Development of an Anthropomorphic Heterogeneous Female Pelvic Phantom and Its Comparison with a Homogeneous Phantom in Advance Radiation Therapy: Dosimetry Analysis.

Neha Yadav, Manisha Singh, Surendra P Mishra, Shahnawaz Ansari
{"title":"Development of an Anthropomorphic Heterogeneous Female Pelvic Phantom and Its Comparison with a Homogeneous Phantom in Advance Radiation Therapy: Dosimetry Analysis.","authors":"Neha Yadav,&nbsp;Manisha Singh,&nbsp;Surendra P Mishra,&nbsp;Shahnawaz Ansari","doi":"10.3390/medsci11030059","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Accurate dosimetry is crucial in radiotherapy to ensure optimal radiation dose delivery to the tumor while sparing healthy tissues. Traditional dosimetry techniques using homogeneous phantoms may not accurately represent the complex anatomical variations in cervical cancer patients, highlighting the need to compare dosimetry results obtained from different phantom models.</p><p><strong>Purpose: </strong>The aim of this study is to design and evaluate an anthropomorphic heterogeneous female pelvic (AHFP) phantom for radiotherapy quality assurance in cervical cancer treatment.</p><p><strong>Materials and method: </strong>Thirty RapidArc plans designed for cervical cancer patients were exported to both the RW3 homogeneous phantom and the anthropomorphic heterogeneous pelvic phantom. Dose calculations were performed using the anisotropic analytic algorithm (AAA), and the plans were delivered using a linear accelerator (LA). Dose measurements were obtained using a 0.6 cc ion chamber. The percentage (%) variation between planned and measured doses was calculated and analyzed. Additionally, relative dosimetry was performed for various target locations using RapidArc and IMRT treatment techniques. The AHFP phantom demonstrated excellent agreement between measured and expected dose distributions, making it a reliable quality assurance tool in radiotherapy.</p><p><strong>Results: </strong>The results reveal that the percentage variation between planned and measured doses for all RapidArc quality assurance (QA) plans using the AHFP phantom is 10.67% (maximum value), 2.31% (minimum value), and 6.89% (average value), with a standard deviation (SD) of 2.565 (t = 3.21604, <i>p</i> = 0.001063). Also, for the percentage of variation between homogeneous and AHFP phantoms, the t-value is -11.17016 and the <i>p</i>-value is <0.00001. The result is thus significant at <i>p</i> < 0.05. We can see that the outcomes differ significantly due to the influence of heterogeneous media. Also, the average gamma values in RapidArc plans are 0.29, 0.32, and 0.35 (g ≤ 1) and IMRT plans are 0.45, 0.44, and 0.42 (g ≤ 1) for targets 1, 2, and 3, respectively.</p><p><strong>Conclusion: </strong>The AHFP phantom results show more dose variability than homogenous phantom outcomes. Also, the AHFP phantom was found to be suitable for QA evaluation.</p>","PeriodicalId":74152,"journal":{"name":"Medical sciences (Basel, Switzerland)","volume":"11 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10535781/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical sciences (Basel, Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/medsci11030059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Accurate dosimetry is crucial in radiotherapy to ensure optimal radiation dose delivery to the tumor while sparing healthy tissues. Traditional dosimetry techniques using homogeneous phantoms may not accurately represent the complex anatomical variations in cervical cancer patients, highlighting the need to compare dosimetry results obtained from different phantom models.

Purpose: The aim of this study is to design and evaluate an anthropomorphic heterogeneous female pelvic (AHFP) phantom for radiotherapy quality assurance in cervical cancer treatment.

Materials and method: Thirty RapidArc plans designed for cervical cancer patients were exported to both the RW3 homogeneous phantom and the anthropomorphic heterogeneous pelvic phantom. Dose calculations were performed using the anisotropic analytic algorithm (AAA), and the plans were delivered using a linear accelerator (LA). Dose measurements were obtained using a 0.6 cc ion chamber. The percentage (%) variation between planned and measured doses was calculated and analyzed. Additionally, relative dosimetry was performed for various target locations using RapidArc and IMRT treatment techniques. The AHFP phantom demonstrated excellent agreement between measured and expected dose distributions, making it a reliable quality assurance tool in radiotherapy.

Results: The results reveal that the percentage variation between planned and measured doses for all RapidArc quality assurance (QA) plans using the AHFP phantom is 10.67% (maximum value), 2.31% (minimum value), and 6.89% (average value), with a standard deviation (SD) of 2.565 (t = 3.21604, p = 0.001063). Also, for the percentage of variation between homogeneous and AHFP phantoms, the t-value is -11.17016 and the p-value is <0.00001. The result is thus significant at p < 0.05. We can see that the outcomes differ significantly due to the influence of heterogeneous media. Also, the average gamma values in RapidArc plans are 0.29, 0.32, and 0.35 (g ≤ 1) and IMRT plans are 0.45, 0.44, and 0.42 (g ≤ 1) for targets 1, 2, and 3, respectively.

Conclusion: The AHFP phantom results show more dose variability than homogenous phantom outcomes. Also, the AHFP phantom was found to be suitable for QA evaluation.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
拟人化异种女性骨盆模型的研制及其与先进放射治疗中的同质模型的比较:剂量测定分析。
背景:准确的剂量测定在放射治疗中至关重要,以确保最佳的放射剂量输送到肿瘤,同时保护健康组织。使用均匀体模的传统剂量测定技术可能无法准确地代表癌症宫颈患者的复杂解剖变化,这突出了比较从不同体模模型获得的剂量测定结果的必要性。目的:本研究的目的是设计和评估一种用于保证癌症宫颈放疗质量的拟人化异种女性骨盆(AHFP)体模。材料和方法:将30例为癌症宫颈癌患者设计的RapidArc方案导出到RW3均质体模和非均质骨盆体模中。使用各向异性分析算法(AAA)进行剂量计算,并使用线性加速器(LA)交付计划。使用0.6cc的离子室获得剂量测量。计算并分析计划剂量和测量剂量之间的百分比(%)变化。此外,使用RapidArc和IMRT治疗技术对不同目标位置进行了相对剂量测定。AHFP体模在测量剂量分布和预期剂量分布之间表现出良好的一致性,使其成为放射治疗中可靠的质量保证工具。结果:结果显示,使用AHFP体模的所有RapidArc质量保证(QA)计划的计划剂量和测量剂量之间的百分比变化分别为10.67%(最大值)、2.31%(最小值)和6.89%(平均值),标准偏差(SD)为2.565(t=3.21604,p=0.001063),t值为-11.17016,p值为p<0.05。我们可以看到,由于异质媒体的影响,结果差异很大。此外,对于目标1、2和3,RapidArc计划的平均伽马值分别为0.29、0.32和0.35(g≤1),IMRT计划的平均伽玛值分别为0.45、0.44和0.42(g≤2)。结论:AHFP体模结果显示出比同质体模结果更大的剂量变异性。此外,AHFP体模被发现适用于QA评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
9.00
自引率
0.00%
发文量
0
审稿时长
6 weeks
期刊最新文献
Is Artificial Intelligence the Next Co-Pilot for Primary Care in Diagnosing and Recommending Treatments for Depression? Circulating microRNAs as Biomarkers of Various Forms of Epilepsy. Whole-Genome Sequencing of Resistance, Virulence and Regulation Genes in Extremely Resistant Strains of Pseudomonas aeruginosa. Impact of Continuous Positive Airway Pressure on Patient Outcomes in Acute Cardiogenic Pulmonary Edema Within Physician-Led Prehospital Care. Long-Term Management of Sleep Apnea-Hypopnea Syndrome: Efficacy and Challenges of Continuous Positive Airway Pressure Therapy-A Narrative Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1