Evaluation of the clinical safety and performance of a narrow diameter (2.9 mm) bone-level implant: a 1-year prospective single-arm multicenter study.

IF 3.1 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Implant Dentistry Pub Date : 2023-09-19 DOI:10.1186/s40729-023-00495-x
Christian Walter, Keyvan Sagheb, Sebastian Blatt, Marcus Oliver Klein, Jan Herrmann, Johannes Kleinheinz, Bilal Al-Nawas
{"title":"Evaluation of the clinical safety and performance of a narrow diameter (2.9 mm) bone-level implant: a 1-year prospective single-arm multicenter study.","authors":"Christian Walter, Keyvan Sagheb, Sebastian Blatt, Marcus Oliver Klein, Jan Herrmann, Johannes Kleinheinz, Bilal Al-Nawas","doi":"10.1186/s40729-023-00495-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Narrow-diameter implants facilitate single-tooth restoration when interdental or inter-implant spaces and bone volume are inadequate for using standard diameter implants. This study reports the short-term data on the clinical safety and performance of a bone-level-tapered two-piece implant with a 2.9 mm diameter in the clinical practice setting. This study was retrospectively registered on March 1st, 2016 (NCT02699866).</p><p><strong>Methods: </strong>Implants were placed in partially healed extraction sockets of the central and lateral incisors in the mandible and lateral incisors in the maxilla for single-tooth replacement. The primary outcome was to assess implant survival at 12 months after placement. Secondary outcomes included implant success, pink esthetic score, marginal bone-level changes, and safety.</p><p><strong>Results: </strong>Twenty four males and 17 females with a mean age of 44.5 (± 18.3 standard deviation) received the implant. Three out of 41 implants were lost yielding a survival rate of 92.7% (95%-CI: 79.0%; 97.6%) at 1 year. One patient reported an ongoing foreign body sensation, pain, and/or dysesthesia at month 12. The average pink esthetic score at 6 months was 11.2 (95%-CI: 10.5; 11.9). The bone level was stable with a mean bone-level change of-0.3 mm (± 0.42 mm standard deviation) at 1 year after implantation. No serious adverse events or adverse device events were reported.</p><p><strong>Conclusions: </strong>The use of a 2.9 mm diameter bone-level-tapered implant is a safe and reliable treatment option for narrow tooth gaps at the indicated locations. Overall performance and good survival rates support their use in cases, where wider implants are unsuitable.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":"9 1","pages":"32"},"PeriodicalIF":3.1000,"publicationDate":"2023-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10509112/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-023-00495-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Narrow-diameter implants facilitate single-tooth restoration when interdental or inter-implant spaces and bone volume are inadequate for using standard diameter implants. This study reports the short-term data on the clinical safety and performance of a bone-level-tapered two-piece implant with a 2.9 mm diameter in the clinical practice setting. This study was retrospectively registered on March 1st, 2016 (NCT02699866).

Methods: Implants were placed in partially healed extraction sockets of the central and lateral incisors in the mandible and lateral incisors in the maxilla for single-tooth replacement. The primary outcome was to assess implant survival at 12 months after placement. Secondary outcomes included implant success, pink esthetic score, marginal bone-level changes, and safety.

Results: Twenty four males and 17 females with a mean age of 44.5 (± 18.3 standard deviation) received the implant. Three out of 41 implants were lost yielding a survival rate of 92.7% (95%-CI: 79.0%; 97.6%) at 1 year. One patient reported an ongoing foreign body sensation, pain, and/or dysesthesia at month 12. The average pink esthetic score at 6 months was 11.2 (95%-CI: 10.5; 11.9). The bone level was stable with a mean bone-level change of-0.3 mm (± 0.42 mm standard deviation) at 1 year after implantation. No serious adverse events or adverse device events were reported.

Conclusions: The use of a 2.9 mm diameter bone-level-tapered implant is a safe and reliable treatment option for narrow tooth gaps at the indicated locations. Overall performance and good survival rates support their use in cases, where wider implants are unsuitable.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
窄直径(2.9mm)骨水平植入物的临床安全性和性能评估:一项为期1年的前瞻性单臂多中心研究。
目的:当齿间或种植体间的空间和骨体积不足以使用标准直径的种植体时,窄直径种植体有助于单牙修复。本研究报告了在临床实践环境中直径为2.9mm的骨水平锥形两件式植入物的临床安全性和性能的短期数据。本研究于2016年3月1日进行了回顾性登记(NCT02699866)。主要结果是评估植入后12个月的植入存活率。次要结果包括植入成功率、粉红色美学评分、边缘骨水平变化和安全性。结果:男性24例,女性17例,平均年龄44.5岁(± 18.3标准偏差)接受植入物。41个植入物中有3个丢失,1年时存活率为92.7%(95%CI:79.0%;97.6%)。一名患者在第12个月时报告了持续的异物感、疼痛和/或感觉障碍。6个月时的平均粉红色美学评分为11.2(95%CI:10.5;11.9)。骨水平稳定,平均骨水平变化-0.3 mm(± 0.42mm标准偏差)。未报告严重不良事件或不良器械事件。结论:对于指定位置的狭窄牙缝,使用直径为2.9mm的骨水平锥形植入物是一种安全可靠的治疗选择。整体性能和良好的生存率支持它们在不适合更宽植入物的情况下使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Implant Dentistry
International Journal of Implant Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.70
自引率
7.40%
发文量
53
审稿时长
13 weeks
期刊介绍: The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.
期刊最新文献
Electroplated double-crowns on implants and teeth after up to 12 years- a retrospective clinical study. The impact of a 1 mm interimplant distance on the interproximal crestal bone height: a case report with a 10-year follow-up and literature review. Usefulness of a novel density measurement drill for evaluating cancellous bone density: correlation between CT value and drilling torque value in bovine ribs. Treatment of peri-implant mucositis using an Er:YAG laser or an ultrasonic device: a randomized, controlled clinical trial. Prediction models for the complication incidence and survival rate of dental implants-a systematic review and critical appraisal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1