{"title":"Bimodular femoral stems in primary total hip arthroplasty.","authors":"Jan Zajc, Samo K Fokter","doi":"10.1080/17434440.2023.2264177","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>This review critically examines the efficacy of dual-modular stems in primary total hip arthroplasty. Given the variability and non-comparability of certain femoral stem designs and stem-neck couplings, with some even being withdrawn from the market, this review offers an in-depth analysis of predominant implant performances.</p><p><strong>Areas covered: </strong>The paper explores a brief historical summary related to dual-modular stems, including the complications associated with their use, diagnostic tools for evaluation, analysis of both recalled and currently available models, as well as alternative therapeutic options. This information is pertinent for both clinical and research domains.</p><p><strong>Expert opinion: </strong>While dual-modular systems were initially touted to offer several advantages, the evidence substantiating these benefits has been ambiguous. Further, these systems introduce the risk of alternative complications. In specific cases involving patients with developmental hip dysplasia and certain proximal femoral deformities requiring complex reconstructions, dual-modular systems might be relevant. Nonetheless, the use of long interchangeable necks in patients with a body mass index above 30 kg/m<sup>2</sup> is discouraged, and pairing a long varus-oriented neck with an extra-long femoral head should be avoided in all patients.</p>","PeriodicalId":94006,"journal":{"name":"Expert review of medical devices","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Expert review of medical devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/17434440.2023.2264177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Introduction: This review critically examines the efficacy of dual-modular stems in primary total hip arthroplasty. Given the variability and non-comparability of certain femoral stem designs and stem-neck couplings, with some even being withdrawn from the market, this review offers an in-depth analysis of predominant implant performances.

Areas covered: The paper explores a brief historical summary related to dual-modular stems, including the complications associated with their use, diagnostic tools for evaluation, analysis of both recalled and currently available models, as well as alternative therapeutic options. This information is pertinent for both clinical and research domains.

Expert opinion: While dual-modular systems were initially touted to offer several advantages, the evidence substantiating these benefits has been ambiguous. Further, these systems introduce the risk of alternative complications. In specific cases involving patients with developmental hip dysplasia and certain proximal femoral deformities requiring complex reconstructions, dual-modular systems might be relevant. Nonetheless, the use of long interchangeable necks in patients with a body mass index above 30 kg/m2 is discouraged, and pairing a long varus-oriented neck with an extra-long femoral head should be avoided in all patients.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
原发性全髋关节置换术中的双模块股骨干。
引言:这篇综述严格检查了双模块柄在初次全髋关节置换术中的疗效。鉴于某些股骨柄设计和股骨颈管接头的可变性和不可比性,有些甚至已退出市场,本综述对主要植入物性能进行了深入分析。涵盖的领域:本文探讨了与双模块茎相关的简要历史总结,包括与使用相关的并发症、评估的诊断工具、对召回和当前可用模型的分析,以及替代治疗方案。这些信息适用于临床和研究领域。专家意见:虽然双模块化系统最初被吹捧为具有几个优势,但证明这些优势的证据并不明确。此外,这些系统引入了替代并发症的风险。在涉及发育性髋关节发育不良和某些股骨近端畸形需要复杂重建的特定病例中,双模块系统可能是相关的。尽管如此,在体重指数超过30的患者中使用可互换的长脖子 不鼓励使用kg/m2,所有患者都应避免将长内翻颈与超长股骨头配对。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Orphan and paediatric medical devices in Europe: recommendations to support their availability for on-label and off-label clinical indications. Medical device similarity analysis: a promising approach to medical device equivalence regulation. Delivery systems for transcatheter therapies of congenital heart disease. Evaluation and management of coronary artery disease in transcatheter aortic valve implantation candidates with severe aortic stenosis and coronary artery disease: technology and techniques. Transforming medical education: the impact of innovations in technology and medical devices.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1