Toward a greener approach to detect inorganic arsenic using the Gutzeit method and X-ray fluorescence spectroscopy

IF 3 Q2 CHEMISTRY, ANALYTICAL Analytical science advances Pub Date : 2022-09-16 DOI:10.1002/ansa.202200014
Helen Lin, Haochen Dai, Lili He
{"title":"Toward a greener approach to detect inorganic arsenic using the Gutzeit method and X-ray fluorescence spectroscopy","authors":"Helen Lin,&nbsp;Haochen Dai,&nbsp;Lili He","doi":"10.1002/ansa.202200014","DOIUrl":null,"url":null,"abstract":"<p>Inorganic arsenic is a carcinogen repeatedly found in water and foods threatening global human health. Prior work applied the Gutzeit method and X-ray fluorescence spectroscopy to quantify inorganic arsenic based on a harmful chemical, i.e., mercury bromide, to capture the arsine gas. In this project, we explored silver nitrate as an alternative to mercury bromide for the capture and detection of inorganic arsenic. To compare the performance of mercury bromide and silver nitrate, two standard curves were established in the range from 0 to 33.3 µg/L after optimization of reaction conditions such as the quantity of reagents and reaction time. Our result shows silver nitrate-based standard curve had a lower limit of detection and limit of quantification at 1.02 µg/L and 3.40 µg/L, respectively, as compared to the one built upon mercury bromide that has limit of detection of 4.86 µg/L and limit of quantification of 16.2 µg/L. The relative higher sensitivity when using silver nitrate was contributed by the less interfering elements for X-ray fluorescence analysis and thus lower background signals. A commercial apple juice was studied for matrix inference, and the results show 85%–99% recoveries and 7.4%–24.5% relative standard deviation. In conclusion, we demonstrated silver nitrate is a better choice in terms of safety restrictions and detection capability at lower inorganic arsenic concentrations.</p>","PeriodicalId":93411,"journal":{"name":"Analytical science advances","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2022-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://chemistry-europe.onlinelibrary.wiley.com/doi/epdf/10.1002/ansa.202200014","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical science advances","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ansa.202200014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Inorganic arsenic is a carcinogen repeatedly found in water and foods threatening global human health. Prior work applied the Gutzeit method and X-ray fluorescence spectroscopy to quantify inorganic arsenic based on a harmful chemical, i.e., mercury bromide, to capture the arsine gas. In this project, we explored silver nitrate as an alternative to mercury bromide for the capture and detection of inorganic arsenic. To compare the performance of mercury bromide and silver nitrate, two standard curves were established in the range from 0 to 33.3 µg/L after optimization of reaction conditions such as the quantity of reagents and reaction time. Our result shows silver nitrate-based standard curve had a lower limit of detection and limit of quantification at 1.02 µg/L and 3.40 µg/L, respectively, as compared to the one built upon mercury bromide that has limit of detection of 4.86 µg/L and limit of quantification of 16.2 µg/L. The relative higher sensitivity when using silver nitrate was contributed by the less interfering elements for X-ray fluorescence analysis and thus lower background signals. A commercial apple juice was studied for matrix inference, and the results show 85%–99% recoveries and 7.4%–24.5% relative standard deviation. In conclusion, we demonstrated silver nitrate is a better choice in terms of safety restrictions and detection capability at lower inorganic arsenic concentrations.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用Gutzeit法和x射线荧光光谱法检测无机砷的绿色方法
无机砷是一种反复存在于水和食物中的致癌物,威胁着全球人类的健康。先前的工作应用了Gutzeit方法和x射线荧光光谱法,以有害化学品(即溴化汞)为基础定量无机砷,以捕获砷气体。在这个项目中,我们探索了硝酸银作为溴化汞的替代品,用于捕获和检测无机砷。为了比较溴化汞和硝酸银的性能,在0 ~ 33.3µg/L范围内,通过优化试剂用量和反应时间等条件,建立了两条标准曲线。结果表明,硝酸银标准曲线的检测下限为1.02µg/L,定量下限为3.40µg/L,溴化汞标准曲线的检测下限为4.86µg/L,定量下限为16.2µg/L。使用硝酸银时相对较高的灵敏度是由于x射线荧光分析的干扰元素较少,从而降低了背景信号。以市售苹果汁为研究对象进行矩阵推理,回收率为85% ~ 99%,相对标准偏差为7.4% ~ 24.5%。总之,我们证明了在较低无机砷浓度下,从安全限制和检测能力来看,硝酸银是更好的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.60
自引率
0.00%
发文量
0
期刊最新文献
Emerging Scientists in Analytical Sciences: Zhuoheng Zhou Sensitive and Cost-Effective Tools in the Detection of Ovarian Cancer Biomarkers Preprocessing of spectroscopic data to highlight spectral features of materials Bioactive Potential of the Sulfated Exopolysaccharides From the Brown Microalga Halamphora sp.: Antioxidant, Antimicrobial, and Antiapoptotic Profiles Effect of orange fruit peel extract concentration on the synthesis of zinc oxide nanoparticles
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1