Influence of the self-adhering strategy on microhardness, sorption, solubility, color stability, and cytotoxicity compared to bulk-fill and conventional resin composites.

IF 3.1 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Clinical Oral Investigations Pub Date : 2022-11-01 Epub Date: 2022-08-02 DOI:10.1007/s00784-022-04624-5
Natália Gomes de Oliveira, Luís Felipe Espíndola-Castro, Julliana Carvalho Rocha, Amanda Pinheiro de Barros Albuquerque, Moacyr Jesus Barreto de Melo Rêgo, Gabriela Queiroz de Melo Monteiro, Marianne de Vasconcelos Carvalho
{"title":"Influence of the self-adhering strategy on microhardness, sorption, solubility, color stability, and cytotoxicity compared to bulk-fill and conventional resin composites.","authors":"Natália Gomes de Oliveira,&nbsp;Luís Felipe Espíndola-Castro,&nbsp;Julliana Carvalho Rocha,&nbsp;Amanda Pinheiro de Barros Albuquerque,&nbsp;Moacyr Jesus Barreto de Melo Rêgo,&nbsp;Gabriela Queiroz de Melo Monteiro,&nbsp;Marianne de Vasconcelos Carvalho","doi":"10.1007/s00784-022-04624-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To analyze and compare, in vitro, the microhardness, sorption, solubility, color stability, and cytotoxicity of three types of resin composites: self-adhesive (SARC) (Dyad Flow (DF)/Kerr), bulk-fill (Filtek Bulk Fill Flow (FBF)/3 M ESPE), and conventional (Filtek Z350XT Flow (Z350)/3 M ESPE).</p><p><strong>Materials and methods: </strong>Thirty cylindrical specimens were prepared using a split metal mold (15 mm × 1 mm), divided into 3 groups (n = 10) according to the material used. Vickers hardness (VH) was calculated from three indentations (300gf/15 s) per specimen. The sorption and solubility were measured according to the ISO 4049:2009 specification after storing in distilled water for 7 days. The color of each resin composite was measured using a portable digital spectrophotometer according to the CIELAB system. After a 7-day immersion in coffee, the color variation (∆E) was calculated. Following the ISO 10993:2012, the cytotoxicity in Vero cells was evaluated through the MTT assay. The results were analyzed using the Kruskal-Wallis test to compare the studied groups. The Wilcoxon test was used to compare the assessments in each studied group. For cytotoxicity analysis, the data were compared by the ANOVA test (α = 0.05).</p><p><strong>Results: </strong>DF showed the lowest VH (28.67), highest sorption (0.543 µg/mm<sup>3</sup>) and solubility (1.700 µg/mm<sup>3</sup>), and higher ∆E after 7 days of coffee immersion (p = 0.008). The resin composites studied were considered non-cytotoxic.</p><p><strong>Conclusions: </strong>The SARC presented inferior mechanical and physical-chemical properties than bulk-fill and conventional resin composites, with comparable cytotoxicity against Vero cells.</p><p><strong>Clinical relevance: </strong>The simplification of the clinical protocol of SARC can minimize the number of possible failures during the restorative technique. However, considering their inferior physical and mechanical properties, their coverage with materials of higher mechanical properties and physical-chemical stability should be considered.</p>","PeriodicalId":10461,"journal":{"name":"Clinical Oral Investigations","volume":" ","pages":"6663-6670"},"PeriodicalIF":3.1000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Investigations","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00784-022-04624-5","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/2 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

Abstract

Objectives: To analyze and compare, in vitro, the microhardness, sorption, solubility, color stability, and cytotoxicity of three types of resin composites: self-adhesive (SARC) (Dyad Flow (DF)/Kerr), bulk-fill (Filtek Bulk Fill Flow (FBF)/3 M ESPE), and conventional (Filtek Z350XT Flow (Z350)/3 M ESPE).

Materials and methods: Thirty cylindrical specimens were prepared using a split metal mold (15 mm × 1 mm), divided into 3 groups (n = 10) according to the material used. Vickers hardness (VH) was calculated from three indentations (300gf/15 s) per specimen. The sorption and solubility were measured according to the ISO 4049:2009 specification after storing in distilled water for 7 days. The color of each resin composite was measured using a portable digital spectrophotometer according to the CIELAB system. After a 7-day immersion in coffee, the color variation (∆E) was calculated. Following the ISO 10993:2012, the cytotoxicity in Vero cells was evaluated through the MTT assay. The results were analyzed using the Kruskal-Wallis test to compare the studied groups. The Wilcoxon test was used to compare the assessments in each studied group. For cytotoxicity analysis, the data were compared by the ANOVA test (α = 0.05).

Results: DF showed the lowest VH (28.67), highest sorption (0.543 µg/mm3) and solubility (1.700 µg/mm3), and higher ∆E after 7 days of coffee immersion (p = 0.008). The resin composites studied were considered non-cytotoxic.

Conclusions: The SARC presented inferior mechanical and physical-chemical properties than bulk-fill and conventional resin composites, with comparable cytotoxicity against Vero cells.

Clinical relevance: The simplification of the clinical protocol of SARC can minimize the number of possible failures during the restorative technique. However, considering their inferior physical and mechanical properties, their coverage with materials of higher mechanical properties and physical-chemical stability should be considered.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
与填充型和传统树脂复合材料相比,自粘策略对显微硬度、吸附、溶解度、颜色稳定性和细胞毒性的影响。
目的:分析比较自粘(SARC) (Dyad Flow (DF)/Kerr)、填充(Filtek Bulk Fill Flow (FBF)/ 3m ESPE)和常规(Filtek Z350XT Flow (Z350)/ 3m ESPE)三种树脂复合材料的显微硬度、吸附、溶解度、颜色稳定性和细胞毒性。材料与方法:采用金属分体式模具(15mm × 1mm)制备圆柱形试样30个,按所用材料分为3组(n = 10)。维氏硬度(VH)由每个试样的三个压痕(300gf/15 s)计算。在蒸馏水中存放7天后,按照ISO 4049:2009规范测量吸附性和溶解度。根据CIELAB系统,使用便携式数字分光光度计测量每种树脂复合材料的颜色。在咖啡中浸泡7天后,计算颜色变化(∆E)。根据ISO 10993:2012,通过MTT试验评估Vero细胞的细胞毒性。使用Kruskal-Wallis测试对结果进行分析,以比较研究组。采用Wilcoxon检验比较各研究组的评估结果。细胞毒性分析采用方差分析(ANOVA)进行比较(α = 0.05)。结果:DF在咖啡浸泡7天后VH最低(28.67),吸附性最高(0.543µg/mm3),溶解度最高(1.700µg/mm3),∆E较高(p = 0.008)。所研究的树脂复合材料被认为是非细胞毒性的。结论:SARC的力学和物理化学性能低于填充型和常规树脂复合材料,但对Vero细胞具有相当的细胞毒性。临床意义:SARC临床方案的简化可以最大限度地减少修复技术中可能失败的次数。然而,考虑到其较差的物理力学性能,应考虑其与更高力学性能和物理化学稳定性的材料的覆盖。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical Oral Investigations
Clinical Oral Investigations 医学-牙科与口腔外科
CiteScore
6.30
自引率
5.90%
发文量
484
审稿时长
3 months
期刊介绍: The journal Clinical Oral Investigations is a multidisciplinary, international forum for publication of research from all fields of oral medicine. The journal publishes original scientific articles and invited reviews which provide up-to-date results of basic and clinical studies in oral and maxillofacial science and medicine. The aim is to clarify the relevance of new results to modern practice, for an international readership. Coverage includes maxillofacial and oral surgery, prosthetics and restorative dentistry, operative dentistry, endodontics, periodontology, orthodontics, dental materials science, clinical trials, epidemiology, pedodontics, oral implant, preventive dentistiry, oral pathology, oral basic sciences and more.
期刊最新文献
Osseous free flap vs. Bridging plate mandibular reconstruction: a retrospective cohort study on perioperative complications of 335 patients. Effect of cigarette smoke on surface roughness and bacterial adhesion of orthodontic aligners: an in vitro investigation. Lymph node metastasis pattern in recurrent and ipsilateral second primary oral squamous cell carcinoma. Load-bearing capacity of knife-edged monolithic zirconia crowns: effect of thickness and fabrication method. The relationship between clinical severity of obstructive sleep apnea based on polysomnography and drug-induced sleep endoscopy with 3D, 2D, linear, and angular anatomical parameters of upper airway and craniofacial area in CBCTs of individuals with moderate or severe apnea: a cross-sectional study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1