Whole Blood Titanium Concentration after Limb Salvage Surgery with Three-Dimensional-Printed Ti6Al4V Implants.

IF 1.9 2区 医学 Q2 ORTHOPEDICS Clinics in Orthopedic Surgery Pub Date : 2023-10-01 Epub Date: 2023-07-27 DOI:10.4055/cios22366
Jong Woong Park, Se Hoon Jung, Jung Hwan Yang, June Hyuk Kim, Sung Eun Oh, Hyun Guy Kang
{"title":"Whole Blood Titanium Concentration after Limb Salvage Surgery with Three-Dimensional-Printed Ti6Al4V Implants.","authors":"Jong Woong Park,&nbsp;Se Hoon Jung,&nbsp;Jung Hwan Yang,&nbsp;June Hyuk Kim,&nbsp;Sung Eun Oh,&nbsp;Hyun Guy Kang","doi":"10.4055/cios22366","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Three-dimensional (3D)-printed customized implants can be fabricated and utilized for all bones with massive bone defects. The main safety issues with 3D-printed implants made of Ti6Al4V alloy are related to the release of metal debris and residual powder. In this study, we investigated the perioperative titanium concentrations in whole blood and peri-implant fluid samples of patients who underwent limb salvage surgery with a 3D-printed Ti6Al4V implant.</p><p><strong>Methods: </strong>Nineteen patients who underwent limb salvage surgery with 3D-printed Ti6Al4V implants were divided into two groups: the serial samples group and the follow-up group. To observe metal distribution and clearance in the body, serial samples of blood and peri-implant fluid from the surgical drain were prospectively collected for five patients in the serial samples group. For the remaining 14 patients who were followed up for more than a year, blood samples were collected only once.</p><p><strong>Results: </strong>In the serial samples group, the mean baseline titanium concentration was 0.78 µg/L (range, 0.1-2.2 µg/L): 3 patients showed peak concentration before the third postoperative month, while 2 patients still showed an increasing pattern at this point. Total titanium mass in the surgical drain showed a wash-out phenomenon in a week, with a significant uniform decrease (<i>p</i> = 0.04). In 14 patients in the follow-up group, the mean titanium concentration in the whole blood was 10.8 µg/L (range, 0.3-36.6 µg/L). For the 14 patients with a long-term follow-up, the aluminum and vanadium concentrations were all negligible.</p><p><strong>Conclusions: </strong>Whole blood titanium concentrations were higher after surgery using 3D-printed implants than after that using conventional orthopedic implants, but markedly lower than in patients with implant failure. None of the patients developed serious clinical adverse effects during follow-up.</p>","PeriodicalId":47648,"journal":{"name":"Clinics in Orthopedic Surgery","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ab/4c/cios-15-864.PMC10551683.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinics in Orthopedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4055/cios22366","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/27 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Three-dimensional (3D)-printed customized implants can be fabricated and utilized for all bones with massive bone defects. The main safety issues with 3D-printed implants made of Ti6Al4V alloy are related to the release of metal debris and residual powder. In this study, we investigated the perioperative titanium concentrations in whole blood and peri-implant fluid samples of patients who underwent limb salvage surgery with a 3D-printed Ti6Al4V implant.

Methods: Nineteen patients who underwent limb salvage surgery with 3D-printed Ti6Al4V implants were divided into two groups: the serial samples group and the follow-up group. To observe metal distribution and clearance in the body, serial samples of blood and peri-implant fluid from the surgical drain were prospectively collected for five patients in the serial samples group. For the remaining 14 patients who were followed up for more than a year, blood samples were collected only once.

Results: In the serial samples group, the mean baseline titanium concentration was 0.78 µg/L (range, 0.1-2.2 µg/L): 3 patients showed peak concentration before the third postoperative month, while 2 patients still showed an increasing pattern at this point. Total titanium mass in the surgical drain showed a wash-out phenomenon in a week, with a significant uniform decrease (p = 0.04). In 14 patients in the follow-up group, the mean titanium concentration in the whole blood was 10.8 µg/L (range, 0.3-36.6 µg/L). For the 14 patients with a long-term follow-up, the aluminum and vanadium concentrations were all negligible.

Conclusions: Whole blood titanium concentrations were higher after surgery using 3D-printed implants than after that using conventional orthopedic implants, but markedly lower than in patients with implant failure. None of the patients developed serious clinical adverse effects during follow-up.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三维印刷Ti6Al4V植入物保肢手术后的全血钛浓度。
背景:三维(3D)打印的定制植入物可以制造并用于所有具有巨大骨缺损的骨骼。由Ti6Al4V合金制成的3D打印植入物的主要安全问题与金属碎片和残余粉末的释放有关。在这项研究中,我们调查了接受3D打印Ti6Al4V植入物保肢手术的患者围手术期全血和植入物周围液体样本中的钛浓度。方法:将19例接受3D打印Ti6Al4V植入物保肢手术的患者分为两组:连续样本组和随访组。为了观察体内金属的分布和清除率,前瞻性地从手术引流管中收集了系列样本组中五名患者的血液和植入物周围液体。对于其余14名随访超过一年的患者,只采集了一次血样。结果:在系列样本组中,平均基线钛浓度为0.78µg/L(范围为0.1-2.2µg/L):3名患者在术后第三个月前出现峰值浓度,而2名患者此时仍呈增加模式。手术引流管中的总钛质量在一周内出现冲刷现象,并显著均匀下降(p=0.04)。随访组的14名患者全血中的平均钛浓度为10.8µg/L(范围为0.3-36.6µg/L)。对于14名长期随访的患者,铝和钒的浓度都可以忽略不计。结论:使用3D打印植入物进行手术后,全血钛浓度高于使用传统骨科植入物的手术后,但明显低于植入物失败患者。在随访期间,没有患者出现严重的临床不良反应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.50
自引率
4.00%
发文量
85
审稿时长
36 weeks
期刊最新文献
Atraumatic Sport-Related Medial Sesamoid Pain: Conservative Treatment Outcome and Magnetic Resonance Imaging Features. Cemented Versus Uncemented Reverse Shoulder Arthroplasty Treatment of Proximal Humerus Fractures: National Shoulder Arthroplasty Data from Türkiye. Comparison of Midterm Outcomes between All-Inside Arthroscopic and Open Modified Broström Procedures as Treatment for Chronic Ankle Instability. Does the Nonunion Rate of Atypical Femoral Fractures Differ According to Fracture Site?: A Meta-Analysis. Isolated Polyethylene Insert Exchange for Instability after Total Knee Arthroplasty: Comparable Survival Rates and Range of Motion and Improved Clinical Scores Regardless of Hyperextension.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1