The trapeziometacarpal screw home torque mechanism as a clinical indicator of the posterior joint ligament complex integrity: A cadaveric investigation
{"title":"The trapeziometacarpal screw home torque mechanism as a clinical indicator of the posterior joint ligament complex integrity: A cadaveric investigation","authors":"","doi":"10.1016/j.jht.2023.08.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>To date, no clinical test provides specific objective information on the integrity of key ligamentous support of the trapeziometacarpal (TMC) joint.</p></div><div><h3>Purpose</h3><p>To examine the potential of the TMC joint screw home torque mechanism (SHTM) in estimating the integrity of the posterior ligament complex in older adult population.</p></div><div><h3>Study Design</h3><p>Cross-sectional laboratory-based study.</p></div><div><h3>Methods</h3><p>Twenty cadaver hands presenting with various degrees of TMC joint degradation ranging from none to severe osteoarthritis<span><span> (OA) were radiographed in multiple positions to establish their degeneration status, joint mobility, and amount of dorsal </span>subluxation at rest and with the application of the SHTM. Comparisons and correlations between degeneration status, joint mobility, subluxation reduction and ligament status obtained from dissection were calculated.</span></p></div><div><h3>Results</h3><p><span>No significant statistical correlation was demonstrated with the subluxation reduction ratio of the SHTM and the combined ligament complex value however, a moderate negative correlation was found with dorsal central ligament injury at 21 Nm (</span><em>τ</em>b = −0.46, <em>p</em> < 0.05) and 34 Nm (<em>τ</em>b = −0.45, <em>p</em> < 0.05). A statistically significant reduction of radial subluxation of the TMC joint was observed between the subluxation at rest (M = 5.2, SD = 1.9) and subluxation with SHTM of 21 Nm (M = 4.4, SD = 2.4), <em>t</em> (19) = 3.2, <em>p =</em> 0.01, 95% CI [0.3, 1.4] and subluxation with SHTM of 34 Nm (M = 4.3, SD = 2.6), <em>t</em> (19) = 2.6, <em>p =</em> 0.02, 95% CI [0.2, 1.5].</p></div><div><h3>Conclusion</h3><p>Our results did not support the SHTM as indicator of the TMC posterior ligament complex integrity however, it demonstrated 100% stabilization effect with non-arthritic TMC population.</p></div>","PeriodicalId":54814,"journal":{"name":"Journal of Hand Therapy","volume":"37 3","pages":"Pages 388-396"},"PeriodicalIF":2.1000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hand Therapy","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0894113023001205","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background
To date, no clinical test provides specific objective information on the integrity of key ligamentous support of the trapeziometacarpal (TMC) joint.
Purpose
To examine the potential of the TMC joint screw home torque mechanism (SHTM) in estimating the integrity of the posterior ligament complex in older adult population.
Study Design
Cross-sectional laboratory-based study.
Methods
Twenty cadaver hands presenting with various degrees of TMC joint degradation ranging from none to severe osteoarthritis (OA) were radiographed in multiple positions to establish their degeneration status, joint mobility, and amount of dorsal subluxation at rest and with the application of the SHTM. Comparisons and correlations between degeneration status, joint mobility, subluxation reduction and ligament status obtained from dissection were calculated.
Results
No significant statistical correlation was demonstrated with the subluxation reduction ratio of the SHTM and the combined ligament complex value however, a moderate negative correlation was found with dorsal central ligament injury at 21 Nm (τb = −0.46, p < 0.05) and 34 Nm (τb = −0.45, p < 0.05). A statistically significant reduction of radial subluxation of the TMC joint was observed between the subluxation at rest (M = 5.2, SD = 1.9) and subluxation with SHTM of 21 Nm (M = 4.4, SD = 2.4), t (19) = 3.2, p = 0.01, 95% CI [0.3, 1.4] and subluxation with SHTM of 34 Nm (M = 4.3, SD = 2.6), t (19) = 2.6, p = 0.02, 95% CI [0.2, 1.5].
Conclusion
Our results did not support the SHTM as indicator of the TMC posterior ligament complex integrity however, it demonstrated 100% stabilization effect with non-arthritic TMC population.
期刊介绍:
The Journal of Hand Therapy is designed for hand therapists, occupational and physical therapists, and other hand specialists involved in the rehabilitation of disabling hand problems. The Journal functions as a source of education and information by publishing scientific and clinical articles. Regular features include original reports, clinical reviews, case studies, editorials, and book reviews.