Self-assessment of range of motion in patients undergoing surgery for a unilateral shoulder condition.

Eirik Solheim, Maja Rosenlund, Karen Gjørwad Ulsaker, Anagha P Parkar
{"title":"Self-assessment of range of motion in patients undergoing surgery for a unilateral shoulder condition.","authors":"Eirik Solheim, Maja Rosenlund, Karen Gjørwad Ulsaker, Anagha P Parkar","doi":"10.5152/j.aott.2023.22166","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to investigate the agreement of patient-assessed and researcher/physician-assessed measurements of the difference in range of motion between the unaffected and affected shoulders in 55 patients undergoing arthroscopic surgery for a unilateral shoulder condition.</p><p><strong>Methods: </strong>The investigation included 55 patients (17 women and 38 men; median age=53 years; range=26-74) with a symptomatic unilateral shoulder condition and a surgically treatable diagnosis. Images of a model/researcher performing active shoulder abduction, flexion, external rotation, and internal rotation were created. Each image was paired with a degree diagram or a level system (for internal rotation) on the back for the patient to accurately self-evaluate and record. Each patient was instructed to attentively examine the figures and perform the movements with the same posture as depicted. On the day of surgery, prior to the procedure, 2 independent researchers who were not involved in the patient's care used a standard goniometer to assess the same active movements that the patient had previously self-assessed. For agreement analyses, the intraclass correlation coefficient and Bland-Altman plots were calculated for continuous data (abduction, flexion, and external rotation), and Cohen's weighted kappa was calculated for ordinal categorical data (internal rotation).</p><p><strong>Results: </strong>The intraclass correlation coefficient for abduction, flexion, and external rotation was 0.93 (excellent) 95% CI (0.87, 0.96), 0.89 (good) 95% CI (0.81, 0.94), and 0.72 (moderate) 95% CI (0.52, 0.84), respectively. Cohen's kappa for internal rotation (measured as reaching levels on the back) was 0.63 (moderate).</p><p><strong>Conclusion: </strong>We believe that patient-assessed measurements of abduction (intraclass correlation coefficient 0.93) and flexion (intraclass correlation coefficient 0.89) can be used as a valid substitute (for measurements by a clinician or researcher). Patient-assessed measurements for external rotation (intraclass correlation coefficient 0.72) and internal rotation (kappa 0.63) are in moderate agreement and should be used more cautiously as substitutes.</p><p><strong>Level of evidence: </strong>Level II, Diagnostic Study.</p>","PeriodicalId":93854,"journal":{"name":"Acta orthopaedica et traumatologica turcica","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10837573/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica et traumatologica turcica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5152/j.aott.2023.22166","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study aimed to investigate the agreement of patient-assessed and researcher/physician-assessed measurements of the difference in range of motion between the unaffected and affected shoulders in 55 patients undergoing arthroscopic surgery for a unilateral shoulder condition.

Methods: The investigation included 55 patients (17 women and 38 men; median age=53 years; range=26-74) with a symptomatic unilateral shoulder condition and a surgically treatable diagnosis. Images of a model/researcher performing active shoulder abduction, flexion, external rotation, and internal rotation were created. Each image was paired with a degree diagram or a level system (for internal rotation) on the back for the patient to accurately self-evaluate and record. Each patient was instructed to attentively examine the figures and perform the movements with the same posture as depicted. On the day of surgery, prior to the procedure, 2 independent researchers who were not involved in the patient's care used a standard goniometer to assess the same active movements that the patient had previously self-assessed. For agreement analyses, the intraclass correlation coefficient and Bland-Altman plots were calculated for continuous data (abduction, flexion, and external rotation), and Cohen's weighted kappa was calculated for ordinal categorical data (internal rotation).

Results: The intraclass correlation coefficient for abduction, flexion, and external rotation was 0.93 (excellent) 95% CI (0.87, 0.96), 0.89 (good) 95% CI (0.81, 0.94), and 0.72 (moderate) 95% CI (0.52, 0.84), respectively. Cohen's kappa for internal rotation (measured as reaching levels on the back) was 0.63 (moderate).

Conclusion: We believe that patient-assessed measurements of abduction (intraclass correlation coefficient 0.93) and flexion (intraclass correlation coefficient 0.89) can be used as a valid substitute (for measurements by a clinician or researcher). Patient-assessed measurements for external rotation (intraclass correlation coefficient 0.72) and internal rotation (kappa 0.63) are in moderate agreement and should be used more cautiously as substitutes.

Level of evidence: Level II, Diagnostic Study.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
单侧肩部手术患者活动范围的自我评估。
目的:本研究旨在调查55名因单侧肩部疾病接受关节镜手术的患者中,患者评估和研究人员/医生评估的未受影响和受影响肩部之间运动范围差异的测量结果是否一致。方法:调查包括55名患者(17名女性和38名男性;中位年龄=53岁;范围=26-74),他们有症状性单侧肩部疾病,诊断为可手术治疗。创建了一个模型/研究人员进行主动肩部外展、屈曲、外旋和内旋的图像。每个图像都与背面的度数图或水平系统(用于内部旋转)配对,以便患者准确地自我评估和记录。指导每位患者仔细检查人物,并以与所示相同的姿势进行动作。手术当天,在手术前,两名未参与患者护理的独立研究人员使用标准角度计来评估患者之前自我评估的相同活动。对于一致性分析,对连续数据(外展、屈曲和外旋)计算组内相关系数和Bland-Altman图,对有序分类数据(内旋)计算Cohen加权kappa,0.89(良好)95%置信区间(0.81,0.94)和0.72(中等)95%可信区间(0.52,0.84)。Cohen内旋的kappa(在背部达到水平时测量)为0.63(中等)。结论:我们认为,患者评估的外展(组内相关系数0.93)和屈曲(组内相关性系数0.89)测量可以作为有效的替代(临床医生或研究人员的测量)。患者评估的外旋(组内相关系数0.72)和内旋(kappa 0.63)测量结果中等一致,应更谨慎地用作替代品。证据级别:二级,诊断性研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Assessment of spinopelvic relationship among Turkish orthopedic surgeons in total joint replacement: a survey. Asymptomatic iatrogenic bilateral occlusion of vertebral artery after atlantoaxial fusion: a case report. Bibliometric analysis of the Acta Orthopaedica et Traumatologica Turcica from 2013 to 2022. Comparison of autologous matrix-induced chondrogenesis and mosaicplasty in the treatment of osteochondral defects of the talus. Comparison of mechanical stability of modified pedicle screw fixator and unilateral lumbopelvic fixation for treating sacroiliac joint disruption: A finite element analysis study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1