{"title":"Challenges Associated with Biological Safety Assessments for Drug-Device Combination Products.","authors":"Cheryl L M Stults, Diane Harper, Doris Zane","doi":"10.5731/pdajpst.2022.012822","DOIUrl":null,"url":null,"abstract":"<p><p>Biological safety assessments for drug-device combination products involve evaluation of the drug container closure and the device constituent part. When the device constituent part is the drug delivery system as well as the drug container closure system, both device and drug-based packaging standards have been deemed applicable. Approaches used for the biological safety assessment of medical devices differ from those used for pharmaceutical packaging/delivery systems. One area of difference is the extent to which chemical characterization with toxicological assessment is used either in addition to, or in place of, biological in vivo or in vitro tests. Differences also exist in the way nonclinical studies are used to evaluate the safety of medical devices or drug delivery systems. The lack of alignment in standards and guidance has resulted in confusion over what combination of tests and methods of evaluation constitute a biological safety assessment that will meet regulatory expectations for a drug-device combination product. The intent of this article is to discuss the challenges created when the packaging or delivery system is also a device constituent part of a drug-device combination product. Suggestions are offered regarding approaches that may be useful for conducting suitable biological safety assessments for drug-device combination products.</p>","PeriodicalId":19986,"journal":{"name":"PDA Journal of Pharmaceutical Science and Technology","volume":" ","pages":"100-124"},"PeriodicalIF":0.0000,"publicationDate":"2024-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PDA Journal of Pharmaceutical Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5731/pdajpst.2022.012822","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Biological safety assessments for drug-device combination products involve evaluation of the drug container closure and the device constituent part. When the device constituent part is the drug delivery system as well as the drug container closure system, both device and drug-based packaging standards have been deemed applicable. Approaches used for the biological safety assessment of medical devices differ from those used for pharmaceutical packaging/delivery systems. One area of difference is the extent to which chemical characterization with toxicological assessment is used either in addition to, or in place of, biological in vivo or in vitro tests. Differences also exist in the way nonclinical studies are used to evaluate the safety of medical devices or drug delivery systems. The lack of alignment in standards and guidance has resulted in confusion over what combination of tests and methods of evaluation constitute a biological safety assessment that will meet regulatory expectations for a drug-device combination product. The intent of this article is to discuss the challenges created when the packaging or delivery system is also a device constituent part of a drug-device combination product. Suggestions are offered regarding approaches that may be useful for conducting suitable biological safety assessments for drug-device combination products.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
与药物-器械组合产品的生物安全性评估相关的挑战。
药物-器械组合产品的生物安全性评估包括对药物容器闭合和器械组成部分的评估。当装置的组成部分是药物输送系统和药物容器封闭系统时,装置和基于药物的包装标准都被认为是适用的。用于医疗器械生物安全评估的方法与用于药物包装/递送系统的方法不同。一个不同的领域是,除了体内或体外生物测试外,或代替体内或体外生物学测试,使用具有毒理学评估的化学表征的程度。非临床研究用于评估医疗器械或药物输送系统安全性的方式也存在差异。标准和指南缺乏一致性,导致人们对什么样的测试和评估方法组合才能构成生物安全评估感到困惑,从而满足监管部门对药物器械组合产品的期望。本手稿的目的是讨论当包装或递送系统也是药物-器械组合产品的器械组成部分时所产生的挑战。就可能有助于对药物器械组合产品进行适当的生物安全性评估的方法提出了建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
34
期刊最新文献
Addressing Medical Device Extractables and Leachables via Non-Target Analysis (NTA); The Analytical Evaluation Threshold (AET) and Quantitation. Definition of particle visibility threshold in parenteral drug products - towards standardization of visual inspection operator qualification. Recommendations for Artificial Intelligence Application in Continued Process Verification. Comparing Container Closure Integrity Test Methods-Performance of Headspace Carbon Dioxide Analysis versus Helium Leakage Using Positive Controls. Case Studies on Changes and Proposed Process Development Approaches Reflecting Applicability of PDA Technical Report No. 89: Strategies for Vaccine Development and Lifecycle Management.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1