High-performance liquid chromatography-tandem mass spectrometry method for measuring cotinine and trans-3'-hydroxycotinine in bronchoalveolar lavage fluid of patients with e-cigarette, or vaping, product use-associated lung injury.
{"title":"High-performance liquid chromatography-tandem mass spectrometry method for measuring cotinine and trans-3'-hydroxycotinine in bronchoalveolar lavage fluid of patients with e-cigarette, or vaping, product use-associated lung injury.","authors":"Tiffany Seyler, Benjamin C Blount, Lanqing Wang","doi":"10.1093/jat/bkad077","DOIUrl":null,"url":null,"abstract":"<p><p>In 2019, nearly 3000 U.S. residents developed severe lung injury associated with recent use of e-cigarette or vaping products. The Centers for Disease Control and Prevention responded to the outbreak, which was formally defined as e-cigarette, or vaping, product use-associated lung injury (EVALI). Centers for Disease Control and Prevention Laboratory rapidly developed assays to analyze potentially harmful and addictive substances in bronchoalveolar lavage (BAL) fluid collected from EVALI case patients. This report describes the development and validation of a high-throughput isotope-dilution high performance liquid chromatography-tandem mass spectrometry method for measuring two nicotine biomarkers, cotinine (COT) and trans-3'-hydroxycotinine (HCT), in bronchoalveolar lavage fluid samples. COT and HCT are the major metabolites of nicotine, the addictive alkaloid presents in tobacco products. This method had good specificity and sensitivity. The limit of detection is 0.033 and 0.0165 ng/mL for COT and HCT, respectively, using only 200 µL of sample volume. The within-run and between-run precision were 2-10%. The overall accuracy, calculated from recovery in three different sample matrices spiked at three concentrations, was 94.8% and 93.6% for COT and HCT, respectively. This novel HPLC-MS-MS method was utilized to characterize recent tobacco exposure in EVALI case patients. This method is useful for characterizing tobacco exposure that may be related to acute and chronic lung injury.</p>","PeriodicalId":14905,"journal":{"name":"Journal of analytical toxicology","volume":" ","pages":"62-69"},"PeriodicalIF":2.3000,"publicationDate":"2024-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of analytical toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jat/bkad077","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
In 2019, nearly 3000 U.S. residents developed severe lung injury associated with recent use of e-cigarette or vaping products. The Centers for Disease Control and Prevention responded to the outbreak, which was formally defined as e-cigarette, or vaping, product use-associated lung injury (EVALI). Centers for Disease Control and Prevention Laboratory rapidly developed assays to analyze potentially harmful and addictive substances in bronchoalveolar lavage (BAL) fluid collected from EVALI case patients. This report describes the development and validation of a high-throughput isotope-dilution high performance liquid chromatography-tandem mass spectrometry method for measuring two nicotine biomarkers, cotinine (COT) and trans-3'-hydroxycotinine (HCT), in bronchoalveolar lavage fluid samples. COT and HCT are the major metabolites of nicotine, the addictive alkaloid presents in tobacco products. This method had good specificity and sensitivity. The limit of detection is 0.033 and 0.0165 ng/mL for COT and HCT, respectively, using only 200 µL of sample volume. The within-run and between-run precision were 2-10%. The overall accuracy, calculated from recovery in three different sample matrices spiked at three concentrations, was 94.8% and 93.6% for COT and HCT, respectively. This novel HPLC-MS-MS method was utilized to characterize recent tobacco exposure in EVALI case patients. This method is useful for characterizing tobacco exposure that may be related to acute and chronic lung injury.
期刊介绍:
The Journal of Analytical Toxicology (JAT) is an international toxicology journal devoted to the timely dissemination of scientific communications concerning potentially toxic substances and drug identification, isolation, and quantitation.
Since its inception in 1977, the Journal of Analytical Toxicology has striven to present state-of-the-art techniques used in toxicology labs. The peer-review process provided by the distinguished members of the Editorial Advisory Board ensures the high-quality and integrity of articles published in the Journal of Analytical Toxicology. Timely presentation of the latest toxicology developments is ensured through Technical Notes, Case Reports, and Letters to the Editor.