Value of chest CT screening in the early COVID-19 outbreak

Zhiqing Deng, Xiaochun Zhang, Yirong Li, Haibo Xu, Yadong Gang, Han-lun Wang, Rufang Liao, Ying-hui Jin, Xing-huan Wang, Xian-Tao Zeng, S. Luo, Z. Pan
{"title":"Value of chest CT screening in the early COVID-19 outbreak","authors":"Zhiqing Deng, Xiaochun Zhang, Yirong Li, Haibo Xu, Yadong Gang, Han-lun Wang, Rufang Liao, Ying-hui Jin, Xing-huan Wang, Xian-Tao Zeng, S. Luo, Z. Pan","doi":"10.3760/CMA.J.CN112149-20200218-00187","DOIUrl":null,"url":null,"abstract":"Objective \nIn view of the difficulty of the shortage of new coronavirus nucleal acid test in the early COVID-19 outbreak, to explore the application value of chest CT in screening COVID-19 patients. \n \n \nMethods \nRetrospective analysis was performed on the data of patients with fever who received chest CT and new coronavirus nucleal acid test during January 25, 2020 to February 2, 2020 in Zhongnan Hospital of Wuhan University. A total of 587 patients were enrolled, including 290 males and 297 females, aged from 11.0 to 96.0 (51.3±17.1) years old. Take the nucleic acid test results as the gold standard, the sensitivity, specificity and rate of missed diagnosis of CT screening COVID-19 were calculated. \n \n \nResults \nAmong the 587 patients, there were 433 positive cases (73.8%, 433/587) and 154 negative cases (26.2%, 154/587) of novel coronavirus nucleic acid test. Using CT screening, 494 cases (84.2%, 494/587) were positive and 93 cases (15.8%, 93/587) were negative. The sensitivity of CT screening COVID-19 was 97.7% (423/433), specificity was 53.9% (83/154) and rate of missed diagnosis was 2.3% (10/433). \n \n \nConclusions \nIn the early COVID-19 outbreak, CT screening has the advantages of high sensitivity and low rate of missed diagnosis of COVID-19, which can compensate for the shortage of new coronavirus nucleal acid test and can be used as the basis for rapid screening for early prevention and control of COVID-19 outbreak. \n \n \nKey words: \nCOVID-19; Tomography, X-ray computed; Diagnostic test; Sensitivity","PeriodicalId":39377,"journal":{"name":"Zhonghua fang she xue za zhi Chinese journal of radiology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua fang she xue za zhi Chinese journal of radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.CN112149-20200218-00187","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 9

Abstract

Objective In view of the difficulty of the shortage of new coronavirus nucleal acid test in the early COVID-19 outbreak, to explore the application value of chest CT in screening COVID-19 patients. Methods Retrospective analysis was performed on the data of patients with fever who received chest CT and new coronavirus nucleal acid test during January 25, 2020 to February 2, 2020 in Zhongnan Hospital of Wuhan University. A total of 587 patients were enrolled, including 290 males and 297 females, aged from 11.0 to 96.0 (51.3±17.1) years old. Take the nucleic acid test results as the gold standard, the sensitivity, specificity and rate of missed diagnosis of CT screening COVID-19 were calculated. Results Among the 587 patients, there were 433 positive cases (73.8%, 433/587) and 154 negative cases (26.2%, 154/587) of novel coronavirus nucleic acid test. Using CT screening, 494 cases (84.2%, 494/587) were positive and 93 cases (15.8%, 93/587) were negative. The sensitivity of CT screening COVID-19 was 97.7% (423/433), specificity was 53.9% (83/154) and rate of missed diagnosis was 2.3% (10/433). Conclusions In the early COVID-19 outbreak, CT screening has the advantages of high sensitivity and low rate of missed diagnosis of COVID-19, which can compensate for the shortage of new coronavirus nucleal acid test and can be used as the basis for rapid screening for early prevention and control of COVID-19 outbreak. Key words: COVID-19; Tomography, X-ray computed; Diagnostic test; Sensitivity
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
胸部CT筛查在早期新冠肺炎暴发中的价值
目的针对新型冠状病毒核酸检测在早期COVID-19疫情中缺乏的困难,探讨胸部CT在筛查COVID-19患者中的应用价值。方法回顾性分析武汉大学中南医院2020年1月25日至2020年2月2日接受胸部CT和新型冠状病毒核酸检测的发热患者资料。共纳入587例患者,其中男性290例,女性297例,年龄11.0 ~ 96.0(51.3±17.1)岁。以核酸检测结果为金标准,计算CT筛查COVID-19的敏感性、特异性和漏诊率。结果587例患者中,新型冠状病毒核酸检测阳性433例(73.8%,433/587),阴性154例(26.2%,154/587)。CT筛查阳性494例(84.2%,494/587),阴性93例(15.8%,93/587)。CT筛查新冠肺炎的敏感性为97.7%(423/433),特异性为53.9%(83/154),漏诊率为2.3%(10/433)。结论在COVID-19早期疫情中,CT筛查具有敏感性高、漏诊率低的优势,可弥补新型冠状病毒核酸试验的不足,可作为快速筛查的基础,为COVID-19的早期防控提供依据。关键词:COVID-19;断层扫描,x射线计算机;诊断测试;灵敏度
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Zhonghua fang she xue za zhi Chinese journal of radiology
Zhonghua fang she xue za zhi Chinese journal of radiology Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
0.30
自引率
0.00%
发文量
10639
期刊最新文献
Study progress of cerebrovascular interventional surgery robot Value of chest CT screening in the early COVID-19 outbreak Imaging dynamic observation of cured COVID-19 patients with imported coronavirus pneumonia/ 输入性新型冠状病毒肺炎治愈患者肺内病变的影像学动态观察 The diagnostic value of chest CT imaging in differential diagnosis between common-type COVID-19 and mycoplasma pneumonia/ 胸部CT在普通型新型冠状病毒肺炎与支原体肺炎鉴别诊断中的价值 The role of medical imaging in the diagnosis and treatment of COVID-19
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1