Use of Extra-Narrow-Diameter Implants in Reduced Alveolar Ridge: A Case Report

C. Mattos, M. A. Carvalho, J. J. Carvalho, P. Santos, J. Pires, I. Brum
{"title":"Use of Extra-Narrow-Diameter Implants in Reduced Alveolar Ridge: A Case Report","authors":"C. Mattos, M. A. Carvalho, J. J. Carvalho, P. Santos, J. Pires, I. Brum","doi":"10.4236/jbnb.2020.112007","DOIUrl":null,"url":null,"abstract":"Background: Narrow-diameter implants (3.0 - 3.5 mm range) have been introduced for the replacement of teeth with insufficient bone structure and/or limited mesiodistal or interimplant spaces, and appear to offer clinical results similar to those obtained with implants of greater diameter. Studies using extra-narrow-diameter implants (2.8 mm) are scarce. Case Presentation: A 59-year-old male patient received two extra-narrow-diameter implants, 2.8 × 11 mm in the region between elements 11 and 14. Together, two 3.5 × 8.5 mm SYSTHEX® platform 4.1 implants were installed in the region of elements 15 and 16 to provide greater stability in the occlusion. Of four previous implants on the maxillary left side, one in the region between the elements 23 and 24 that was located in a very apical position and vestibularized was removed. The provisional was already installed on the elements 11, 21, and 22 with the metal cores already prepared and with the Globteck® implants in the region of the elements 23, 24, and 27. The functional and esthetic results were satisfactory. Conclusions: Insertion of extra-narrow-diameter implants of 2.8 mm in the maxillary anterior region is a reliable option in a patient with absence of elements 12 and 13, restoring masticatory function and aesthetics in the upper arch.","PeriodicalId":68623,"journal":{"name":"生物材料与纳米技术(英文)","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"生物材料与纳米技术(英文)","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.4236/jbnb.2020.112007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Narrow-diameter implants (3.0 - 3.5 mm range) have been introduced for the replacement of teeth with insufficient bone structure and/or limited mesiodistal or interimplant spaces, and appear to offer clinical results similar to those obtained with implants of greater diameter. Studies using extra-narrow-diameter implants (2.8 mm) are scarce. Case Presentation: A 59-year-old male patient received two extra-narrow-diameter implants, 2.8 × 11 mm in the region between elements 11 and 14. Together, two 3.5 × 8.5 mm SYSTHEX® platform 4.1 implants were installed in the region of elements 15 and 16 to provide greater stability in the occlusion. Of four previous implants on the maxillary left side, one in the region between the elements 23 and 24 that was located in a very apical position and vestibularized was removed. The provisional was already installed on the elements 11, 21, and 22 with the metal cores already prepared and with the Globteck® implants in the region of the elements 23, 24, and 27. The functional and esthetic results were satisfactory. Conclusions: Insertion of extra-narrow-diameter implants of 2.8 mm in the maxillary anterior region is a reliable option in a patient with absence of elements 12 and 13, restoring masticatory function and aesthetics in the upper arch.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超窄径种植体治疗牙槽嵴缩小1例报告
背景:窄直径种植体(3.0-3.5 mm范围)已被引入用于替换骨结构不足和/或近中或种植间隙有限的牙齿,并且似乎提供了与较大直径种植体相似的临床结果。使用超窄直径植入物(2.8毫米)的研究很少。病例介绍:一名59岁男性患者接受了两个超窄直径植入物,在元件11和14之间的区域为2.8×11 mm。两个3.5×8.5 mm SYSTHEX®平台4.1植入物一起安装在元件15和16的区域,以提供更大的咬合稳定性。在上颌左侧先前的四个植入物中,位于元件23和24之间的区域中的一个位于非常顶端的位置并且前庭化的植入物被移除。临时支架已经安装在元件11、21和22上,金属芯已经准备好,Globtec®植入物位于元件23、24和27的区域。功能和美观效果令人满意。结论:对于没有元件12和13的患者,在上颌前部区域插入2.8 mm的超窄直径植入物是一种可靠的选择,可以恢复上弓的咀嚼功能和美观。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
317
期刊最新文献
The Role of Biosynthesized Metallic and Metal Oxide Nanoparticles in Combating Anti-Microbial Drug Resilient Pathogens In Vitro Evaluation of Two Tissue Substitutes for Gingival Augmentation Comparison between Four Types of Buffers for DNA Agarose Gel Electrophoresis Toxicity and Molecular Mechanisms of Actions of Silver Nanoparticles Natural Nanoskin Advanced Cell Therapy (ACT) and Nanoskin ACT Soft towards the Definitive Solution for Acute and Chronic Wounds
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1