The Importance of Using CBI-LVC for Detecting Ectasia in Post-Refractive Eyes.

Beyoglu Eye Journal Pub Date : 2023-09-13 eCollection Date: 2023-01-01 DOI:10.14744/bej.2023.82542
Vanessa Ferraro, Renato Ambrósio, Paolo Vinciguerra, Riccardo Vinciguerra
{"title":"The Importance of Using CBI-LVC for Detecting Ectasia in Post-Refractive Eyes.","authors":"Vanessa Ferraro, Renato Ambrósio, Paolo Vinciguerra, Riccardo Vinciguerra","doi":"10.14744/bej.2023.82542","DOIUrl":null,"url":null,"abstract":"Dear Editor, We have read the article by Yilmaz et al. with great interest (1). The study aimed to detect subclinical ectasia in the fellow eye of two patients who underwent femtosecondassisted laser in situ keratomileusis surgery (FS LASIK) and developed post-LASIK clinical and topographical ectasia in the other eye, using the Corvis ST tonometer. The authors observed that, despite the topographical and clinical findings not being consistent with corneal ectasia, the corneal biomechanical index (CBI), tomographic biomechanical index (TBI), and Belin-Ambrósio Deviation Display values suggested biomechanical weakness. However, we would like to draw attention to an important aspect concerning the detection of ectasia in post-refractive eyes. It is worth noting that the CBI was specifically designed to distinguish between normal corneas from those affected by keratoconus, exhibiting a high level of sensitivity and specificity also when used alone (2). Moreover, TBI was developed as a combined parameter based on Scheimpflug imaging from the Pentacam (Oculus Optikgeräte GmbH) and biomechanical assessment from the Corvis ST, to advance the ability to detect clinical and subclinical ectasia. It has shown the ability in identifying ectasia when compared to alternative topometric, tomographic, and biomechanical parameters. It has exhibited a high sensitivity for detecting subclinical (fruste) ectasia, particularly in cases where one eye has obvious ectasia, whereas the other eye appears to have normal tomographic indices (3). Numerous studies have reported significant changes in corneal biomechanical properties post-refractive surgery (4-6). Hence, CBI and TBI resulting from the analysis of post-refractive corneas are going to be always altered. The modified corneal structure can lead to inaccurate interpretations and erroneous assessments when using these indices. Therefore, caution should be exercised when using them in the analysis of post-refractive corneas, as they were primarily developed to detect ectasia in normal corneas. We share the authors’ concern regarding the need for the early recognition of post-refractive ectasia to prevent potential complications, which could be managed effectively with corneal crosslinking, a procedure aimed at stabilizing the cornea and halting the progression of ectasia (7). In light of the increasing prevalence of refractive surgeries such as LASIK and PRK, it is crucial to employ precise and dependable methods for detecting potential complications in patients who have undergone these procedures. Therefore, we suggest to the authors the utilization of validated diagnostic techniques specifically designed for post-refractive Vanessa Ferraro,1 Renato Ambrósio Jr,2 Paolo Vinciguerra,1 Riccardo Vinciguerra3","PeriodicalId":8740,"journal":{"name":"Beyoglu Eye Journal","volume":"8 3","pages":"237-238"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/9e/f3/BEJ-8-237.PMC10521133.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Beyoglu Eye Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14744/bej.2023.82542","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Dear Editor, We have read the article by Yilmaz et al. with great interest (1). The study aimed to detect subclinical ectasia in the fellow eye of two patients who underwent femtosecondassisted laser in situ keratomileusis surgery (FS LASIK) and developed post-LASIK clinical and topographical ectasia in the other eye, using the Corvis ST tonometer. The authors observed that, despite the topographical and clinical findings not being consistent with corneal ectasia, the corneal biomechanical index (CBI), tomographic biomechanical index (TBI), and Belin-Ambrósio Deviation Display values suggested biomechanical weakness. However, we would like to draw attention to an important aspect concerning the detection of ectasia in post-refractive eyes. It is worth noting that the CBI was specifically designed to distinguish between normal corneas from those affected by keratoconus, exhibiting a high level of sensitivity and specificity also when used alone (2). Moreover, TBI was developed as a combined parameter based on Scheimpflug imaging from the Pentacam (Oculus Optikgeräte GmbH) and biomechanical assessment from the Corvis ST, to advance the ability to detect clinical and subclinical ectasia. It has shown the ability in identifying ectasia when compared to alternative topometric, tomographic, and biomechanical parameters. It has exhibited a high sensitivity for detecting subclinical (fruste) ectasia, particularly in cases where one eye has obvious ectasia, whereas the other eye appears to have normal tomographic indices (3). Numerous studies have reported significant changes in corneal biomechanical properties post-refractive surgery (4-6). Hence, CBI and TBI resulting from the analysis of post-refractive corneas are going to be always altered. The modified corneal structure can lead to inaccurate interpretations and erroneous assessments when using these indices. Therefore, caution should be exercised when using them in the analysis of post-refractive corneas, as they were primarily developed to detect ectasia in normal corneas. We share the authors’ concern regarding the need for the early recognition of post-refractive ectasia to prevent potential complications, which could be managed effectively with corneal crosslinking, a procedure aimed at stabilizing the cornea and halting the progression of ectasia (7). In light of the increasing prevalence of refractive surgeries such as LASIK and PRK, it is crucial to employ precise and dependable methods for detecting potential complications in patients who have undergone these procedures. Therefore, we suggest to the authors the utilization of validated diagnostic techniques specifically designed for post-refractive Vanessa Ferraro,1 Renato Ambrósio Jr,2 Paolo Vinciguerra,1 Riccardo Vinciguerra3
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
应用CBI-LVC检测屈光后眼散光的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
42
审稿时长
16 weeks
期刊最新文献
A Case of Autosomal Recessive Retinitis Pigmentosa with Vitelliform-Like Appearance at the Macula Associated with Novel MYO7A Variant P.Ser383TrpfsTer64. Choroidal Metastasis in Stage IV Lung Adenocarcinoma. Comparison of Automated Versus Manual Analysis Programs for Quantification of Corneal Nerve Morphology in Patients With or Without Type 2 Diabetes Mellitus. Comparison of Choroidal Vascularity Index, Retinal, and Optic Nerve Changes in Diabetes Mellitus Patients Without Diabetic Retinopathy. Efficacy and Safety of Topical Tacrolimus for Vernal Keratoconjunctivitis: A Systematic Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1