{"title":"Test and Development of a Specialized Pipeline for Ventilator Calibration.","authors":"Junming Liu, Wenxiu Zheng, Ziyan Wang","doi":"10.1615/CritRevBiomedEng.2023048365","DOIUrl":null,"url":null,"abstract":"<p><p>A specialized Y-type pipeline is developed to replace medical disposable Y-type pipelines for ventilator calibration and to improve accuracy, providing a reference for improvement. According to the calibration specifications of ventilators, tests are performed on specialized pipelines and more to compare their data. Taking the tidal volume 400-mL detection point as an example, the calibration errors made by medical disposable pipelines and specialized pipelines are 6.2% and -0.8%, respectively, and the errors at other detection points are roughly the same. The accuracy of the specialized Y-type pipeline has significantly improved, reducing the impact of the pipeline on tidal volume calibration from more than 6% to less than 1%. The use of specialized pipelines can significantly improve the accuracy and qualification rate of calibration, reducing the consumption of disposable Y-type pipelines and thereby significantly reducing costs and increasing efficiency.</p>","PeriodicalId":94308,"journal":{"name":"Critical reviews in biomedical engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical reviews in biomedical engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1615/CritRevBiomedEng.2023048365","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A specialized Y-type pipeline is developed to replace medical disposable Y-type pipelines for ventilator calibration and to improve accuracy, providing a reference for improvement. According to the calibration specifications of ventilators, tests are performed on specialized pipelines and more to compare their data. Taking the tidal volume 400-mL detection point as an example, the calibration errors made by medical disposable pipelines and specialized pipelines are 6.2% and -0.8%, respectively, and the errors at other detection points are roughly the same. The accuracy of the specialized Y-type pipeline has significantly improved, reducing the impact of the pipeline on tidal volume calibration from more than 6% to less than 1%. The use of specialized pipelines can significantly improve the accuracy and qualification rate of calibration, reducing the consumption of disposable Y-type pipelines and thereby significantly reducing costs and increasing efficiency.