Carbohydrate–protein interaction-based detection of pathogenic bacteria using a biodegradable self-powered biosensor†

IF 6.1 3区 医学 Q1 MATERIALS SCIENCE, BIOMATERIALS Journal of Materials Chemistry B Pub Date : 2023-10-11 DOI:10.1039/D3TB01820B
Swati Panda, Sugato Hajra, Hang Gyeom Kim, Haejin Jeong, P. G. R. Achary, Seonki Hong, Bhaskar Dudem, S. Ravi P. Silva, Venkateswaran Vivekananthan and Hoe Joon Kim
{"title":"Carbohydrate–protein interaction-based detection of pathogenic bacteria using a biodegradable self-powered biosensor†","authors":"Swati Panda, Sugato Hajra, Hang Gyeom Kim, Haejin Jeong, P. G. R. Achary, Seonki Hong, Bhaskar Dudem, S. Ravi P. Silva, Venkateswaran Vivekananthan and Hoe Joon Kim","doi":"10.1039/D3TB01820B","DOIUrl":null,"url":null,"abstract":"<p >Battery-free and biodegradable sensors can detect biological elements in remote areas. The triboelectric nanogenerator (TENG) can potentially eliminate the need for a battery by simply converting the abundant vibrations from nature or human motion into electricity. A biodegradable sensor system integrated with TENG to detect commonly found disease-causing bacteria (<em>E. coli</em>) in the environment is showcased herein. In this system, <small>D</small>-mannose functionalized 3D printed polylactic acid (PLA) with the brush-painted silver electrode was used to detect <em>E. coli</em> by a simple carbohydrate–protein interaction mechanism. The adsorption capacity of <small>D</small>-mannose is generally altered by varying the concentration of <em>E. coli</em> resulting in changes in resistance. Thus, the presented biosensor can detect bacterial concentrations by monitoring the output current. The PLA TENG generates an output of 70 V, 800 nA, and 22 nC, respectively. In addition, tap water and unpasteurized milk samples are tested for detecting bacteria, and the output is measured at 6 μA and 5 μA, respectively. Further, the biosensor was tested for biodegradability in soil compost by maintaining constant temperature and humidity. This study not only proposes an efficient and fast method for screening <em>E. coli</em> but also gives important insights into the ability to degrade and long-term reliability of TENG-based sensor platforms.</p>","PeriodicalId":83,"journal":{"name":"Journal of Materials Chemistry B","volume":" 42","pages":" 10147-10157"},"PeriodicalIF":6.1000,"publicationDate":"2023-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Materials Chemistry B","FirstCategoryId":"1","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2023/tb/d3tb01820b","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Battery-free and biodegradable sensors can detect biological elements in remote areas. The triboelectric nanogenerator (TENG) can potentially eliminate the need for a battery by simply converting the abundant vibrations from nature or human motion into electricity. A biodegradable sensor system integrated with TENG to detect commonly found disease-causing bacteria (E. coli) in the environment is showcased herein. In this system, D-mannose functionalized 3D printed polylactic acid (PLA) with the brush-painted silver electrode was used to detect E. coli by a simple carbohydrate–protein interaction mechanism. The adsorption capacity of D-mannose is generally altered by varying the concentration of E. coli resulting in changes in resistance. Thus, the presented biosensor can detect bacterial concentrations by monitoring the output current. The PLA TENG generates an output of 70 V, 800 nA, and 22 nC, respectively. In addition, tap water and unpasteurized milk samples are tested for detecting bacteria, and the output is measured at 6 μA and 5 μA, respectively. Further, the biosensor was tested for biodegradability in soil compost by maintaining constant temperature and humidity. This study not only proposes an efficient and fast method for screening E. coli but also gives important insights into the ability to degrade and long-term reliability of TENG-based sensor platforms.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用可生物降解的自供电生物传感器进行基于碳水化合物-蛋白质相互作用的致病菌检测。
无电池和可生物降解传感器可以检测偏远地区的生物元素。摩擦电纳米发电机(TENG)可以通过简单地将自然界或人类运动产生的丰富振动转化为电能,从而潜在地消除对电池的需求。本文展示了一种与TENG集成的可生物降解传感器系统,用于检测环境中常见的致病细菌(大肠杆菌)。在该系统中,使用刷涂银电极的D-甘露糖功能化3D打印聚乳酸(PLA),通过简单的碳水化合物-蛋白质相互作用机制检测大肠杆菌。D-甘露糖的吸附能力通常通过改变大肠杆菌的浓度而改变,从而导致耐药性的变化。因此,所提出的生物传感器可以通过监测输出电流来检测细菌浓度。PLA TENG分别产生70V、800nA和22nC的输出。此外,对自来水和未经高温消毒的牛奶样本进行细菌检测,输出分别在6μA和5μA下测量。此外,通过保持恒定的温度和湿度,测试了生物传感器在土壤堆肥中的生物降解性。这项研究不仅提出了一种高效快速的大肠杆菌筛选方法,还对基于TENG的传感器平台的降解能力和长期可靠性提供了重要见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Materials Chemistry B
Journal of Materials Chemistry B MATERIALS SCIENCE, BIOMATERIALS-
CiteScore
11.50
自引率
4.30%
发文量
866
期刊介绍: Journal of Materials Chemistry A, B & C cover high quality studies across all fields of materials chemistry. The journals focus on those theoretical or experimental studies that report new understanding, applications, properties and synthesis of materials. Journal of Materials Chemistry A, B & C are separated by the intended application of the material studied. Broadly, applications in energy and sustainability are of interest to Journal of Materials Chemistry A, applications in biology and medicine are of interest to Journal of Materials Chemistry B, and applications in optical, magnetic and electronic devices are of interest to Journal of Materials Chemistry C.Journal of Materials Chemistry B is a Transformative Journal and Plan S compliant. Example topic areas within the scope of Journal of Materials Chemistry B are listed below. This list is neither exhaustive nor exclusive: Antifouling coatings Biocompatible materials Bioelectronics Bioimaging Biomimetics Biomineralisation Bionics Biosensors Diagnostics Drug delivery Gene delivery Immunobiology Nanomedicine Regenerative medicine & Tissue engineering Scaffolds Soft robotics Stem cells Therapeutic devices
期刊最新文献
Back cover Back cover Back cover Expression of concern: Surface modification engineering of two-dimensional titanium carbide for efficient synergistic multitherapy of breast cancer Reconfiguring the endogenous electric field of a wound through a conductive hydrogel for effective exudate management to enhance skin wound healing†
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1