Prakash Ajmera, Ramesh Pothineni, Kamal Kumar Chawla, Sai Sudhakar Mantravadi, Pankaj Jariwala, Vinod Vijan, Vikrant Vijan
{"title":"Twelve months clinical outcomes of ultrathin strut sirolimus-eluting stent in real-world Indian patients with coronary artery disease.","authors":"Prakash Ajmera, Ramesh Pothineni, Kamal Kumar Chawla, Sai Sudhakar Mantravadi, Pankaj Jariwala, Vinod Vijan, Vikrant Vijan","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Although the field of interventional cardiology has witnessed extraordinary progression, the search of an ideal coronary drug-eluting stent is still going on. Tetriflex (Sahajanand Medical Technologies Limited, Surat, India) is a latest generation biodegradable polymer-coated ultrathin (60 µm) sirolimus-eluting stent (SES) with unique Long Dual Z-link (LDZ) design. The present registry reports the 12 months clinical follow-up results of Tetriflex SES in unselected, real-world patients with coronary artery disease (CAD).</p><p><strong>Methods: </strong>This was an investigator-initiated, retrospective, multi-center, single-arm, observational registry conducted in India between March-2017 and March-2018. The registry included 1269 consecutive patients with CAD who underwent implantation of at least one Tetriflex SES. The primary outcome was considered as target lesion failure (TLF), which was a composite of cardiac death, target-vessel myocardial infarction (TV-MI) and clinically-driven target lesion revascularisation (CD-TLR) at 12 months follow-up. The safety outcome, at 12 months follow-up, was stent thrombosis.</p><p><strong>Results: </strong>Mean age of patients was 54.99±10.80 years. Among all, 36.6% patients had diabetes and 51.7% patients had multi-vessel disease. A total of 1515 lesions were treated with 1682 Tetriflex SES of which 73.2% lesions were complex B2/C type and 14.7% were totally occluded. At 12 months, the cumulative incidence of TLF was 5.75% comprising 0.8% cardiac death, 3.20% TV-MI and 1.72% CD-TLR. All the incidences of definite/probable stent thrombosis (n = 4, 0.32%) were reported within 30 days of the index procedure. Twelve-month cumulative incidence of TLF in diabetic subgroup was 7.10%.</p><p><strong>Conclusion: </strong>Twelve months clinical follow-up results of an ultrathin (60 µm), biodegradable polymer-coated Tetriflex SES, with unique LDZ-link, further clarify its safety and effectiveness in real-world, unselected Indian patients.</p>","PeriodicalId":7427,"journal":{"name":"American journal of cardiovascular disease","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2022-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9677186/pdf/ajcd0012-0262.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of cardiovascular disease","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Although the field of interventional cardiology has witnessed extraordinary progression, the search of an ideal coronary drug-eluting stent is still going on. Tetriflex (Sahajanand Medical Technologies Limited, Surat, India) is a latest generation biodegradable polymer-coated ultrathin (60 µm) sirolimus-eluting stent (SES) with unique Long Dual Z-link (LDZ) design. The present registry reports the 12 months clinical follow-up results of Tetriflex SES in unselected, real-world patients with coronary artery disease (CAD).
Methods: This was an investigator-initiated, retrospective, multi-center, single-arm, observational registry conducted in India between March-2017 and March-2018. The registry included 1269 consecutive patients with CAD who underwent implantation of at least one Tetriflex SES. The primary outcome was considered as target lesion failure (TLF), which was a composite of cardiac death, target-vessel myocardial infarction (TV-MI) and clinically-driven target lesion revascularisation (CD-TLR) at 12 months follow-up. The safety outcome, at 12 months follow-up, was stent thrombosis.
Results: Mean age of patients was 54.99±10.80 years. Among all, 36.6% patients had diabetes and 51.7% patients had multi-vessel disease. A total of 1515 lesions were treated with 1682 Tetriflex SES of which 73.2% lesions were complex B2/C type and 14.7% were totally occluded. At 12 months, the cumulative incidence of TLF was 5.75% comprising 0.8% cardiac death, 3.20% TV-MI and 1.72% CD-TLR. All the incidences of definite/probable stent thrombosis (n = 4, 0.32%) were reported within 30 days of the index procedure. Twelve-month cumulative incidence of TLF in diabetic subgroup was 7.10%.
Conclusion: Twelve months clinical follow-up results of an ultrathin (60 µm), biodegradable polymer-coated Tetriflex SES, with unique LDZ-link, further clarify its safety and effectiveness in real-world, unselected Indian patients.