Performance of different body weights in the Cockcroft-Gault equation in critically ill patients with and without augmented renal clearance: A multicenter cohort.
Michaelia D Cucci, Anthony T Gerlach, Caroline Mangira, Claire V Murphy, Jason A Roberts, Andrew A Udy, Thomas C Dowling, Chanda L Mullen
{"title":"Performance of different body weights in the Cockcroft-Gault equation in critically ill patients with and without augmented renal clearance: A multicenter cohort.","authors":"Michaelia D Cucci, Anthony T Gerlach, Caroline Mangira, Claire V Murphy, Jason A Roberts, Andrew A Udy, Thomas C Dowling, Chanda L Mullen","doi":"10.1002/phar.2743","DOIUrl":null,"url":null,"abstract":"<p><strong>Study objective: </strong>The primary objective was to evaluate the performance of the Cockcroft-Gault (CG) equation with different body weights (BWs) compared to a measured creatinine clearance (mCrCl) in an intensive care unit (ICU) population with and without augmented renal clearance (ARC).</p><p><strong>Design: </strong>Multicenter, retrospective cohort.</p><p><strong>Setting: </strong>Two ICUs in the United States and four ICUs from a previous international observational analysis.</p><p><strong>Patients: </strong>Adult ICU patients admitted from January 1, 2010 to July 30, 2020 with at least one mCrCl collected within the initial 10 days of hospitalization were eligible for inclusion.</p><p><strong>Measurements and main results: </strong>The primary outcome was the performance of the CG equation in ARC (mCrCl≥130 ml/min/1.73 m<sup>2</sup> ) and non-ARC (mCrCl<130 ml/min/1.73 m<sup>2</sup> ) patients. Correlation was analyzed by Pearson's correlation coefficient, bias by mean difference, and accuracy by the percentage of patients within 30% of the mCrCl. A total of 383 patients were included, which provided 1708 mCrCl values. The majority were male (n = 239, 62%), median age of 55 years [IQR 40-65] with a surgical diagnosis (n = 239, 77%). ARC was identified in 229 (60%) patients. The ARC group had lower Scr values (0.6 [0.5-0.7] vs. 0.7 [0.6-0.9] mg/dl, p < 0.001) and higher mCrCl (172.8 (SD 39.1) vs. 89.9 mL/min/1.73 m<sup>2</sup> (SD 25.4), p < 0.001) compared with the non-ARC group, respectively. Among non-ARC patients there was a moderate correlation (r = 0.33-0.39), moderate accuracy (range 48-58%), and low bias (range of -12.9 to 17.1) among the different BW estimations with the adjusted BW having the better performance. Among ARC patients there was low correlation (r = 0.24-0.28), low to moderate accuracy (range 38-70%), and high bias (range of -58.5 to -21.6).</p><p><strong>Conclusions: </strong>The CG-adjusted BW had the best performance in the non-ARC patients, while CG performed poorly with any BW in ARC patients. Although the CG equation remains the standard equation for estimating CrCl in the ICU setting, a new, validated equation is needed for patients with ARC.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":" ","pages":"1131-1138"},"PeriodicalIF":4.7000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10947228/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/phar.2743","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/11/24 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
Study objective: The primary objective was to evaluate the performance of the Cockcroft-Gault (CG) equation with different body weights (BWs) compared to a measured creatinine clearance (mCrCl) in an intensive care unit (ICU) population with and without augmented renal clearance (ARC).
Design: Multicenter, retrospective cohort.
Setting: Two ICUs in the United States and four ICUs from a previous international observational analysis.
Patients: Adult ICU patients admitted from January 1, 2010 to July 30, 2020 with at least one mCrCl collected within the initial 10 days of hospitalization were eligible for inclusion.
Measurements and main results: The primary outcome was the performance of the CG equation in ARC (mCrCl≥130 ml/min/1.73 m2 ) and non-ARC (mCrCl<130 ml/min/1.73 m2 ) patients. Correlation was analyzed by Pearson's correlation coefficient, bias by mean difference, and accuracy by the percentage of patients within 30% of the mCrCl. A total of 383 patients were included, which provided 1708 mCrCl values. The majority were male (n = 239, 62%), median age of 55 years [IQR 40-65] with a surgical diagnosis (n = 239, 77%). ARC was identified in 229 (60%) patients. The ARC group had lower Scr values (0.6 [0.5-0.7] vs. 0.7 [0.6-0.9] mg/dl, p < 0.001) and higher mCrCl (172.8 (SD 39.1) vs. 89.9 mL/min/1.73 m2 (SD 25.4), p < 0.001) compared with the non-ARC group, respectively. Among non-ARC patients there was a moderate correlation (r = 0.33-0.39), moderate accuracy (range 48-58%), and low bias (range of -12.9 to 17.1) among the different BW estimations with the adjusted BW having the better performance. Among ARC patients there was low correlation (r = 0.24-0.28), low to moderate accuracy (range 38-70%), and high bias (range of -58.5 to -21.6).
Conclusions: The CG-adjusted BW had the best performance in the non-ARC patients, while CG performed poorly with any BW in ARC patients. Although the CG equation remains the standard equation for estimating CrCl in the ICU setting, a new, validated equation is needed for patients with ARC.
期刊介绍:
ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications.
The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.