Identifying Hypocalcemia in Dairy Cattle by Combining 3D Printing and Paper Diagnostics

Art Matthew Mamaril, Dalton L. Glasco, F. L. Leal Yepes, J. G. Bell
{"title":"Identifying Hypocalcemia in Dairy Cattle by Combining 3D Printing and Paper Diagnostics","authors":"Art Matthew Mamaril, Dalton L. Glasco, F. L. Leal Yepes, J. G. Bell","doi":"10.1149/2754-2726/aca034","DOIUrl":null,"url":null,"abstract":"This paper describes the design, fabrication, and validation of a paper-based diagnostic device for the rapid diagnosis of hypocalcemia in dairy cattle at the point-of-care (POC). The device incorporates a 3D printed calcium ion-selective membrane (ISM) as the sensing element for free—unbound—calcium in real bovine whole blood samples. With a linear response range of 100 mM to 97.7 μM, the sensor covers the clinically relevant concentrations of Ca2+ associated with both healthy cattle as well as those suffering from hypocalcemia. The components of the Ca2+ ion-selective electrodes were successfully translated to a paper-based device to provide a sensing platform that is simple to use, disposable, and low-cost, and is therefore well-situated for applications at the POC. The paper-based calcium sensor showed a Nernstian response between 10 mM and 100 μM and required only 12 μl of sample to perform a measurement, which can be accomplished in less than two minutes without the need for time-consuming separation steps. The performance of the paper-based Ca2+ sensor was validated using the commercially available epoc® Blood Analysis System, which provided results within 5% of the data obtained with 3D printed Ca2+-ISM integrated paper-based device.","PeriodicalId":72870,"journal":{"name":"ECS sensors plus","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ECS sensors plus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1149/2754-2726/aca034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper describes the design, fabrication, and validation of a paper-based diagnostic device for the rapid diagnosis of hypocalcemia in dairy cattle at the point-of-care (POC). The device incorporates a 3D printed calcium ion-selective membrane (ISM) as the sensing element for free—unbound—calcium in real bovine whole blood samples. With a linear response range of 100 mM to 97.7 μM, the sensor covers the clinically relevant concentrations of Ca2+ associated with both healthy cattle as well as those suffering from hypocalcemia. The components of the Ca2+ ion-selective electrodes were successfully translated to a paper-based device to provide a sensing platform that is simple to use, disposable, and low-cost, and is therefore well-situated for applications at the POC. The paper-based calcium sensor showed a Nernstian response between 10 mM and 100 μM and required only 12 μl of sample to perform a measurement, which can be accomplished in less than two minutes without the need for time-consuming separation steps. The performance of the paper-based Ca2+ sensor was validated using the commercially available epoc® Blood Analysis System, which provided results within 5% of the data obtained with 3D printed Ca2+-ISM integrated paper-based device.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
3D打印与纸质诊断相结合识别奶牛低钙血症
本文介绍了一种纸基诊断装置的设计、制造和验证,用于在护理点快速诊断奶牛低钙血症(POC)。该设备包含一个3D打印的钙离子选择性膜(ISM),作为真实牛全血样本中游离-未结合钙的传感元件。该传感器的线性响应范围为100 mM至97.7μM,涵盖了健康牛和低钙血症牛的临床相关Ca2+浓度。Ca2+离子选择性电极的成分被成功地转化为纸基设备,以提供一种使用简单、一次性和低成本的传感平台,因此非常适合在POC应用。纸基钙传感器显示出在10mM和100μM之间的能斯特响应,并且只需要12μl样品就可以进行测量,这可以在不到两分钟的时间内完成,而不需要耗时的分离步骤。纸基Ca2+传感器的性能使用市售的epoc®血液分析系统进行了验证,该系统提供的结果在3D打印Ca2+-ISM集成纸基设备获得的数据的5%以内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Portable Dynamic Laser Speckle Imaging for Rapid Antimicrobial Susceptibility Testing. Review—Energy and Power Requirements for Wearable Sensors 3D Printed Carbon Nanotubes Reinforced Polydimethylsiloxane Flexible Sensors for Tactile Sensing Editors’ Choice—Review—Advances in Electrochemical Sensors: Improving Food Safety, Quality, and Traceability Field Testing of a Mixed Potential IoT Sensor Platform for Methane Quantification
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1