Novel electrode design reduces sensory threshold current drift during peripheral nerve evaluation in patients considered for sacral nerve stimulation

IF 0.2 Q4 UROLOGY & NEPHROLOGY Journal of Clinical Urology Pub Date : 2022-09-19 DOI:10.1177/20514158221123997
Je Song Shin, Duncan G Middleton, D. Small, Lisa Cochrane, S. Morton, I. G. Conn
{"title":"Novel electrode design reduces sensory threshold current drift during peripheral nerve evaluation in patients considered for sacral nerve stimulation","authors":"Je Song Shin, Duncan G Middleton, D. Small, Lisa Cochrane, S. Morton, I. G. Conn","doi":"10.1177/20514158221123997","DOIUrl":null,"url":null,"abstract":"To retrospectively compare the efficacy and technical performance of a novel lead used for percutaneous nerve evaluation (PNE) during the testing phase for sacral nerve neuromodulation with the existing lead currently used. Sixty-three PNE leads were inserted in 45 consecutive patients who underwent PNE with the novel helical electrodes, and the intra-operative and return clinic sensory threshold currents were recorded. This resulted in current measurements for 63 individual electrodes. Measurements were compared with 46 consecutive patients who previously underwent PNE using the standard lead with measurements for 63 individual electrodes. Current difference distributions for the two leads were compared using a Wilcoxon signed-rank test. There was a statistically significant difference observed between the two types of PNE electrode. The new PNE lead demonstrated less drift in sensory threshold current during a 12-day test period in comparison to the old lead. The novel helical PNE electrodes demonstrate a significant improvement in current drift compared with the old style leads over a 12-day test period. Level III","PeriodicalId":15471,"journal":{"name":"Journal of Clinical Urology","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2022-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Urology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/20514158221123997","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

To retrospectively compare the efficacy and technical performance of a novel lead used for percutaneous nerve evaluation (PNE) during the testing phase for sacral nerve neuromodulation with the existing lead currently used. Sixty-three PNE leads were inserted in 45 consecutive patients who underwent PNE with the novel helical electrodes, and the intra-operative and return clinic sensory threshold currents were recorded. This resulted in current measurements for 63 individual electrodes. Measurements were compared with 46 consecutive patients who previously underwent PNE using the standard lead with measurements for 63 individual electrodes. Current difference distributions for the two leads were compared using a Wilcoxon signed-rank test. There was a statistically significant difference observed between the two types of PNE electrode. The new PNE lead demonstrated less drift in sensory threshold current during a 12-day test period in comparison to the old lead. The novel helical PNE electrodes demonstrate a significant improvement in current drift compared with the old style leads over a 12-day test period. Level III
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新颖的电极设计减少了骶神经刺激患者周围神经评估过程中的感觉阈值电流漂移
回顾性比较一种用于经皮神经评估(PNE)的新型铅在骶神经神经调节测试阶段与目前使用的铅的疗效和技术性能。在45例连续接受PNE手术的患者中插入63根PNE导联,记录术中和临床返回时的感觉阈值电流。这导致了63个单独电极的电流测量。将先前使用标准导线进行PNE治疗的46例连续患者的测量结果与63个单独电极的测量结果进行比较。使用Wilcoxon符号秩检验比较两导联的电流差异分布。两种PNE电极之间的差异有统计学意义。在12天的测试期间,与旧导线相比,新的PNE导线显示出更少的感觉阈值电流漂移。在12天的测试期间,新型螺旋PNE电极与老式引线相比,在电流漂移方面有显着改善。第三级
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Clinical Urology
Journal of Clinical Urology UROLOGY & NEPHROLOGY-
CiteScore
0.60
自引率
0.00%
发文量
0
期刊最新文献
Diagnostic value of the abnormal digital rectal examination in the modern MRI-based prostate cancer diagnostic pathway. Comparison of the diagnostic utility of CHOKAI, STONE and STONE PLUS scores in predicting ureteral stones larger than 5 mm Quality of life and healthcare resource use in patients with bladder pain syndrome: A survey of UK patients Analysis of the learning curve for Retzius-sparing robot-assisted radical prostatectomy for a single surgeon Effectiveness of intravesical glycosaminoglycans in the treatment of recurrent urinary tract infections: Systematic review and meta-analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1