enabled simultaneous discrimination of disease and concurrent background myeloid and lymphoid haematological populations, including assessing stages of maturation or sub-populations.
Conclusion: ClearLLab 10C panels provide excellent agreement to existing LDTs and may reliably be used for immunophenotyping of haematological neoplasms, simplifying and standardising sample preparation and data acquisition.
期刊介绍:
The African Journal of Laboratory Medicine, the official journal of ASLM, focuses on the role of the laboratory and its professionals in the clinical and public healthcare sectors,and is specifically based on an African frame of reference. Emphasis is on all aspects that promote and contribute to the laboratory medicine practices of Africa. This includes, amongst others: laboratories, biomedical scientists and clinicians, medical community, public health officials and policy makers, laboratory systems and policies (translation of laboratory knowledge, practices and technologies in clinical care), interfaces of laboratory with medical science, laboratory-based epidemiology, laboratory investigations, evidence-based effectiveness in real world (actual) settings.