Vascular refilling depends on the ratio of blood volume to extracellular volume in hemodialysis patients.

IF 1.4 4区 医学 Q4 ENGINEERING, BIOMEDICAL International Journal of Artificial Organs Pub Date : 2023-10-01 Epub Date: 2023-09-25 DOI:10.1177/03913988231201905
Joachim Kron, Stefanie Broszeit, John Volkenandt, Til Leimbach, Susanne Kron
{"title":"Vascular refilling depends on the ratio of blood volume to extracellular volume in hemodialysis patients.","authors":"Joachim Kron,&nbsp;Stefanie Broszeit,&nbsp;John Volkenandt,&nbsp;Til Leimbach,&nbsp;Susanne Kron","doi":"10.1177/03913988231201905","DOIUrl":null,"url":null,"abstract":"<p><p>The ratio of blood volume to extracellular volume is approximately one to three under physiological conditions and also in stable chronic hemodialysis patients. Recently, it was found that this ratio remains unchanged during hemodialysis despite ultrafiltration. This would signify that the higher the ratio, the lower the refilling and vice versa. To test this hypothesis, treatment data of a previous study were re-analyzed. In 79 stable chronic hemodialysis patients, the refilling fraction was 0.749 ± 0.094. There was a significant negative correlation (<i>r</i> = -0.412; <i>p</i> < 0.001) between the blood volume to extracellular volume ratio and the refilling fraction. The blood volume to extracellular volume relationship seems to be a significant determinant of vascular refilling: the higher the ratio, the lower the refilling, and vice versa.</p>","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988231201905","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/25 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The ratio of blood volume to extracellular volume is approximately one to three under physiological conditions and also in stable chronic hemodialysis patients. Recently, it was found that this ratio remains unchanged during hemodialysis despite ultrafiltration. This would signify that the higher the ratio, the lower the refilling and vice versa. To test this hypothesis, treatment data of a previous study were re-analyzed. In 79 stable chronic hemodialysis patients, the refilling fraction was 0.749 ± 0.094. There was a significant negative correlation (r = -0.412; p < 0.001) between the blood volume to extracellular volume ratio and the refilling fraction. The blood volume to extracellular volume relationship seems to be a significant determinant of vascular refilling: the higher the ratio, the lower the refilling, and vice versa.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
血液透析患者的血管再充盈取决于血容量与细胞外容量的比值。
在生理条件下以及在稳定的慢性血液透析患者中,血容量与细胞外容量的比率约为一比三。最近,人们发现,尽管进行了超滤,但在血液透析过程中,这一比例保持不变。这意味着比率越高,再填充越低,反之亦然。为了验证这一假设,对先前研究的治疗数据进行了重新分析。在79名稳定的慢性血液透析患者中,再充盈分数为0.749 ± 0.094 = -0.412;p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Artificial Organs
International Journal of Artificial Organs 医学-工程:生物医学
CiteScore
3.40
自引率
5.90%
发文量
92
审稿时长
3 months
期刊介绍: The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.
期刊最新文献
Performance study of dual heart assisted control system based on SL-SMC physiological combination controller. Depurative capacity toward medium molecules of the dialyzer Toray NV-U® Hydrolink™: A new hydrophilic membrane to perform online hemodiafiltration. Assessment of haemolysis models for a positive-displacement total artificial heart. Dynamic VAD simulations: Performing accurate simulations of ventricular assist devices in interaction with the cardiovascular system. Flexible inner surface of polysulfone membranes prevents platelet adhesive protein adsorption and improves antithrombogenicity in vitro.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1