Preventing Stroke in Sickle Cell Disease: 2021. The Role of Transcranial Doppler Ultrasound (TCD) When the Use of Transfusion is Problematic

R. Adams
{"title":"Preventing Stroke in Sickle Cell Disease: 2021. The Role of Transcranial Doppler Ultrasound (TCD) When the Use of Transfusion is Problematic","authors":"R. Adams","doi":"10.33696/haematology.2.035","DOIUrl":null,"url":null,"abstract":"In 2009, as an invited Commentary to the article: “STOP” ing the Harm: When is State Intervention Justified? [1], I wrote that while TCD is an indicator of risk, not a biopsy diagnosis (such as proof of cancer), at some point in the velocity spectrum the high velocity detected by TCD reaches what many—myself included--believe is an unacceptable risk of stroke [2]. Even at the low end of the intervention window, 200 cm/sec Time Averaged Mean of the Maximum (TAMM), the point where periodic transfusion is recommended based on the STOP Trial [3], the risk is at least 10 times background and it goes up from there. The risk is markedly attenuated (>90%) by transfusion. Stroke by its nature is permanent. While some strokes are minor and survival with recovery is the expected outcome, it is not assured.","PeriodicalId":87297,"journal":{"name":"Journal of clinical haematology","volume":"18 10","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical haematology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33696/haematology.2.035","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In 2009, as an invited Commentary to the article: “STOP” ing the Harm: When is State Intervention Justified? [1], I wrote that while TCD is an indicator of risk, not a biopsy diagnosis (such as proof of cancer), at some point in the velocity spectrum the high velocity detected by TCD reaches what many—myself included--believe is an unacceptable risk of stroke [2]. Even at the low end of the intervention window, 200 cm/sec Time Averaged Mean of the Maximum (TAMM), the point where periodic transfusion is recommended based on the STOP Trial [3], the risk is at least 10 times background and it goes up from there. The risk is markedly attenuated (>90%) by transfusion. Stroke by its nature is permanent. While some strokes are minor and survival with recovery is the expected outcome, it is not assured.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
预防镰状细胞病卒中:2021。经颅多普勒超声(TCD)在输血使用有问题时的作用
2009年,作为一篇文章的特邀评论:“停止伤害:什么时候国家干预是合理的?”我写道,虽然TCD是一种风险指标,而不是活检诊断(如癌症的证据),但在速度谱的某个点上,TCD检测到的高速度达到了许多人(包括我自己)认为的不可接受的中风风险。即使在干预窗口的低端,200厘米/秒的最大平均时间(TAMM),根据停止试验[3]建议定期输血的点,风险至少是背景的10倍,并且从那里开始上升。输血可显著降低风险(约90%)。中风本质上是永久性的。虽然有些中风是轻微的,预期的结果是恢复生存,但这并不能保证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of Updates in Multiple Myeloma Treatment and Management Molecular Features Associated with Response to Enasidenib Plus Azacitidine in Newly Diagnosed IDH2-Mutated Acute Myeloid Leukemia A Rare Blood Malignancy in a Genetic Hematological Disorder: Polycythemia Vera (PV) in Sickle Cell Disease (SCD) Thrombotic Events and Risk Factors for Thrombosis in Polycythemia in Senegal, West Africa Making a Rationale Decision About -Uses of FFP: A Study at the Blood Bank of Tertiary Care Hospital of Southern Rajasthan
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1